SUPPLEMENT NO. 2 TO CAN/CSA-Z98-01 - PASSENGER ROPEWAYS AND CONVEYORS
01-11-2007
12-01-2013
Technical Committee on Passenger Ropeways
Preface
1. Scope
1.1 General
1.2 Equipment Covered
1.3 Freight
1.4 Existing Installations
1.5 Exceptions
1.6 Funicular Railways
1.7 Mandatory and Advisory Rules
2. Reference Publications and Definitions
2.1 Reference Publications
2.2 Definitions
3. General Requirements
3.1 Scope
3.2 Alterations
3.3 Location and Alignment
3.4 General Design Requirements
3.5 Materials, Manufacturing, and Quality Control
3.6 Fatigue Design
3.7 Corrosion Protection
3.8 Ropes and Chains
3.9 Welding
3.10 Buildings and Structures
3.11 Machine Rooms
3.12 Internal Combustion Engines
3.13 Hydraulic Systems
3.14 Foundations
3.15 Speed, Capacity, and Spacing
3.16 Crossing Ropeways
3.17 Wind Gauges
3.18 Towers and Equipment
3.19 Line Sheaves and Sheave Assemblies
3.20 Counterweight Sheaves
3.21 Drive and Return Sheaves
3.22 Tension Systems
3.23 Drive Systems
3.24 Brakes and Antirollback Device
3.25 Protection in Stations
3.26 Loading and Unloading Areas
3.27 Carriers
3.28 Rope Grips
3.29 Controls
3.30 Electrical
3.31 Communications
3.32 Signs
3.33 Fire Protection
3.34 Lighting
3.35 Avalanche Control
3.36 Manuals
4. Reversible Passenger Ropeways
4.1 Scope
4.2 General Cabin Clearances
4.3 Vertical Clearances
4.4 Horizontal Clearances
4.5 Wind Force
4.6 Towers and Track Rope Saddles
4.7 Haul Rope Guides
4.8 Cabin Guides to Limit Cabin Swing
4.9 Sheaves - Track Rope to Counterweight
4.10 Drives
4.11 Braking Systems
4.12 Systems with Track Rope Brakes
4.13 Systems with No Track Rope Brakes on Two Track Ropes
per Track
4.14 Friction of the Haul Rope on the Drive Bullwheel
4.15 Carriages
4.16 Cabin Hanger
4.17 Cabins
4.18 Loading and Unloading Areas
4.19 Controls
4.20 Communications
4.21 Evacuation
5. Circulating Passenger Ropeways
5.1 Scope
5.2 Speed
5.3 Vertical Clearances
5.4 Horizontal Clearances
5.5 Ski Tip Deflectors
5.6 Braking Systems
5.7 Loading and Unloading Areas
5.8 Bullwheel Unloading
5.9 Intermediate Stations
5.10 Foot Passengers
5.11 Enclosed Passenger Cabins
5.12 Chairs
5.13 Detachable Grip Ropeways
5.14 Safety Gates
5.15 Haul Rope Retention (Bicable Systems)
5.16 Towers and Track Rope Saddles
5.17 Sheaves Track Rope to Counterweight
5.18 Track Rope Carriage
5.19 Haul Rope Guides (Bicable Systems)
6. Surface Passenger Ropeways
6.1 Scope
6.2 Tow Path
6.3 Carrier Interval
6.4 Location and Height of Towers
6.5 Tower Clearance
6.6 Drive and Return Sheaves
6.7 Brakes
6.8 Antirollback Device
6.9 Safety Gate
6.10 Loading and Unloading Areas
6.11 Carrier Length
7. Rope Tows
7.1 Scope
7.2 Tow Path
7.3 Capacity and Speed
7.4 Vertical Clearances
7.5 Horizontal Clearances
7.6 Clearances Between Uphill and Downhill Ropes
7.7 Vertical Forces
7.8 Towers
7.9 Haul Rope Retention
7.10 Loading Sheaves
7.11 Control of Rope Rotation
7.12 Guides
7.13 Brakes
7.14 Antirollback Device
7.15 Safety Gate
7.16 Towing Outfits
7.17 Drive Controls
8. Ropeways for Secondary Carriers
8.1 Scope
8.2 Tow Path
8.3 Capacity
8.4 Rope Speed
8.5 Vertical Clearances
8.6 Horizontal Clearances
8.7 Vertical Forces
8.8 Towers
8.9 Haul Rope Retention
8.10 Loading Sheaves
8.11 Control of Rope Rotation
8.12 Guides
8.13 Brakes
8.14 Safety Gate
8.15 Towing Attachments
8.16 Drive Controls
8.17 Cable Tension
9. Conveyors
9.1 Purpose
9.2 Conveyor Path
9.3 Capacity and Speed
9.4 Clearances
9.5 Line Equipment
9.6 Brakes, Rollback Device, and Automatic Stopping
Devices
9.7 Drive
9.8 Drive Controls
9.9 Loading and Unloading Areas
9.10 Tensioning
9.11 Belt Enclosures
10. Ropes and Chains
10.1 Fibre Ropes
10.2 Wire Ropes
10.3 Wire Rope Construction
10.4 Track Ropes
10.5 Guy Ropes
10.6 Testing
10.7 Splices
10.8 End Connections
10.9 Chain
11. Inspection, Testing, Operation, and Maintenance of
Passenger Ropeways
11.1 Scope
11.2 Personnel Training
11.3 Operational Requirements
11.4 Operations Manual
11.5 Minimum Number and Location of Operating Personnel
11.6 Operational Procedures and Rules
11.7 Hazardous Conditions
11.8 Communication
11.9 Stations
11.10 Loading and Unloading Stations
11.11 Starting and Stopping Ropeways
11.12 Operational Inspection
11.13 Manual Transmissions
11.14 Tension and Carriage Systems
11.15 Evacuation with Evacuation Drive
11.16 Manual Evacuation
11.17 Termination of Daily Operations
11.18 Operational Log
11.19 Maintenance Safety Procedures
11.20 Grounding
11.21 Maintenance Procedures
11.22 Replacement Components
11.23 Maintenance Requirements
11.24 Maintenance Log
11.25 Acceptance Tests and Inspection
11.26 Periodic Load Testing
11.27 Nondestructive Testing of Ropes, Sleeves, and Sockets
11.28 Wire Rope Maintenance
11.29 Protruding Broken Wires
11.30 Replacement or Repair of Wire Rope
11.31 Locked Coil Track-Rope Broken Wires
11.32 Wire Rope Log
11.33 Splice Certificate
11.34 Chains in Tension Systems
11.35 Nondestructive Tests of Carriers on Above-Surface
Ropeways
11.36 First Aid
11.37 Fire Protection
Tables
Appendices
A - Approval Checklist
B - Procedures for Work Carriers
C - Daily Ropeway Log
D - Inspection and Maintenance Checklist
E - Rope Nondestructive Test Report
F - Grip-Carrier Nondestructive Test Report
G - Certificate and Inspection of Wire Rope Splice
H - Five-Year Load Test Report
J - Stopping Times and Distances for Circulating Passenger
Ropeways
K - Example of Cast Socket Report
Index
DevelopmentNote |
This is a supplement to CSA Z98. (11/2004)
|
DocumentType |
Standard
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.