1 Scope
2 Normative references
3 Terms and definitions, symbols and units
3.1 Terms and definitions
3.2 Symbols and units
3.3 Subscripts
3.4 Superscripts
4 Geometrical character
4.1 Main principles
4.2 Developed areas and internal depth
4.3 Boundaries of curtain wall structures
4.3.1 General
4.3.2 Boundaries of a representative reference
element
4.3.3 Curtain wall areas
5 Cut-off planes and partitioning of thermal zones
5.1 Rules for thermal modelling
5.2 Cut-off planes of the geometrical model
6 Calculation of curtain wall transmittance
6.1 Methodologies
6.2 Single assessment method
6.2.1 Thermal transmittance of glazing units
and panels (filling elements)
6.2.2 Determination of the heat flow through filling
element/mullion or transom/filling element
connection
6.2.3 Determination of the overall thermal transmittance
of a curtain wall (U[cw])
6.3 Component assessment method
6.3.1 General
6.3.2 Definition of areas
6.3.3 Thermal transmittance of glazing units and panels
(filling elements)
6.3.4 Thermal transmittance of frames, mullions and
transoms
6.3.5 Linear thermal transmittance
6.4 Thermal transmittance of a curtain wall built of different
elements
7 Input data
8 Report
8.1 Section drawings
8.2 Overview drawing of the whole curtain wall element
8.3 Values used for calculation
8.4 Presentation of results
Annex A (informative) - Guidance for calculating the thermal
transmittance U[cw] of curtain walling using the
two methods
Annex B (informative) - Linear thermal transmittance of
junctions
Annex C (normative) - A method for calculating the thermal
effect of screws using a 2D numerical method and the
procedures specified in EN ISO 10077-2
C.1 General
C.2 Calculation of the equivalent thermal conductivity of
the screw [lambda][s,eq]
C.3 Consideration of screw heads and washers
Annex D (normative) - Ventilated and unventilated air spaces
Unventilated air layer
Annex E (informative) - Component method: Calculation example
E.1 Data for examples
E.2 Frames
E.2.1 Definition and evaluation of areas
E.2.2 Evaluation of U[f] values
E.3 Glazing units
E.3.1 Definition and evaluation of areas
E.3.2 Evaluation of U[g] values
E.3.3 Definition of l[g] and evaluation
of [psi][g], [psi][m,f] and [psi][t,f]
E.4 Panels
E.4.1 Definition and evaluation of areas
E.4.2 Evaluation of U[p] values
E.4.3 Definition of l[p] and evaluation of
the [psi][p] values
E.4.4 Calculation of a complete element
Annex F (informative) - Single assessment method:
Calculation example
F.1 General description of examples
F.2 Centre U-value of the glazing unit
F.3 Centre U-value of the spandrel panel
F.4 U-values of thermal joints
F.5 Overall U-value of the curtain wall
Specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.
DocumentType |
Standard
|
Pages |
57
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
Standards | Relationship |
I.S. EN 13947:2006 | Identical |
EN 13947:2006 | Identical |
UNI EN 13947 : 2007 | Identical |
NEN EN 13947 : 2007 | Identical |
NF EN 13947 : 2008 | Identical |
NS EN 13947 : 1ED 2006 | Identical |
NBN EN 13947 : 2007 | Identical |
SN EN 13947 : 2006 | Identical |
BS EN 13947:2006 | Identical |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
ISO 12567-1:2010 | Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors |
EN 12412-2:2003 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames |
EN 674:2011 | Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method |
EN 675:2011 | Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.