• Shopping Cart
    There are no items in your cart

DIN ISO 16000-20:2015-11

Current

Current

The latest, up-to-date edition.

INDOOR AIR - PART 20: DETECTION AND ENUMERATION OF MOULDS - DETERMINATION OF TOTAL SPORE COUNT (ISO 16000-20:2014)

Available format(s)

Hardcopy , PDF

Language(s)

German, English

Published date

01-01-2015

€99.44
Excluding VAT

National foreword
National Annex NA (informative) - Bibliography
Introduction
1 Scope
2 Terms and definitions
3 Principle of method
4 Apparatus and materials
5 Reagents
6 Measurement procedure
7 Quality assurance
8 Calibration of flow rate, function control,
   and maintenance of the sampling system
9 Sampling protocol
10 Performance characteristics
Annex A (informative) - Examples of impactors
Annex B (normative) - Sample exchange for
        method validation
Bibliography

Defines requirements for sampling of moulds from air. Following the instructions given, samples are obtained for microscopy to determine the total concentration of spores.

DocumentType
Standard
Pages
21
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Current

Standards Relationship
ISO 16000-20:2014 Identical

DIN EN ISO 5492:2009-12 SENSORY ANALYSIS - VOCABULARY
VDI 4300 Blatt 1:1995-12 Indoor-air pollution measurement - General aspects of measurement strategy
DIN ISO 16362:2006-01 Ambient air - Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography (ISO 16362:2005)
VDI 4300 Blatt 5:2000-06 Indoor air pollution measurement - Measurement strategy for nitrogen dioxide (NO)
VDI 4301 Blatt 2:2000-06 Indoor air pollution measurement - Measurement of pentaclorphenol (PCP) and -hexachlorcyclohexane (lindane) - GC/MS-method
DIN EN ISO 16017-2:2003-09 INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 2: DIFFUSIVE SAMPLING
VDI 4300 Blatt 6:2000-12 Measurement of indoor air pollution - Measurement strategy for volatile organic compounds (VOCs)
VDI 4252 Blatt 2:2004-06 Measurement of airborne microorganisms and viruses in ambient air - Active sampling of bioaerosols - Separation of airborne mould on gelatine/polycarbonate filters
DIN ISO 12219-4:2013-12 INTERIOR AIR OF ROAD VEHICLES - PART 4: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - SMALL CHAMBER METHOD (ISO 12219-4:2013)
VDI 4300 Blatt 2:1997-12 Indoor-air pollution measurement - Measurement strategy for polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated bibhenyle (PCBs)
VDI 4301 Blatt 3:2003-06 Measurement of indoor air pollution - Measurement pentaclorophenol (PCP) and -hexachlorcyclohexane (lindane) - GC/ECD method
VDI 4300 Blatt 8:2001-06 Measurement of indoor air pollution - Sampling of house dust
VDI 3484 Blatt 2:2001-11 Gaseous ambient air measurements - Indoor-air pollution measurements - Measurement of the formaldehyde concentration with the acatylacetone method
ISO 4225:1994 Air quality General aspects Vocabulary
DIN ISO 12219-5:2014-10 INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014)
VDI 3498 Blatt 2:2002-07 Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using small filters
EN 13098:2000 Workplace atmosphere - Guidelines for measurement of airborne micro-organisms and endotoxin
VDI 3484 Blatt 1:2001-11 Gaseous ambient air measurements - Indoor-air pollution measurements - Test gases measurements; Measurement of the formaldehyde concentration with the sulfite pararosaniline method
VDI 4300 Blatt 9:2005-08 Measurement of indoor air pollution - Measurement strategy for carbon dioxide (CO)
DIN EN ISO 8589:2014-10 SENSORY ANALYSIS - GENERAL GUIDANCE FOR THE DESIGN OF TEST ROOMS (ISO 8589:2007 + AMD 1:2014)
VDI 4301 Blatt 6:2012-09 Measurement of indoor air pollution - Measurement of phthalates with GC/MS
VDI 2464 Blatt 3:2012-07 Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS
DIN ISO 12884:2000-12 Ambient air - Determination of total (gas and particle phase) polycyclic aromatic hydrocarbons - Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analysis (ISO 12884:2000)
VDI 4301 Blatt 4:2016-05 Measurement of indoor air pollution - Measurement of pyrethroids and piperonyl butoxide in air
ISO/TS 10832:2009 Soil quality — Effects of pollutants on mycorrhizal fungi — Spore germination test
VDI 4301 Blatt 1:1997-12 Indoor air pollution measurement - Determination of the concentration of nitrogen dioxide - Manual photometric method (Saltzman)
DIN ISO 12219-1:2013-12 Interior air of road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in cabin interiors (ISO 12219-1:2012)
VDI 4300 Blatt 10:2008-07 Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment
DIN ISO 12219-3:2013-12 Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012)
ISO 16000-19:2012 Indoor air — Part 19: Sampling strategy for moulds
DIN 50014:1985-07 CLIMATES AND THEIR TECHNICAL APPLICATION; STANDARD ATMOSPHERES
DIN EN ISO 16017-1:2001-10 INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 1: PUMPED SAMPLING
DIN ISO 12219-2:2012-11 Interior air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ISO 12219-2:2012)
VDI 4253 Blatt 2:2004-06 Measurement of airborne microorganisms and viruses in ambient air - Culture based method for the determination of the concentration of mould in air - Indirect method after sampling with gelatine/polycarbonate filters
VDI 4301 Blatt 5:2009-04 Measurement of indoor air pollution - Measurement of flame retardants and plasticizers based on organophosphorous compounds - Phosphoric acid ester
ISO 16000-16:2008 Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration
DIN EN ISO 8199:2008-01 Water quality - General guidance on the enumeration of micro-organisms by culture (ISO 8199:2005)
VDI 3498 Blatt 1:2002-07 Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using large filters

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.