• Shopping Cart
    There are no items in your cart

EN 1047-1:2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Secure storage units - Classification and methods of test for resistance to fire - Part 1: Data cabinets and diskette inserts

Superseded date

29-08-2019

Superseded by

EN 1047-1:2019

Published date

05-10-2005

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements, classification and locking
5 Test specimens, documents and correlation
  5.1 Test specimens
  5.2 Technical documentation of the test specimen
  5.3 Correlation of test specimen and technical
      documentation
6 Test methods
  6.1 Principle
  6.2 Test equipment
  6.3 Preparation for test
  6.4 Procedure
7 Expression of results
8 Test report
9 Marking
Annex A (informative) Examples of specimen preparation for the
                      fire shock and impact test
Annex B (informative) Example illustrating the requirements for
                      data inserts

This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts. Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum temperature increases and humidity values permitted within the storage space of the data cabinet.Diskette inserts (DI 60 P/DIS and DI 120 P/DIS) are installed in data cabinets of protection class S 60 P or S 120 P, respectively, and subjected to a fire endurance test (see 5.1.2).Requirements are also specified for test specimens, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures.A scheme to classify the fire resisting data cabinets and diskette inserts from the test results is also given (see Table 1).Cabinets having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, locking, etc.) will only give the same fire protection classification as that of a test specimen if they are of similar internal dimensions. The maximum difference in internal dimensions (height, width and depth of the storage space, measured from wall to wall) to which the test classification could apply is + 15 %. Cabinets having internal dimensions which differ by more than this amount from that of the tested specimen should be submitted to an extra test.The wall, ceiling and door thicknesses should not be below the specified minimum limit of the type-tested thickness by more than 3 %. ...

Committee
CEN/TC 263
DevelopmentNote
Supersedes UNE EN 1047-1. (08/2006)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy
Supersedes

I.S. EN 1047-2:2009 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
PREN 50600-2-5 : DRAFT 2012 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
17/30350914 DC : 0 BS EN 1047-2 - SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
UNI EN 1047-2 : 2013 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
09/30181168 DC : DRAFT JAN 2009 BS EN 1047-2 - SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
PREN 1047-2 : DRAFT 2017 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
PREN 15659 : DRAFT 2017 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - LIGHT FIRE STORAGE UNITS
12/30274114 DC : 0 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
11/30247940 DC : 0 BS EN 50600-2-1 - ELECTROTECHNICAL ASPECT OF TELECOMMUNICATION EQUIPMENT
BS EN 1047-2 : 2009 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
EN 1047-2:2009+A1:2013 Secure storage units - Classification and methods of test for resistance to fire - Part 2: Data rooms and data container
DIN EN 1047-2:2013-05 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
17/30350908 DC : 0 BS EN 15659 - SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - LIGHT FIRE STORAGE UNITS

EN 61515:2016 Mineral insulated metal-sheathed thermocouple cables and thermocouples
IEC 61515:2016 Mineral insulated metal-sheathed thermocouple cables and thermocouples
EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.