CLC/TS 50502:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Railway applications - Rolling stock - Electric equipment in trolley buses - Safety requirements and connection systems
10-03-2023
30-07-2008
1 General
1.1 Scope
1.2 Normative references
1.3 Definitions
1.4 Voltages
1.5 Classification of the voltage bands
2 Trolley bus construction
2.1 Protection and electrical safety criteria
2.2 Electrical components in band III voltage (high voltage)
2.3 Electric traction equipment
2.4 Emergency running equipment (independent from OHL)
2.5 Electrical components in band II voltage (medium voltage)
2.6 Electrical components in band I voltage (low voltage)
3 Checks and tests
3.1 General
3.2 New trolley-vehicles
3.3 Overhauled trolley-vehicles
3.4 On-duty trolley vehicles (periodical checks)
3.5 Leakage detectors
Annex A (normative) Constructional detailed provisions
Annex B (normative) Trolley buses - Connection system to
overhead contact lines
Annex C (normative) Constructional hints for connection systems
Bibliography
This Technical Specification applies to electrical systems on board trolley buses, as defined in 1.3.1, fed with a nominal line voltage (Un) between 600 V d.c. and 750 V d.c. This Technical Specification defines the requirements and constructional hints, especially to avoid danger of electrical kind to the public and to the personnel. CLC/TS 50502 is normative only for vehicles ordered and designed after publication of the same. This Technical Specification covers vehicles intended for public transport of persons. It refers mainly to earthed networks, but reference is made also to galvanically insulated networks. Annexes B and C are related to the connection systems. The detailed scope of these annexes is given in Annex B.
Committee |
CLC/TC 9X
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
VDE V 0115-502 : 2009 | Identical |
DIN CLC/TS 50502 : 2009 | Identical |
I.S. CLC TS 50502:2007 | Identical |
DD CLC/TS 50502:2008 | Identical |
NEN NPR CLC/TS 50502 : 2008 | Identical |
CEI CLC/TS 50502 : 2009 | Identical |
S.R. CLC/TS 50502:2008 | Identical |
BS EN 50119 : 2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
11/30215604 DC : 0 | BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
I.S. EN 50119:2009 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
I.S. EN 50119:2020 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60349-1:2010 | Electric traction - Rotating electrical machines for rail and road vehicles - Part 1: Machines other than electronic converter-fed alternating current motors |
EN 60349-1:2010 | Electric traction - Rotating electrical machines for rail and road vehicles - Part 1: Machines other than electronic converter-fed alternating current motors |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60322:2001 | Railway applications - Electric equipment for rolling stock - Rules for power resistors of open construction |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
EN 50207:2000 | Railway applications - Electronic power converters for rolling stock |
ISO 10099:2001 | Pneumatic fluid power — Cylinders — Final examination and acceptance criteria |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
EN 50215:2009 | Railway applications - Rolling stock - Testing of rolling stock on completion of construction and before entry into service |
IEC 60349-2:2010 | Electric traction - Rotating electrical machines for rail and road vehicles - Part 2: Electronic converter-fed alternating current motors |
EN 60349-2:2010 | ELECTRIC TRACTION - ROTATING ELECTRICAL MACHINES FOR RAIL AND ROAD VEHICLES - PART 2: ELECTRONIC CONVERTER-FED ALTERNATING CURRENT MOTORS |
EN 50155:2017 | Railway applications - Rolling stock - Electronic equipment |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
ISO 9001:2015 | Quality management systems — Requirements |
EN 60322:2001 | Railway applications - Electric equipment for rolling stock - Rules for power resistors of open construction |
EN 50272-3 : 2002 COR 2003 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 3: TRACTION BATTERIES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.