EN 1191:2012
Current
The latest, up-to-date edition.
Windows and doors - Resistance to repeated opening and closing - Test method
19-12-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4Test equipment
5 Test requirements
6 Preparation for testing
7 Test procedure
8 Test results
9 Test report
Annex A (normative) - Test procedures for Tilt and
Turn, Tilt-First, Turn-Only or Tilt-Only
windows and door-height windows
Annex B (normative) - Test procedures for Sliding, Lift
and Slide or Lift and Slide and Tilt windows
and door-height windows
Annex C (normative) - Test procedures for Tilt and Slide
windows and door-height windows
Annex D (normative) - Test procedures for Fold and Slide
windows and door-height windows
Annex E (normative) - Test procedures for horizontal or
vertical pivot windows and door-height windows
Annex F (normative) - Test procedures for Vertical Sliding
windows
Annex G (normative) - Test procedures for side-hung and
top-hung windows, opening outwards (including
reversible windows)
Annex H (normative) - Test procedures for side-hung
pedestrian doorsets excluding power operated doors
Annex I (normative) - Test procedures for power-operated
(automatic) side-hung single action pedestrian
doorsets
Bibliography
This European Standard specifies the method to be used to determine the resistance to repeated opening and closing of windows and pedestrian doorsets when subjected to repeated opening and closing. It applies to all construction materials and operating systems for any window or pedestrian doorset, including gaskets and building hardware, in normal operating conditions. The parts concerned in the testing are the frame, the opening component (including any additional moving components e.g. an inactive sash/leaf) and all essential and directly involved building hardware, including operating devices, for example, the handle.The testing does not include any hardware whose operation is not directly involved in the opening and closing of the moving components: added-on fastening systems such as peg-stays or cabin hooks or bolts, nor, unless specified, any independently installed stops (not connected to the complete assembly) such as a wall or ground-mounted stop.NOTE 1The Annexes provide more details on the testing procedures that may differ from the main part of this European Standard and are mandatory:-Annex A applies to Tilt and Turn, Tilt-First, Turn-Only, or Tilt-Only windows and door-height windows;-Annex B applies to Sliding, Lift and Slide or Lift and Slide and Tilt windows and door-height windows;-Annex C applies to Tilt and Slide windows and door-height windows;-Annex D applies to Fold and Slide windows and door-height windows;-Annex E applies to horizontal and vertical pivot windows and door-height windows;-Annex F applies to Vertical Sliding windows;-Annex G applies to side-hung casements and top-hung windows, opening outwards (including reversible windows);-Annex H applies to side-hung single swing pedestrian doorsets excluding power operated doors;-Annex I applies to power-operated (automatic) side-hung single-swing pedestrian doorsets.NOTE 2In this European Standard the term door-height window is used for windows that are used for the passage of pedestrians, i.e. as a pedestrian doorset.
Committee |
CEN/TC 33
|
DevelopmentNote |
Supersedes PREN 1191. (01/2013)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN EN 1191 : 2012 | Identical |
NF EN 1191 : 2013 | Identical |
UNE-EN 1191:2013 | Identical |
DIN EN 1191:2013-04 | Identical |
SN EN 1191 : 2012 | Identical |
UNI EN 1191 : 2013 | Identical |
BS EN 1191:2012 | Identical |
PN EN 1191 : 2013 | Identical |
NS EN 1191 : 2012 | Identical |
I.S. EN 1191:2012 | Identical |
NBN EN 1191 : 2013 | Identical |
I.S. EN 13126-16:2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 16: HARDWARE FOR LIFT&SLIDE WINDOWS AND DOORS |
UNE-EN 13126-5:2012 | Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows |
PREN 13126-15 : DRAFT 2017 | QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
16/30340523 DC : 0 | BS EN 17020-4 - EXTENDED APPLICATION OF TEST RESULTS ON DURABILITY OF SELFCLOSING FOR DOORSETS AND OPENABLE WINDOWS - PART 4: DURABILITY OF SELF-CLOSING OF FIRE RESISTANCE HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
BS EN 16580:2015 | Windows and doors. Wetness and splash water proof door leaves. Test and classification |
PREN 13126-8 : DRAFT 2016 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
17/30335089 DC : 0 | BS EN 13126-6 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY) |
PREN 13126-6 : DRAFT 2017 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY) |
UNE-EN 16580:2016 | Windows and doors - Wetness and splash water proof door leaves - Test and classification |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
18/30361306 DC : 0 | BS EN 13126-16 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS |
UNI EN 16034 : 2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
BS EN 13126-17:2008 | Building hardware. Requirements and test methods for windows and doors height windows Hardware for Tilt&Slide windows and doors |
BS EN 13126-8:2017 | Building hardware. Hardware for windows and door height windows Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware |
UNI EN 13126-16 : 2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 16: HARDWARE FOR LIFT & SLIDE WINDOWS AND DOORS |
BS EN 12400:2002 | Windows and pedestrian doors. Mechanical durability. Requirements and classification |
DIN EN 13126-16:2008-04 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 16: HARDWARE FOR LIFT&SLIDE WINDOWS AND DOORS |
EN 13126-5:2011+A1:2014 | Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows |
EN 12400:2002 | Windows and pedestrian doors - Mechanical durability - Requirements and classification |
EN 1366-7:2004 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
I.S. EN 16580:2015 | WINDOWS AND DOORS - WETNESS AND SPLASH WATER PROOF DOOR LEAVES - TEST AND CLASSIFICATION |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
UNI EN 13126-5 : 2014 | A BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 5: DEVICES THAT RESTRICT THE OPENING OF WINDOWS AND DOOR HEIGHT WINDOWS |
DIN EN 16035:2013-03 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the interchangeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
I.S. EN 16035:2012 | HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTER-CHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND/OR SMOKE CONTROL DOORSETS AND/OR OPENABLE WINDOWS |
UNI EN 13126-15 : 2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND SLIDING FOLDING WINDOWS AND DOORS |
BS EN 13126-15:2008 | Building hardware. Requirements and test methods for windows and doors height windows Rollers for horizontal sliding and sliding folding windows and doors |
EN 13126-16:2008 | Building hardware - Requirements and test methods for windows and doors height windows - Part 16: Hardware for Lift&Slide windows and doors |
PREN 13126-17 : DRAFT 2018 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
07/30164493 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATIONS AND MAINTENANCE |
PREN 1125 : DRAFT 2016 | BUILD HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
10/30211853 DC : 0 | BS EN 16035 - HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTERCHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND SMOKE CONTROL DOORSETS AND OPENABLE WINDOWS |
BS EN 16035:2012 | Hardware performance sheet (HPS). Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
DIN EN 16580:2015-10 | Windows and doors - Wetness and splash water proof door leaves - Test and classification |
00/104442 DC : DRAFT JUNE 2000 | PREN 13916 - FIRE RESISTING DOORSETS - REQUIREMENTS AND CLASSIFICATION |
I.S. EN 13126-8:2017 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT AND TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
I.S. EN 13126-15:2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND SLIDING FOLDING WINDOWS AND DOORS |
EN 13126-15:2008 | Building hardware - Requirements and test methods for windows and doors height windows - Part 15: Rollers for horizontal sliding and sliding folding windows and doors |
PREN 179 : DRAFT 2016 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNI EN 16035 : 2013 | HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTER-CHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND/OR SMOKE CONTROL DOORSETS AND/OR OPENABLE WINDOWS |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
PREN 13126-16 : DRAFT 2018 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS |
EN 13126-17:2008 | Building hardware - Requirements and test methods for windows and doors height windows - Part 17: Hardware for Tilt&Slide windows and doors |
18/30361302 DC : 0 | BS EN 13126-17 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS |
UNI EN 13126-17 : 2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 17: HARDWARE FOR TILT & SLIDE WINDOWS AND DOORS |
DIN EN 1366-7:2004-09 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
16/30335086 DC : 0 | BS EN 13126-8 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE |
DIN EN 16034:2014-12 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
EN 13126-8:2017 | Building hardware - Hardware for windows and door height windows - Part 8: Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 14637:2007 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
EN 16580:2015 | Windows and doors - Wetness and splash water proof door leaves - Test and classification |
EN 16035:2012 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
14/30294044 DC : 0 | BS EN 13126-5:2011/A1 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 5: DEVICES THAT RESTRICT THE OPENING OF WINDOWS AND DOOR HEIGHT WINDOWS |
DIN EN 13126-5:2015-01 | Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows and door height windows; German version EN 13126-5:2011+A1:2014 |
BS EN 13126-5 : 2011 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 5: DEVICES THAT RESTRICT THE OPENING OF WINDOWS AND DOOR HEIGHT WINDOWS |
I.S. EN 13126-5:2011 | BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 5: DEVICES THAT RESTRICT THE OPENING OF WINDOWS AND DOOR HEIGHT WINDOWS |
I.S. EN 13126-17:2008 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 17: HARDWARE FOR TILT&SLIDE WINDOWS AND DOORS |
BS EN 13126-16:2008 | Building hardware. Requirements and test methods for windows and doors height windows Hardware for Lift&Slide windows and doors |
18/30361299 DC : 0 | BS EN 13126-15 - QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS |
16/30343249 DC : 0 | BS EN 179 - BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
16/30343246 DC : 0 | BS EN 1125 - BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
BS EN 1366-7:2004 | Fire resistance tests for service installations Conveyor systems and their closures |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
DIN EN 13126-17:2008-04 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 17: HARDWARE FOR TILT&SLIDE WINDOWS AND DOORS |
DIN EN 13126-15:2008-04 | BUILDING HARDWARE - REQUIREMENTS AND TEST METHODS FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND SLIDING FOLDING WINDOWS AND DOORS |
DIN EN 14637:2008-01 | Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
PREN 16361 : DRAFT 2011 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS |
EN 12400:2002 | Windows and pedestrian doors - Mechanical durability - Requirements and classification |
EN 13115:2001 | Windows - Classification of mechanical properties - Racking, torsion and operating forces |
PREN 16034 : DRAFT 2009 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
EN 12519:2004 | Windows and pedestrian doors - Terminology |
EN 12046-2:2000 | Operating forces - Test method - Part 2: Doors |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN 12217:2015 | Doors - Operating forces - Requirements and classification |
EN 12046-1:2003 | Operating forces - Test method - Part 1: Windows |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.