GLASS IN BUILDING - INSULATING GLASS UNITS - PART 3: LONG TERM TEST METHOD AND REQUIREMENTS FOR GAS LEAKAGE RATE AND FOR GAS CONCENTRATION TOLERANCES
Hardcopy , PDF
07-03-2021
English, German
01-01-2003
Foreword
1 Scope
2 Normative references
3 Terms and definitions and symbols
4 Requirements
4.1 Gas leakage rate
4.2 Tolerances on gas concentration
4.3 Dew point and moisture penetration index
4.4 Edge seal strength
4.5 Additional requirements for other gases than argon,
sulfurhexafluoride and air
5 Testing
5.1 Principle of testing
5.2 Apparatus
5.2.1 Climate exposure equipment
5.2.2 Container for gas leakage rate measurement
5.2.3 Gas analysis equipment
5.2.4 Gas sampling device
5.3 Test specimens
5.3.1 Preparation of test specimens
5.3.2 Number of test specimens
5.3.3 Construction and appearance
5.4 Procedure
5.4.1 Determination of internal volume of a test
specimen
5.4.2 Climate exposure
5.4.3 Measuring the gas leakage
5.4.4 Analysis of gas
5.5 Evaluation
6 Precision of test method
7 Test report
Annex A (normative) - Requirements for other gases
A.1 Durability of the gas and interaction with
insulating glass components
A.2 Effect on thermal- and sound insulation
A.3 Assessment example with krypton gas filling
Annex B (informative) - Relationship between artificial
and natural ageing with regard to thermal and
sound insulation
Annex C (informative) - Determination of the gas leakage
rate by gas chromatography
C.1 Principle of method
C.2 Equipment
C.2.1 Full container
C.2.2 Ring container
C.2.3 Cooling trap
C.2.4 Gas chromatograph
C.2.5 Connecting pieces
C.2.6 Solvents
C.2.7 Purging and carrier gas
C.2.8 Calibrating gas
C.3 Preparation of test specimens
C.4 Procedure
C.4.1 Connection of the apparatus
C.4.2 Installation of the test specimen
C.4.3 Temperature
C.4.4 Calibration
C.4.5 Measurement of the gas leakage
C.4.6 Blank test
C.4.7 Result
Bibliography
Defines insulating glass units, and ensures by means of an adequate evaluation of conformity to this standard that: - energy savings are made because the U-value and solar factor do not change significantly; - health is preserved because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.
DevelopmentNote |
Supersedes DIN 52293 E (09/2003)
|
DocumentType |
Standard
|
Pages |
27
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
Standards | Relationship |
ONORM EN 1279-3 : 2003 | Identical |
NBN EN 1279-3 : 2003 | Identical |
UNE-EN 1279-3:2003 | Identical |
I.S. EN 1279-3:2002 | Identical |
EN 1279-3:2002 | Identical |
UNI EN 1279-3 : 2004 | Identical |
NS EN 1279-3 : 1ED 2003 | Identical |
NF EN 1279-3 : 2003 | Identical |
SN EN 1279-3 : 2002 | Identical |
BS EN 1279-3:2002 | Identical |
NEN EN 1279-3 : 2002 | Identical |
PREN 1279-1 : DRAFT 95 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES AND DIMENSIONAL TOLERANCES |
EN 1279-6:2002 | Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 1279-4:2002 | Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals |
EN 1279-2:2002 | Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.