EN 12086:2013
Current
The latest, up-to-date edition.
Thermal insulating products for building applications - Determination of water vapour transmission properties
13-03-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Test specimens
7 Procedure
8 Calculation and expression of results
9 Accuracy of measurement
10 Test report
Annex A (informative) - Conversion table for water
vapour transmission units
Annex B (informative) - Examples of test assemblies
Annex C (informative) - Information about correction
procedures
Bibliography
This European Standard specifies the equipment and procedures for determining the water vapour transmission rate, water vapour permeance and water vapour permeability of test specimens in the steady state under different sets of specified test conditions. It is applicable to thermal insulating products.It is intended to be used for homogeneous materials and for products which may contain integral skins or facings of different material(s).A material is considered to be homogeneous, with regard to mass distribution, if its density is approximately the same throughout, i.e. if the measured density values are close to its mean density.This test method is not normally used for determining the water vapour transmission properties of single, separate vapour barriers (of high diffusion resistance), such as prefabricated films, foils, membranes or sheets, due to the long duration of the test. For products with a vapour retarder or barrier with a water vapour diffusion equivalent air layer thickness sd 1 000 m (see 3.6) other test methods e.g. IR-detection can be used for measuring the single separate vapour retarder or barrier, provided that the results obtained are in the same range as the values measured in accordance with this standard.The water vapour transmission rate and permeance values are specific to the test specimen (i.e. the product) thickness tested. For homogeneous products, the water vapour permeability is a property of the material.
Committee |
CEN/TC 88
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NBN EN 12086 : 2013 | Identical |
NS EN 12086 : 2013 | Identical |
UNE-EN 12086:2013 | Identical |
GOST R EN 12086 : 2008 | Identical |
PN EN 12086 : 2013 | Identical |
BS EN 12086:2013 | Identical |
NF EN 12086 : 2013 | Identical |
NEN EN 12086 : 2013 | Identical |
I.S. EN 12086:2013 | Identical |
SN EN 12086 : 2013 | Identical |
DIN EN 12086:2013-06 | Identical |
UNI EN 12086 : 2013 | Identical |
I.S. EN 14314:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
15/30315069 DC : DRAFT MAY 2015 | BS EN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
09/30203742 DC : 0 | BS ISO 12629 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF WATER VAPOUR TRANSMISSION PROPERTIES OF PREFORMED PIPE INSULATION |
09/30207822 DC : 0 | BS EN 15600-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 14313 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
02/120707 DC : 0 | PREN 14320-1 - THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE FOAM (PUR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
02/120709 DC : 0 | PREN 14319-1 - THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE FOAM (PUR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
UNE-EN 14306:2017 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
DIN EN 15600-1:2010-12 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation |
15/30315078 DC : DRAFT MAY 2015 | BS EN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
10/30213965 DC : 0 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
12/30256784 DC : 0 | BS EN 13469 - THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF WATER VAPOUR TRANSMISSION PROPERTIES OF PREFORMED PIPE INSULATION |
05/30136503 DC : 0 | PREN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
PD CEN/TS 16354:2013 | Laminate floor coverings. Underlays. Specification, requirements and test methods |
05/30134359 DC : DRAFT MAY 2005 | EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL CELLULOSE PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
PREN 14309 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
02/120714 DC : 0 | PREN 14318-1 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE FOAM (PUR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID POLYURETHANE DISPENSE SYSTEM BEFORE INSTALLATION |
DIN EN 14306:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
02/101684 DC : DRAFT FEB 2002 | PREN 14316-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 16069:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
PREN 13169 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 14304:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
I.S. EN 15101-1:2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
I.S. EN 16069:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
15/30301583 DC : 0 | BS EN 16863 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE REFLECTIVE INSULATION PRODUCTS (RI) - SPECIFICATION |
UNI EN 15101-1 : 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
UNE-EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 15101-1:2013 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
PREN 16809-1 : DRAFT 2014 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED PRODUCTS FROM LOOSE-FILL EXPANDED POLYSTYRENE (EPS) BEADS AND BONDED EXPANDED POLYSTYRENE BEADS - PART 1: SPECIFICATION FOR THE BONDED AND LOOSE FILLED PRODUCTS BEFORE INSTALLATION |
DIN EN 13169:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 13469:2013-01 | Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation |
BS EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0°C and -165°C Insulation components |
BS EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of expanded polystyrene (EPS). Specification |
BS EN 13168 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS EN 13403:2003 | Ventilation for buildings. Non metallic ducts. Ductwork made from insulation ductboards |
BS EN 13164 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 13168:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
I.S. EN 13469:2012 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF WATER VAPOUR TRANSMISSION PROPERTIES OF PREFORMED PIPE INSULATION |
I.S. EN 13165:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
CEN/TS 16354:2013 | Laminate floor coverings - Underlays - Specification, requirements and test methods |
DIN EN 13813:2003-01 | SCREED MATERIAL AND FLOOR SCREEDS - SCREED MATERIALS - PROPERTIES AND REQUIREMENTS |
DIN EN 14933:2007-12 | Thermal insulation and light weigth fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
EN 13469:2012 | Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation |
EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 13163:2012+A2:2016 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
15/30315087 DC : DRAFT MAY 2015 | BS EN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam dispensed system before installation |
I.S. EN 14320-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
08/30169546 DC : DRAFT APR 2008 | BS EN 13167 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 16025-1:2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
15/30315075 DC : DRAFT MAY 2015 | BS EN 14305 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 15501:2013 | Thermal insulation products for building equipment and industrial installations. Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products. Specification |
I.S. EN 14315-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
05/30136538 DC : 0 | PREN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 14307:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
15/30315081 DC : DRAFT MAY 2015 | BS EN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
BS EN 15600-1:2010 | Thermal insulation products for building equipment and industrial installations. In-situ thermal insulation formed from exfoliated vermiculite (EV) products Specification for bonded and loose-fill products before installation |
10/30213980 DC : 0 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 16025-1:2013-07 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
05/30136516 DC : 0 | PREN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
10/30213986 DC : 0 | BS EN 13171 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
BS EN 16025-1:2013 | Thermal and/or sound insulating products in building construction. Bound EPS ballastings Requirements for factory premixed EPS dry plaster |
08/30169559 DC : DRAFT APR 2008 | BS EN 13171 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
PREN 13165 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
PREN 15501 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
10/30213971 DC : 0 | BS EN 13166 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 14303 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 15600-1 : DRAFT 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 13164 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
08/30169552 DC : DRAFT APR 2008 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED PERLITE (EPB) - SPECIFICATION |
PREN 13454-1 : DRAFT 2017 | BINDERS AND FACTORY MADE MIXTURES FOR FLOOR SCREEDS BASED ON CALCIUM SULPHATE - PART 1: DEFINITIONS AND REQUIREMENTS |
I.S. EN 14305:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
PREN 14314 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
05/30136550 DC : 0 | PREN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
PREN 14304 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
DIN EN 14313:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
I.S. EN 14309:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
PREN 13813 : DRAFT 2017 | SCREED MATERIAL AND FLOOR SCREEDS - SCREED MATERIAL - PROPERTIES AND REQUIREMENTS |
DIN EN 14308:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
UNE-EN 14309:2017 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
DIN EN 14309:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
PREN 14305 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 14304 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
I.S. EN 15600-1:2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 14306 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
DIN EN 15101-1:2013-12 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
12/30268937 DC : 0 | BS EN 16491 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
PREN 14933 : DRAFT 2004 | LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
DIN EN 13170:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
DIN EN 13164:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 13165:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
DIN EN 13166:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
DIN EN 13168:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
DIN EN 13162:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
BS EN 13169 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 13163:2017-02 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13164:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 13163:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13166:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
I.S. EN 13167:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 13171:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
I.S. EN 13170:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
I.S. EN 13169:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
I.S. EN 13162:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
02/701820 DC : 0 | BS EN 14303 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
BS EN 14314:2015 | Thermal insulation products for building equipment and industrial installations. Factory made phenolic foam (PF) products. Specification |
BS EN 15599-1:2010 | Thermal insulation products for building equipment and industrial installations. In-situ thermal insulation formed from expanded perlite (EP) products Specification for bonded and loose-fill products before installation |
DIN EN 14320-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
01/103304 DC : DRAFT APR 2001 | PREN 14190 - GYPSUM PLASTERBOARD PRODUCTS FROM SECONDARY PROCESSING - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
13/30258117 DC : 0 | BS EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
DIN EN 15599-1:2010-12 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation |
BS EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation |
BS EN 16069 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
PREN 13167 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
UNI EN 15599-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNI EN 14320-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
I.S. EN 14319-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
BS ISO 2219:2010 | Thermal insulation products for buildings. Factory-made products of expanded cork (ICB). Specification |
UNE-EN 14305:2017 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
12/30270374 DC : 0 | BS EN 15501 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
15/30315072 DC : DRAFT MAY 2015 | BS EN 14306 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
08/30169549 DC : DRAFT APR 2008 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
10/30213977 DC : 0 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
DIN EN 14315-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
02/120711 DC : 0 | PREN 14315-1 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE FOAM (PUR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
04/30126133 DC : DRAFT NOV 2004 | EN 15100-1 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED UREAFORMALDEHYDE FOAM (UF) PRODUCTS - PART 1: SPECIFICATION FOR THE FOAM SYSTEM BEFORE INSTALLATION |
04/30113509 DC : DRAFT MAY 2004 | BS EN 14934 - THERMAL INSULATION OF ROAD AND RAILWAYS AND EMBANKMENT FILLING - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
UNI CEN/TS 16354 : 2014 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
10/30213974 DC : 0 | BS EN 13167 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
UNE-EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 14313:2017 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
PREN 13162 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 14308 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
DIN EN 14303:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
DIN EN 15501:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
I.S. EN 15599-1:2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 16354 : DRAFT 2016 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
I.S. EN 14306:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
I.S. EN 14313:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
ISO 2219:2010 | Thermal insulation products for buildings — Factory-made products of expanded cork (ICB) — Specification |
PREN 15599-1 : DRAFT 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNI EN 16025-1 : 2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
UNI EN 14319-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 14307 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
PREN 13171 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
DIN EN 13171:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
DIN EN 13167:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
DIN EN 13454-1:2005-01 | Binders, composite binders and factory made mixtures for floor screeds based on calcium sulfate - Part 1: Definitions and requirements; German version EN 13454-1:2004 |
DIN EN 13163:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
BS EN 12089:2013 | Thermal insulating products for building applications. Determination of bending behaviour |
UNE-EN 13469:2015 | Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation |
UNI EN 13469 : 2012 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF WATER VAPOUR TRANSMISSION PROPERTIES OF PREFORMED PIPE INSULATION |
UNI EN 13403 : 2004 | VENTILATION FOR BUILDINGS - NON- METALLIC DUCTS - DUCTWORK MADE FROM INSULATION DUCTBOARDS |
00/105211 DC : DRAFT JULY 2000 | PREN 13950 - GYPSUM PLASTERBOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
10/30213983 DC : 0 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
17/30354084 DC : 0 | BS EN 16855-2 - WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 2: CUSTOMIZED COLD ROOMS |
16/30330679 DC : DRAFT MAR 2016 | BS EN 16977 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
08/30169540 DC : DRAFT APR 2008 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) PRODUCTS - SPECIFICATION |
15/30315090 DC : DRAFT MAY 2015 | BS EN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
PREN 13170 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
05/30136552 DC : 0 | PREN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) - SPECIFICATION |
PREN 14303 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
UNI EN 14315-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNI EN 14318-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 13168 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS EN 14308:2015 | Thermal insulation products for building equipment and industrial installations. Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products. Specification |
BS EN 14306:2015 | Thermal insulation products for building equipment and industrial installations. Factory made calcium silicate (CS) products. Specification |
08/30169543 DC : DRAFT APR 2008 | BS EN 13166 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF PHENOLIC FOAM (PF) - SPECIFICATION |
00/107014 DC : DRAFT OCT 2000 | PREN 520 - GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
08/30169534 DC : DRAFT APR 2008 | BS EN 13163 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
UNE-EN 14307:2017 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
00/106800 DC : DRAFT OCT 2000 | PREN 13915 - PREFABRICATED GYPSUM WALLBOARD PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
10/30213959 DC : 0 | BS EN 13162 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
08/30169531 DC : DRAFT APR 2008 | BS EN 13162 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
15/30315084 DC : DRAFT MAY 2015 | BS EN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
03/105151 DC : DRAFT MAR 2003 | PREN 14620-4 - DESIGN AND MANUFACTURE OF SITE BUILT, VERTICAL, CYLINDRICAL, FLAT-BOTTOMED STEEL TANKS FOR THE STORAGE OF REFRIGERATED, LIQUEFIED GASES WITH OPERATING TEMPERATURES BETWEEN -5 DEGREES C AND -165 DEGREES C - PART 4: INSULATION COMPONENTS |
15/30315096 DC : DRAFT MAY 2015 | BS EN 15501 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
BS EN 14305:2015 | Thermal insulation products for building equipment and industrial installations. Factory made cellular glass (CG) products. Specification |
NF EN 15600-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNE-EN 14308:2017 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
NF EN 15599-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 14314:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
PREN 15101-1 : DRAFT 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 14309:2015 | Thermal insulation products for building equipment and industrial installations. Factory made products of expanded polystyrene (EPS). Specification |
17/30357436 DC : 0 | BS EN 13454-1 - BINDERS AND FACTORY MADE MIXTURES FOR FLOOR SCREEDS BASED ON CALCIUM SULPHATE - PART 1: DEFINITIONS AND REQUIREMENTS |
PREN 16491 : DRAFT 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
ISO 12629:2011 | Thermal insulating products for building equipment and industrial installations — Determination of water vapour transmission properties of preformed pipe insulation |
I.S. EN 14308:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
DIN EN 13403:2003-08 | VENTILATION FOR BUILDINGS - NON-METALLIC DUCTS - DUCTWORK MADE FROM INSULATION DUCTBOARDS |
BS EN 13167 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 13171 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
BS EN 13165 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
UNE-EN 13166:2013 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
UNE-EN 13167:2013 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
UNE-EN 13164:2013 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
BS EN 13166 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
UNE-EN 13169:2013 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
BS EN 13162 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
BS EN 13813:2002 | Screed material and floor screeds. Screed material. Properties and requirements |
UNE-EN 13162:2013 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
UNE-EN 13165:2013 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
UNE-EN 13171:2013 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
BS EN 13454-1:2004 | Binders, composite binders and factory made mixtures for floor screeds based on calcium sulfate Definitions and requirements |
UNE-EN 13163:2013 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
UNE-EN 16069:2013 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
UNE-EN 13170:2013 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
UNE-EN 13168:2013 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
UNE-EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
EN 14308:2015 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
EN 14306:2015 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 14305:2015 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
EN 13168:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
EN 14307:2015 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 13164:2012+A1:2015 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 16069:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
EN 14309:2015 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
EN 13171:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
EN 14304:2015 | Thermal insulation products for building equipment and industrial installations - Factory made flexible elastomeric foam (FEF) products - Specification |
EN 15600-1:2010 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
EN 15599-1:2010 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
EN 14314:2015 | Thermal insulation products for building equipment and industrial installations - Factory made phenolic foam (PF) products - Specification |
EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
EN 15501:2015 | Thermal insulation products for building equipment and industrial installations - Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products - Specification |
EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 14313:2015 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 4: Insulation components |
EN 14303:2015 | Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification |
EN 13813:2002 | Screed material and floor screeds - Screed material - Properties and requirements |
EN 16025-1:2013 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
08/30169537 DC : DRAFT APR 2008 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
DIN EN 14318-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 13469 : DRAFT 2012 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF WATER VAPOUR TRANSMISSION PROPERTIES OF PREFORMED PIPE INSULATION |
BS EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam spray system before installation |
I.S. EN 15501:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
08/30194543 DC : 0 | BS ISO 2219 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY-MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
10/30213968 DC : 0 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
DIN EN 14319-1:2013-04 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
09/30207815 DC : 0 | BS EN 15599-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
BS EN 14318-1:2013 | Thermal insulating products for buildings. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam dispensed system before installation |
08/30169556 DC : DRAFT APR 2008 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
UNE-EN 16025-1:2016 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
UNE-EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
15/30315093 DC : DRAFT MAY 2015 | BS EN 14303 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
05/30136556 DC : 0 | PREN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATION - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
10/30213989 DC : 0 | BS EN 16069 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
09/30209668 DC : 0 | BS EN 16025-1 - THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
04/30113504 DC : DRAFT MAY 2004 | BS EN 14933 - LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
02/101686 DC : DRAFT FEB 2002 | PREN 14317-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNE-EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane foam (PUR) products. Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 15501:2017 | Thermal insulation products for building equipment and industrial installations - Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products - Specification |
PREN 13166 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
I.S. EN 14304:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
ISO 16544:2012 | Thermal insulating products for building applications — Conditioning to moisture equilibrium under specified temperature and humidity conditions |
BS EN 14307:2015 | Thermal insulation products for building equipment and industrial installations. Factory made extruded polystyrene foam (XPS) products. Specification |
DIN EN 14305:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
16/30333219 DC : 0 | BS EN 16354 - LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
UNE-EN 15101-1:2015 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
BS EN 15101-1:2013 | Thermal insulation products for buildings. In-situ formed loose fill cellulose (LFCI) products Specification for the products before installation |
I.S. EN 14318-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
S.R. CEN/TS 16354:2013 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
I.S. EN 14303:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
UNI EN 15600-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
BS EN 14313 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
I.S. EN 14307:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
BS EN 13163 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
BS EN 13469:2012 | Thermal insulating products for building equipment and industrial installations. Determination of water vapour transmission properties of preformed pipe insulation |
BS EN 13170 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
BS EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of extruded polystyrene foam (XPS). Specification |
EN 13403:2003 | Ventilation for buildings - Non-metallic ducts - Ductwork made from insulation ductboards |
EN 13454-1:2004 | Binders, composite binders and factory made mixtures for floor screeds based on calcium sulfate - Part 1: Definitions and requirements |
EN 13170:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
EN 13169:2012+A1:2015 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
EN 13167:2012+A1:2015 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
DIN EN 14934:2007-12 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
EN 13165:2012+A2:2016 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
UNE-EN 13162:2013+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 12085:2013 | Thermal insulating products for building applications - Determination of linear dimensions of test specimens |
ISO 9346:2007 | Hygrothermal performance of buildings and building materials — Physical quantities for mass transfer — Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.