CSA C61869-6:20
Current
The latest, up-to-date edition.
Instrument transformers — Part 6: Additional general requirements for low-power instrument transformers (Adopted IEC 61869-6:2016, first edition, 2016-04, with Canadian deviations) | Transformateurs de mesure — Partie 6 : Exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance (norme IEC 61869-6:2016 adoptée, première édition, 2016-04, avec exigences propres au Canada)
Hardcopy , PDF
English - French
01-01-2020
CSA Preface This is the first edition of CSA C61869-6, Instrument transformers — Part 6: Additional general requirements for low-power instrument transformers, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61869-6 (first edition, 2016-04). It replaces relevant parts of CAN/CSA-C60044-7:07 (adopted IEC 60044-7:1999), Instrument transformers — Part 7: Electronic voltage transformers, and of CAN/CSA-C60044-8:07 (adopted IEC 60044-8:2002), Instrument transformers — Part 8: Electronic current transformers. It is part of the CSA C61869 series of Standards on instrument transformers, which consists of adoptions with Canadian deviations of the IEC 61869 series of Standards. This Standard is intended to be used in conjunction with CAN/CSA-C61869-1:14, Instrument transformers — Part 1: General requirements (adopted IEC 61869-1:2007, with Canadian deviations). Requirements common to all instrument transformer types are grouped in CAN/CSA-C61869-1. Requirements specific to conventional instrument transformer types are grouped in CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4, and CAN/CSA-C61869-5. Those CSA Group Standards present many inherited Canadian deviations justified by the specific conditions, practices, and regulations in Canada. Requirements common to low-power instrument transformers (LPIT) used for ac applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV, and EHV or used for dc applications are grouped in CSA C61869-6. The remaining Standards in the series state requirements for specific types of instrument transformers. Canada has actively participated in the development of IEC 61869-6, in order to enforce specific Canadian conditions. It should be noted that Parts 6 to 13 of the IEC 61869 series specify the requirements for ac LPIT as well as the interfaces necessary to implement the LPIT into an integrated system for protection and measurement. Such a system uses a universal digital transmission protocol compatible with IEC 61850, and has a digital output. In order to ensure full interoperability, Canadian deviations in CSA C61869-6 are minimal. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61869 is a product family standard and covers only additional general requirements for low-power instrument transformers (LPIT) used for a.c. applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV and EHV or used for d.c. applications. This product standard is based on IEC 61869-1:2007, in addition to the relevant product specific standard. This part of IEC 61869 does not cover the specification for the digital output format of instrument transformers. This part of IEC 61869 defines the errors in case of analogue or digital output. The other characteristics of the digital interface for instrument transformers are standardised in IEC 61869-9 as an application of the standards, the IEC 61850 series, which details layered substation communication architecture. This part of IEC 61869 considers additional requirements concerning bandwidth. The accuracy requirements on harmonics and requirements for the anti-aliasing filter are given in the normative Annex 6A.4. The general block diagram of single-phase LPITs is given in Figure 601. According to the technology, it is not absolutely necessary that all parts described in Figure 601 are included in the instrument transformer. As an example, for low-power passive transformers (LPITs without active electronic components) the blocks are composed only with passive components and there is no power supply. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de CSA C61869-6, Transformateurs de mesure — Partie 6 : Exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61869-6 (première édition, 2016-04), qui porte le même titre. Il remplace les parties pertinentes de CAN/CSA-C60044-7:07 (norme IEC 60044-7:1999 adoptée), Transformateurs de mesure — Partie 7 : Transformateurs de tension électroniques, et de CAN/CSA-C60044-8:07 (norme IEC 60044-8:2002 adoptée), Instrument transformers — Part 8: Electronic current transformers. Il fait partie de la série de normes CSA C61869 sur les transformateurs de mesure, laquelle est constituée de l’adoption, avec exigences propres au Canada, des normes de la série IEC 61869. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C61869-1:14, Transformateurs de mesure — Partie 1 : Exigences générales (norme IEC 61869-1:2007 adoptée, avec exigences propres au Canada). Les exigences qui s’appliquent à tous les types de transformateurs de mesure sont regroupées dans CAN/CSA-C61869-1. Les exigences propres aux types de transformateur de mesure conventionnels sont regroupées dans CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4 et CAN/CSA-C61869-5. Ces normes de Groupe CSA présentent de nombreuses exigences propres au Canada hérités justifiés par les conditions, pratiques et règlements particuliers du Canada. Les exigences qui s’appliquent aux transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu, sont regroupées dans CSA C61869-6. Les autres normes de la série énoncent des exigences particulières aux types spécifiques de transformateurs de mesure. Le Canada a participé activement à la rédaction d’IEC 61869-6 pour que soient prises en compte les conditions propres au Canada. Il convient de noter que les parties 6 à 13 de la série IEC 61869 spécifient les exigences visant le LPIT à courant alternatif ainsi que les interfaces nécessaires pour mettre en oeuvre le LPIT dans un système intégré utilisés pour la protection et la mesure. Un tel système utilise un protocole de transmission numérique universel compatible avec IEC 61850, et a une sortie numérique. Afin que soit assurée la pleine interopérabilité, les exigences propres au Canada dans CSA C61869-6 sont minimes. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente Partie de l\'IEC 61869 est une norme de familles de produits et couvre uniquement les exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu. La présente norme de produit s\'appuie sur l\'IEC 61869-1:2007, en plus de la norme correspondante spécifique au produit. La présente partie de l\'IEC 61869 ne couvre pas la spécification du format de sortie numérique des transformateurs de mesure. La présente partie de l\'IEC 61869 définit les erreurs pour les sorties analogiques et numériques. Les autres caractéristiques de l\'interface numérique des transformateurs de mesure sont normalisées dans l\'IEC 61869-9 en tant qu\'application des normes de la série IEC 61850, qui décrit en détail une architecture de communication en couches applicable aux postes électriques. La présente partie de l\'IEC 61869 tient compte des exigences supplémentaires relatives à la largeur de bande. Les exigences de précision relatives aux harmoniques et les exigences de filtre antirepliement sont données à l\'Annexe normative 6A.4. Le diagramme général des transformateurs de mesure de faible puissance (LPIT) monophasés est donné à la Figure 601. En fonction de la technologie, il n\'est pas absolument nécessaire d\'inclure toutes les parties décrites à la Figure 601 dans le transformateur de mesure. Par exemple, pour les transformateurs passifs de faible puissance (LPIT sans composants électroniques actifs), les blocs sont uniquement composés de composants passifs, sans alimentation électrique.
DocumentType |
Standard
|
ISBN |
978-1-4883-2758-2
|
Pages |
202
|
ProductNote |
THIS STANDARD IS ALSO REFERS TO IEC 61869-7, IEC 61869-8
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
CSA Preface This is the first edition of CSA C61869-6, Instrument transformers — Part 6: Additional general requirements for low-power instrument transformers, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61869-6 (first edition, 2016-04). It replaces relevant parts of CAN/CSA-C60044-7:07 (adopted IEC 60044-7:1999), Instrument transformers — Part 7: Electronic voltage transformers, and of CAN/CSA-C60044-8:07 (adopted IEC 60044-8:2002), Instrument transformers — Part 8: Electronic current transformers. It is part of the CSA C61869 series of Standards on instrument transformers, which consists of adoptions with Canadian deviations of the IEC 61869 series of Standards. This Standard is intended to be used in conjunction with CAN/CSA-C61869-1:14, Instrument transformers — Part 1: General requirements (adopted IEC 61869-1:2007, with Canadian deviations). Requirements common to all instrument transformer types are grouped in CAN/CSA-C61869-1. Requirements specific to conventional instrument transformer types are grouped in CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4, and CAN/CSA-C61869-5. Those CSA Group Standards present many inherited Canadian deviations justified by the specific conditions, practices, and regulations in Canada. Requirements common to low-power instrument transformers (LPIT) used for ac applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV, and EHV or used for dc applications are grouped in CSA C61869-6. The remaining Standards in the series state requirements for specific types of instrument transformers. Canada has actively participated in the development of IEC 61869-6, in order to enforce specific Canadian conditions. It should be noted that Parts 6 to 13 of the IEC 61869 series specify the requirements for ac LPIT as well as the interfaces necessary to implement the LPIT into an integrated system for protection and measurement. Such a system uses a universal digital transmission protocol compatible with IEC 61850, and has a digital output. In order to ensure full interoperability, Canadian deviations in CSA C61869-6 are minimal. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61869 is a product family standard and covers only additional general requirements for low-power instrument transformers (LPIT) used for a.c. applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV and EHV or used for d.c. applications. This product standard is based on IEC 61869-1:2007, in addition to the relevant product specific standard. This part of IEC 61869 does not cover the specification for the digital output format of instrument transformers. This part of IEC 61869 defines the errors in case of analogue or digital output. The other characteristics of the digital interface for instrument transformers are standardised in IEC 61869-9 as an application of the standards, the IEC 61850 series, which details layered substation communication architecture. This part of IEC 61869 considers additional requirements concerning bandwidth. The accuracy requirements on harmonics and requirements for the anti-aliasing filter are given in the normative Annex 6A.4. The general block diagram of single-phase LPITs is given in Figure 601. According to the technology, it is not absolutely necessary that all parts described in Figure 601 are included in the instrument transformer. As an example, for low-power passive transformers (LPITs without active electronic components) the blocks are composed only with passive components and there is no power supply. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de CSA C61869-6, Transformateurs de mesure — Partie 6 : Exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61869-6 (première édition, 2016-04), qui porte le même titre. Il remplace les parties pertinentes de CAN/CSA-C60044-7:07 (norme IEC 60044-7:1999 adoptée), Transformateurs de mesure — Partie 7 : Transformateurs de tension électroniques, et de CAN/CSA-C60044-8:07 (norme IEC 60044-8:2002 adoptée), Instrument transformers — Part 8: Electronic current transformers. Il fait partie de la série de normes CSA C61869 sur les transformateurs de mesure, laquelle est constituée de l’adoption, avec exigences propres au Canada, des normes de la série IEC 61869. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C61869-1:14, Transformateurs de mesure — Partie 1 : Exigences générales (norme IEC 61869-1:2007 adoptée, avec exigences propres au Canada). Les exigences qui s’appliquent à tous les types de transformateurs de mesure sont regroupées dans CAN/CSA-C61869-1. Les exigences propres aux types de transformateur de mesure conventionnels sont regroupées dans CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4 et CAN/CSA-C61869-5. Ces normes de Groupe CSA présentent de nombreuses exigences propres au Canada hérités justifiés par les conditions, pratiques et règlements particuliers du Canada. Les exigences qui s’appliquent aux transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu, sont regroupées dans CSA C61869-6. Les autres normes de la série énoncent des exigences particulières aux types spécifiques de transformateurs de mesure. Le Canada a participé activement à la rédaction d’IEC 61869-6 pour que soient prises en compte les conditions propres au Canada. Il convient de noter que les parties 6 à 13 de la série IEC 61869 spécifient les exigences visant le LPIT à courant alternatif ainsi que les interfaces nécessaires pour mettre en oeuvre le LPIT dans un système intégré utilisés pour la protection et la mesure. Un tel système utilise un protocole de transmission numérique universel compatible avec IEC 61850, et a une sortie numérique. Afin que soit assurée la pleine interopérabilité, les exigences propres au Canada dans CSA C61869-6 sont minimes. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente Partie de l\'IEC 61869 est une norme de familles de produits et couvre uniquement les exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu. La présente norme de produit s\'appuie sur l\'IEC 61869-1:2007, en plus de la norme correspondante spécifique au produit. La présente partie de l\'IEC 61869 ne couvre pas la spécification du format de sortie numérique des transformateurs de mesure. La présente partie de l\'IEC 61869 définit les erreurs pour les sorties analogiques et numériques. Les autres caractéristiques de l\'interface numérique des transformateurs de mesure sont normalisées dans l\'IEC 61869-9 en tant qu\'application des normes de la série IEC 61850, qui décrit en détail une architecture de communication en couches applicable aux postes électriques. La présente partie de l\'IEC 61869 tient compte des exigences supplémentaires relatives à la largeur de bande. Les exigences de précision relatives aux harmoniques et les exigences de filtre antirepliement sont données à l\'Annexe normative 6A.4. Le diagramme général des transformateurs de mesure de faible puissance (LPIT) monophasés est donné à la Figure 601. En fonction de la technologie, il n\'est pas absolument nécessaire d\'inclure toutes les parties décrites à la Figure 601 dans le transformateur de mesure. Par exemple, pour les transformateurs passifs de faible puissance (LPIT sans composants électroniques actifs), les blocs sont uniquement composés de composants passifs, sans alimentation électrique.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.