CSA C22.2 NO. 60601-1-3:09 (R2019)

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral standard: Radiation protection in diagnostic X-ray equipment (Adopted IEC 60601-1:2008, second edition, 2008-01) | Appareils électromédicaux - Partie 1-3: Exigences générales pour la sécurité de base et les performances essentielles - Norme collatérale: Radioprotection dans les appareils à rayonnement X de diagnostic (norme IEC 60601-1:2008 adoptée, deuxième édition, 2008-01)

Available format(s)

Hardcopy , PDF

Superseded date

16-11-2019

Language(s)

English - French

Published date

01-01-2009

€207.28
Excluding VAT

CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-1-3, Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-3 (second edition, 2008-01). It supersedes the previous edition published in 1998 as CAN/CSA-C22.2 No. 601.1.3 (adopted CEI/IEC 601-1-3:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope, object and related standards 1.1 Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to X-RAY EQUIPMENT and to subassemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process. This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only. Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-1-3, Appareils électromédicaux - Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles - Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic. Il s\'agit de l\'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-1-3 (deuxième édition, 2008-01), qui porte le même titre. Cette norme remplace l\'édition précédente publiée en 1998 qui portait la désignation CAN/CSA-C22.2 nº 601.1.3 (norme CEI/IEC 601-1-3:1994 adoptée). Cette norme fait partie d\'une série de normes publiées par CSA lesquelles constituent le Code canadien de l\'électricité, Deuxième partie. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application, objet et normes connexes 1.1 Domaine d\'application La présente norme internationale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS et SYSTEMES EM. La présente norme collatérale s\'applique aux APPAREILS A RAYONNEMENT X et à leurs sousensembles, dont les IMAGES RADIOLOGIQUES d\'un PATIENT humain sont utilisées à des fins de diagnostic, de planification ou de guide pour les procédures médicales. 1.2 Objet La présente Norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes Particulières. L\'objet de la présente norme collatérale est d\'établir des exigences générales pour la protection contre les RAYONNEMENTS X dans les APPAREILS A RAYONNEMENT X, afin que l\'IRRADIATION des PATIENTS humains, de l\'OPERATEUR, des membres de l\'équipe médicale et des autres personnes présentes puisse être maintenue à un niveau aussi bas que raisonnablement possible, sans compromettre le bénéfice de la procédure RADIOLOGIQUE. Des normes particulières peuvent spécifier des valeurs et/ou mesures qui leur sont appropriées par rapport aux exigences générales spécifiées dans la présente norme collatérale. La mise en oeuvre des exigences générales ou, à la place, la référence à la norme particulière doit être justifiée dans le processus DE GESTION DES RISQUES. La présente norme collatérale traite des aspects de RADIOPROTECTION liés aux RAYONNEMENTS X uniquement. Les exigences pour la commande de l\'énergie électrique utilisée pour produire le RAYONNEMENT X, qui est aussi un aspect important de la RADIOPROTECTION, figurent dans la CEI 60601-1 et dans les normes particulières pour la sécurité et les PERFORMANCES ESSENTIELLES des APPAREILS concernés.

DocumentType
Standard
ISBN
978-1-55491-261-2
Pages
121
ProductNote
THIS STANDARD ALSO REFERS TO CEI 60878.
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy
Supersedes

CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-1-3, Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-3 (second edition, 2008-01). It supersedes the previous edition published in 1998 as CAN/CSA-C22.2 No. 601.1.3 (adopted CEI/IEC 601-1-3:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope, object and related standards 1.1 Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to X-RAY EQUIPMENT and to subassemblies of such equipment, where RADIOLOGICAL IMAGES of a human PATIENT are used for diagnosis, planning or guidance of medical procedures. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. The object of this collateral standard is to establish general requirements for protection against X-RADIATION in X-RAY EQUIPMENT, in order that the IRRADIATION of the human PATIENT, the OPERATOR, staff and members of the public can be kept as low as reasonably achievable, without jeopardizing the benefit of the RADIOLOGICAL procedure. Particular standards may specify their appropriate values and/or measures for general requirements specified in this collateral standard. The implementation of the general requirements or the reference to the particular standard instead, shall be justified in the RISK MANAGEMENT process. This collateral standard considers RADIATION PROTECTION aspects related to X-RADIATION only. Requirements for the control of the electrical energy used to generate X-RADIATION, which is also an important aspect of RADIATION PROTECTION, are included in IEC 60601-1 and in particular standards for the safety and ESSENTIAL PERFORMANCE of the EQUIPMENT concerned. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-1-3, Appareils électromédicaux - Partie 1-3 : Exigences générales pour la sécurité de base et les performances essentielles - Norme collatérale : Radioprotection dans les appareils à rayonnement X de diagnostic. Il s\'agit de l\'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-1-3 (deuxième édition, 2008-01), qui porte le même titre. Cette norme remplace l\'édition précédente publiée en 1998 qui portait la désignation CAN/CSA-C22.2 nº 601.1.3 (norme CEI/IEC 601-1-3:1994 adoptée). Cette norme fait partie d\'une série de normes publiées par CSA lesquelles constituent le Code canadien de l\'électricité, Deuxième partie. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application, objet et normes connexes 1.1 Domaine d\'application La présente norme internationale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS et SYSTEMES EM. La présente norme collatérale s\'applique aux APPAREILS A RAYONNEMENT X et à leurs sousensembles, dont les IMAGES RADIOLOGIQUES d\'un PATIENT humain sont utilisées à des fins de diagnostic, de planification ou de guide pour les procédures médicales. 1.2 Objet La présente Norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes Particulières. L\'objet de la présente norme collatérale est d\'établir des exigences générales pour la protection contre les RAYONNEMENTS X dans les APPAREILS A RAYONNEMENT X, afin que l\'IRRADIATION des PATIENTS humains, de l\'OPERATEUR, des membres de l\'équipe médicale et des autres personnes présentes puisse être maintenue à un niveau aussi bas que raisonnablement possible, sans compromettre le bénéfice de la procédure RADIOLOGIQUE. Des normes particulières peuvent spécifier des valeurs et/ou mesures qui leur sont appropriées par rapport aux exigences générales spécifiées dans la présente norme collatérale. La mise en oeuvre des exigences générales ou, à la place, la référence à la norme particulière doit être justifiée dans le processus DE GESTION DES RISQUES. La présente norme collatérale traite des aspects de RADIOPROTECTION liés aux RAYONNEMENTS X uniquement. Les exigences pour la commande de l\'énergie électrique utilisée pour produire le RAYONNEMENT X, qui est aussi un aspect important de la RADIOPROTECTION, figurent dans la CEI 60601-1 et dans les normes particulières pour la sécurité et les PERFORMANCES ESSENTIELLES des APPAREILS concernés.

Standards Relationship
IEC 60601-1-3:2008+AMD1:2013 CSV Identical