EN 1155:1997/A1:2002/AC:2006
Current
The latest, up-to-date edition.
BUILDING HARDWARE - ELECTRICALLY POWERED HOLD-OPEN DEVICES FOR SWING DOORS - REQUIREMENTS AND TEST METHODS
22-02-2006
Foreword
1 Scope
2 Normative references
3 Definitions
4 Classification
5 Requirements
6 Test apparatus
7 Test methods
8 Marking
9 Evaluation of conformity
Annex A (informative) Overload performance test apparatus
Annex B (normative) Flow chart of test procedures
Annex C (informative) Bibliography
Annex ZA (informative) Clauses addressing the provisions
of the EU Construction Products Directive (89/106/EEC)
Describes requirements for separate hold-open devices and also for hold-open mechanisms incorporated in a door closer intended to be used on fire/smoke compartmentation doors.
Committee |
CEN/TC 33
|
DocumentType |
Test Method
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 1155:2003 | Identical |
PN EN 1155 : 1999 AC 2006 | Identical |
NS EN 1155 : 1997 + A1 2002 | Identical |
BS EN 1155:1997 | Identical |
NEN EN 1155 : 1997 AMD 1/C1 2006 | Identical |
NBN EN 1155 : 1997 COR 2006 | Identical |
DIN EN 1155:2003-04 | Identical |
UNI EN 1155 : 2003 | Identical |
SN EN 1155 : 2003 | Identical |
NF EN 1155 : 97 AMD 1 2003 | Identical |
I.S. EN 1155:1998 | Identical |
DIN EN 1155:1997-10 | Identical |
BS EN 14846:2008 | Building hardware. Locks and latches. Electromechanically operated locks and striking plates. Requirements and test methods |
UNI EN 1634-2 : 2009 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
UNI EN 16034 : 2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
DIN EN 14846:2008-11 | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
UNI EN 14846 : 2008 | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
03/102595 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE |
UNE-EN 14846:2010 | Building hardware - Locks and latches - Electromechanically operated locks and striking plates - Requirements and test methods |
BS EN 1158:1997 | Building hardware. Door coordinator devices. Requirements and test methods |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
00/104442 DC : DRAFT JUNE 2000 | PREN 13916 - FIRE RESISTING DOORSETS - REQUIREMENTS AND CLASSIFICATION |
S.R. CEN TR 15894:2009 | BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS |
PREN 14846 : DRAFT 2015 | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
I.S. EN 1634-2:2008 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
I.S. EN 14846:2008 | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
DIN EN 14637 E : 2008 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE |
BS EN 1154:1997 | Building hardware. Controlled door closing devices. Requirements and test methods |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
UNI EN 1158 : 2003 | BUILDING HARDWARE - DOOR COORDINATOR DEVICES - REQUIREMENTS AND TEST METHODS |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
UNI EN 1154 : 2003 | BUILDING HARDWARE - CONTROLLED DOOR CLOSING DEVICES - REQUIREMENTS AND TEST METHODS |
07/30164493 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATIONS AND MAINTENANCE |
DIN EN 16034:2014-12 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
DIN EN 1634-2:2009-05 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
03/118296 DC : 0 | BS EN 14846 - BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
15/30298547 DC : 0 | BS EN 14846 - BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 14846:2008 | Building hardware - Locks and latches - Electromechanically operated locks and striking plates - Requirements and test methods |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 14637:2007 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 1634-2 : 2008 | Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware |
DIN EN 14846:2015-07 (Draft) | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
06/30154477 DC : 0 | EN 1634-2 - FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
PD CEN/TR 15894:2009 | Building hardware. Door fittings for use by children, elderly and disabled people in domestic and public buildings. A guide for specifiers |
DIN EN 14846 E : 2008 | BUILDING HARDWARE - LOCKS AND LATCHES - ELECTROMECHANICALLY OPERATED LOCKS AND STRIKING PLATES - REQUIREMENTS AND TEST METHODS |
09/30185830 DC : DRAFT FEB 2009 | BS EN 15887 - BUILDING HARDWARE - UNCONTROLLED DOOR CLOSING DEVICES FOR SINGLE ACTION DOORS - REQUIREMENTS AND TEST METHODS |
04/19991935 DC : DRAFT MAR 2004 | BS EN 1634-2 - FIRE RESISTANCE TESTS FOR DOOR AND SHUTTER ASSEMBLIES - PART 2: FIRE DOOR HARDWARE - BUILDING HARDWARE FOR FIRE RESISTING DOORSETS AND OPENABLE WINDOWS |
UNI CEN/TR 15894 : 2009 | BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS |
I.S. EN 1154:1997 | BUILDING HARDWARE - CONTROLLED DOOR CLOSING DEVICES - REQUIREMENTS AND TEST METHODS |
EN 1154:1996/A1:2002/AC:2006 | BUILDING HARDWARE - CONTROLLED DOOR CLOSING DEVICES - REQUIREMENTS AND TEST METHODS |
EN 1158:1997/A1:2002/AC:2006 | BUILDING HARDWARE - DOOR COORDINATOR DEVICES - REQUIREMENTS AND TEST METHODS |
CEN/TR 15894:2009 | Building hardware - Door fittings for use by children, elderly and disabled people in domestic and public buildings - A guide for specifiers |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
DIN EN 14637:2008-01 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
DIN 18263-5:1991-03 | DOOR CLOSER WITH HYDRAULIC CONTROL - DOOR CLOSERS WITH ELECTROMAGNETIC HOLD-OPEN DEVICES AND FREE-SWING DOOR CLOSERS |
EN 1670:2007/AC:2008 | BUILDING HARDWARE - CORROSION RESISTANCE - REQUIREMENTS AND TEST METHODS |
EN 1634-3:2004/AC:2006 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 3: SMOKE CONTROL TEST FOR DOOR AND SHUTTER ASSEMBLIES |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 1154:1996/A1:2002/AC:2006 | BUILDING HARDWARE - CONTROLLED DOOR CLOSING DEVICES - REQUIREMENTS AND TEST METHODS |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.