CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V

Available format(s)

Hardcopy

Language(s)

German

Published date

01-02-1994

€49.48
Excluding VAT

Vorwort
Anerkennungsnotiz
1 Allgemeines
2 Unterer Grenzwert des mittleren Aussendurchmessers
3 Oberer Grenzwert des mittleren Aussendurchmessers
4 Wanddicke der vorgeschriebenen Umhüllungen, ausser
  der Isolierung und dem Mantel (den Mänteln)
Anhang ZA (normativ) Andere in dieser Norm zitierte
          Internationale Normen mit den Verweisungen
          der entsprechenden Europäischen Normen

Specifies a method for the calculation of the lower and upper limits for the average outer diameter of cables and the outer dimensions of flat cords with circular copper conductors and of rated voltages up to and including 450/750 V. Does not apply to mineral insulated cables. Coverage includes: upper limit for the average outer diameter; lower limit for the average outer diameter; thickness of the mandatory coverings other than the insulation and the sheaths.

DocumentType
Standard
Pages
0
PublisherName
Verband Deutscher Elektrotechniker
Status
Current

Standards Relationship
NF EN 60719 : 1994 Identical
IEC 60719:1992 Identical
NBN EN 60719 : 1994 Identical
I.S. EN 60719:1994 Identical
SN EN 60719 : 1993 Identical
VDE 0299-2 : 1994 Identical
UNE-EN 60719:1994 Identical
BS EN 60719:1993 Identical
EN 60719:1993 Identical

DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
VDE 0281-12 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR
VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE

IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
DIN VDE 0299-1 : 1986 CALCULATION METHOD ON THE BASIS OF FICTITIOUS DIAMETERS FOR DETERMINATION OF DIMENSIONS OF PROTECTIVE COVERINGS FOR CABLES AND FLEXIBLE CORDS FOR POWER INSTALLATIONS - PART 1: POWER CABLES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.