DIN ISO 16000-20:2015-11
Current
The latest, up-to-date edition.
INDOOR AIR - PART 20: DETECTION AND ENUMERATION OF MOULDS - DETERMINATION OF TOTAL SPORE COUNT (ISO 16000-20:2014)
Hardcopy , PDF
German, English
01-01-2015
National foreword
National Annex NA (informative) - Bibliography
Introduction
1 Scope
2 Terms and definitions
3 Principle of method
4 Apparatus and materials
5 Reagents
6 Measurement procedure
7 Quality assurance
8 Calibration of flow rate, function control,
and maintenance of the sampling system
9 Sampling protocol
10 Performance characteristics
Annex A (informative) - Examples of impactors
Annex B (normative) - Sample exchange for
method validation
Bibliography
Defines requirements for sampling of moulds from air. Following the instructions given, samples are obtained for microscopy to determine the total concentration of spores.
| DocumentType |
Standard
|
| Pages |
21
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Current
|
| Standards | Relationship |
| ISO 16000-20:2014 | Identical |
| DIN EN ISO 5492:2009-12 | SENSORY ANALYSIS - VOCABULARY |
| VDI 4300 Blatt 1:1995-12 | Indoor-air pollution measurement - General aspects of measurement strategy |
| DIN ISO 16362:2006-01 | Ambient air - Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography (ISO 16362:2005) |
| VDI 4300 Blatt 5:2000-06 | Indoor air pollution measurement - Measurement strategy for nitrogen dioxide (NO) |
| VDI 4301 Blatt 2:2000-06 | Indoor air pollution measurement - Measurement of pentaclorphenol (PCP) and -hexachlorcyclohexane (lindane) - GC/MS-method |
| DIN EN ISO 16017-2:2003-09 | INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 2: DIFFUSIVE SAMPLING |
| VDI 4300 Blatt 6:2000-12 | Measurement of indoor air pollution - Measurement strategy for volatile organic compounds (VOCs) |
| VDI 4252 Blatt 2:2004-06 | Measurement of airborne microorganisms and viruses in ambient air - Active sampling of bioaerosols - Separation of airborne mould on gelatine/polycarbonate filters |
| DIN ISO 12219-4:2013-12 | INTERIOR AIR OF ROAD VEHICLES - PART 4: METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - SMALL CHAMBER METHOD (ISO 12219-4:2013) |
| VDI 4300 Blatt 2:1997-12 | Indoor-air pollution measurement - Measurement strategy for polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated bibhenyle (PCBs) |
| VDI 4301 Blatt 3:2003-06 | Measurement of indoor air pollution - Measurement pentaclorophenol (PCP) and -hexachlorcyclohexane (lindane) - GC/ECD method |
| VDI 4300 Blatt 8:2001-06 | Measurement of indoor air pollution - Sampling of house dust |
| VDI 3484 Blatt 2:2001-11 | Gaseous ambient air measurements - Indoor-air pollution measurements - Measurement of the formaldehyde concentration with the acatylacetone method |
| ISO 4225:1994 | Air quality — General aspects — Vocabulary |
| DIN ISO 12219-5:2014-10 | INTERIOR AIR OF ROAD VEHICLES - PART 5: SCREENING METHOD FOR THE DETERMINATION OF THE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS FROM VEHICLE INTERIOR PARTS AND MATERIALS - STATIC CHAMBER METHOD (ISO 12219-5:2014) |
| VDI 3498 Blatt 2:2002-07 | Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using small filters |
| EN 13098:2000 | Workplace atmosphere - Guidelines for measurement of airborne micro-organisms and endotoxin |
| VDI 3484 Blatt 1:2001-11 | Gaseous ambient air measurements - Indoor-air pollution measurements - Test gases measurements; Measurement of the formaldehyde concentration with the sulfite pararosaniline method |
| VDI 4300 Blatt 9:2005-08 | Measurement of indoor air pollution - Measurement strategy for carbon dioxide (CO) |
| DIN EN ISO 8589:2014-10 | SENSORY ANALYSIS - GENERAL GUIDANCE FOR THE DESIGN OF TEST ROOMS (ISO 8589:2007 + AMD 1:2014) |
| VDI 4301 Blatt 6:2012-09 | Measurement of indoor air pollution - Measurement of phthalates with GC/MS |
| VDI 2464 Blatt 3:2012-07 | Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS |
| DIN ISO 12884:2000-12 | Ambient air - Determination of total (gas and particle phase) polycyclic aromatic hydrocarbons - Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analysis (ISO 12884:2000) |
| VDI 4301 Blatt 4:2016-05 | Measurement of indoor air pollution - Measurement of pyrethroids and piperonyl butoxide in air |
| ISO/TS 10832:2009 | Soil quality — Effects of pollutants on mycorrhizal fungi — Spore germination test |
| VDI 4301 Blatt 1:1997-12 | Indoor air pollution measurement - Determination of the concentration of nitrogen dioxide - Manual photometric method (Saltzman) |
| DIN ISO 12219-1:2013-12 | Interior air of road vehicles - Part 1: Whole vehicle test chamber - Specification and method for the determination of volatile organic compounds in cabin interiors (ISO 12219-1:2012) |
| VDI 4300 Blatt 10:2008-07 | Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment |
| DIN ISO 12219-3:2013-12 | Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012) |
| ISO 16000-19:2012 | Indoor air — Part 19: Sampling strategy for moulds |
| DIN 50014:1985-07 | CLIMATES AND THEIR TECHNICAL APPLICATION; STANDARD ATMOSPHERES |
| DIN EN ISO 16017-1:2001-10 | INDOOR, AMBIENT AND WORKPLACE AIR - SAMPLING AND ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY SORBENT TUBE/THERMAL DESORPTION/CAPILLARY GAS CHROMATOGRAPHY - PART 1: PUMPED SAMPLING |
| DIN ISO 12219-2:2012-11 | Interior air of road vehicles - Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Bag method (ISO 12219-2:2012) |
| VDI 4253 Blatt 2:2004-06 | Measurement of airborne microorganisms and viruses in ambient air - Culture based method for the determination of the concentration of mould in air - Indirect method after sampling with gelatine/polycarbonate filters |
| VDI 4301 Blatt 5:2009-04 | Measurement of indoor air pollution - Measurement of flame retardants and plasticizers based on organophosphorous compounds - Phosphoric acid ester |
| ISO 16000-16:2008 | Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration |
| DIN EN ISO 8199:2008-01 | Water quality - General guidance on the enumeration of micro-organisms by culture (ISO 8199:2005) |
| VDI 3498 Blatt 1:2002-07 | Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using large filters |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.