EN 1287:2017
Current
The latest, up-to-date edition.
Sanitary tapware - Low pressure thermostatic mixing valves - General technical specification
16-08-2017
European Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and units
5 Classification
6 Designation
7 Marking/identification
8 Materials
9 Dimensional characteristics
10 Backflow protection
11 Test sequence
12 Leaktightness
13 Performance
14 Pressure resistance
15 Torsional resistance of the operating controls
16 Mechanical endurance characteristics
Annex A (normative) - Test set-up descriptions
Annex B (normative) - Measurements
Annex C (informative) - Temperature transit
Annex D (normative) - Hydraulic resistance for low
pressure diverters with automatic return
Bibliography
This European Standard specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature needs to be set at a suitable bathing temperature (body temperature - 38 °C) as children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children during bathing.It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.This standard allows TMVs to supply a single outlet or a small number of outlets in a "domestic" application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.Table 1 - Conditions of use
Committee |
CEN/TC 164
|
DevelopmentNote |
Supersedes PREN 1287. (08/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PN EN 1287 : 2017 | Identical |
UNE-EN 1287:2000 | Identical |
I.S. EN 1287:2017 | Identical |
NF EN 1287 : 2017 | Identical |
DIN EN 1287:2015-07 (Draft) | Identical |
NBN EN 1287 : 1999 | Identical |
SN EN 1287 : 2017 | Identical |
NS EN 1287 : 2017 | Identical |
UNI EN 1287 : 2002 | Identical |
NEN EN 1287 : 2017 | Identical |
BS EN 1287:2017 | Identical |
UNE-EN 1287:2018 | Identical |
UNI EN 1287:2017 | Identical |
DIN EN 1287:2017-10 | Identical |
BS EN 16146 : 2012 | SANITARY TAPWARE - EXTRACTABLE SHOWER HOSES FOR SANITARY TAPWARE FOR SUPPLY SYSTEMS TYPE 1 AND TYPE 2 - GENERAL TECHNICAL SPECIFICATION |
DIN EN 15200:2007-08 | Sanitary appliances - Multifunction shower cabinets |
EN 1111:2017 | Sanitary tapware - Thermostatic mixing valves (PN 10) - General technical specification |
DIN EN 1111:2017-10 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
13/30280712 DC : 0 | BS EN 1111 - SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
BS EN 14506:2005 | Devices to prevent pollution by backflow of potable water. Automatic diverter. Family H, type C |
DIN EN 16145:2013-03 | Sanitary tapware - Extractable outlets for sink and basin mixers - General technical specification |
I.S. EN 14506:2005 | DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - AUTOMATIC DIVERTER - FAMILY H, TYPE C |
I.S. EN 16145:2012 | SANITARY TAPWARE - EXTRACTABLE OUTLETS FOR SINK AND BASIN MIXERS - GENERAL TECHNICAL SPECIFICATION |
UNI EN 16145 : 2013 | SANITARY TAPWARE - EXTRACTABLE OUTLETS FOR SINK AND BASIN MIXERS - GENERAL TECHNICAL SPECIFICATION |
I.S. EN 1111:2017 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
10/30228910 DC : 0 | BS EN 16146 - SANITARY TAPWARE - EXTRACTABLE SHOWER HOSES FOR SANITARY TAPWARE FOR SUPPLY SYSTEMS TYPE 1 AND TYPE 2 - GENERAL TECHNICAL SPECIFICATION |
10/30228907 DC : 0 | BS EN 16145 - SANITARY TAPWARE - EXTRACTABLE OUTLETS FOR SINK AND BASIN MIXERS - GENERAL TECHNICAL SPECIFICATION |
15/30321802 DC : 0 | BS EN 1111 - SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
S.R. CEN/TR 16355:2012 | RECOMMENDATIONS FOR PREVENTION OF LEGIONELLA GROWTH IN INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION |
UNI EN 15200 : 2007 | SANITARY APPLIANCES - MULTIFUNCTION SHOWER CABINETS |
BS EN 16145:2012 | Sanitary tapware. Extractable outlets for sink and basin mixers. General technical specification |
DIN EN 16146:2015-02 | Sanitary tapware - Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2 - General technical specification; German version EN 16146:2012+A1:2014 |
UNI CEN/TR 16355 : 2012 | RECOMMENDATIONS FOR PREVENTION OF LEGIONELLA GROWTH IN INSTALLATIONS INSIDE BUILDINGS CONVEYING WATER FOR HUMAN CONSUMPTION |
I.S. EN 16146:2012 | SANITARY TAPWARE - EXTRACTABLE SHOWER HOSES FOR SANITARY TAPWARE FOR SUPPLY SYSTEMS TYPE 1 AND TYPE 2 - GENERAL TECHNICAL SPECIFICATION |
BS EN 1111:2017 | Sanitary tapware. Thermostatic mixing valves (PN 10). General technical specification |
BS EN 15200:2007 | Sanitary appliances. Multifunction shower cabinets |
EN 14506:2005 | Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H, type C |
EN 16146:2012+A1:2014 | Sanitary tapware - Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2 - General technical specification |
13/30280715 DC : 0 | BS EN 1287 - SANITARY TAPWARE - LOW PRESSURE THERMOSTATIC MIXING VALVES - GENERAL TECHNICAL SPECIFICATIONS |
PREN 1111 : DRAFT 2015 | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
UNE-EN 16145:2014 | Sanitary tapware - Extractable outlets for sink and basin mixers - General technical specification |
UNI EN 16146 : 2014 | SANITARY TAPWARE - EXTRACTABLE SHOWER HOSES FOR SANITARY TAPWARE FOR SUPPLY SYSTEMS TYPE 1 AND TYPE 2 - GENERAL TECHNICAL SPECIFICATION |
DIN EN 1111:2015-07 (Draft) | SANITARY TAPWARE - THERMOSTATIC MIXING VALVES (PN 10) - GENERAL TECHNICAL SPECIFICATION |
CEN/TR 16355:2012 | Recommendations for prevention of Legionella growth in installations inside buildings conveying water for human consumption |
DIN EN 14506:2005-08 | Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H, type C |
UNE-EN 1111:2018 | Sanitary Tapware - Thermostatic Mixing Valves (PN 10) - General Technical Specification |
UNE-EN 16146:2013 | Sanitary tapware - Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2 - General technical specification |
PD 6504:1983 | Medical information on human reaction to skin contact with hot surfaces |
EN 246:2003 | Sanitary tapware - General specifications for flow rate regulators |
EN 1112:2008 | Sanitary tapware - Shower outlets for sanitary tapware for water supply systems of type 1 and type 2 - General technical specification |
EN 1057:2006+A1:2010 | Copper and copper alloys - Seamless, round copper tubes for water and gas in sanitary and heating applications |
ISO 13732-1:2006 | Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces |
EN 13618:2016 | Flexible hose assemblies in drinking water installations - Functional requirements and test methods |
EN 1113:2015 | Sanitary tapware - Shower hoses for sanitary tapware for water supply systems of type 1 and type 2 - General technical specification |
EN 1717:2000 | Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow |
EN ISO 13732-1:2008 | Ergonomics of the thermal environment - Methods for the assessment of human responses to contact with surfaces - Part 1: Hot surfaces (ISO 13732-1:2006) |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
EN 14506:2005 | Devices to prevent pollution by backflow of potable water - Automatic diverter - Family H, type C |
ISA MC96.1 : 1982 | TEMPERATURE MEASUREMENT THERMOCOUPLES |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
EN 13959:2004 | Anti-pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D |
EN 200:2008 | Sanitary tapware - Single taps and combination taps for water supply systems of type 1 and type 2 - General technical specification |
ISO 9886:2004 | Ergonomics Evaluation of thermal strain by physiological measurements |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
EN 248:2002 | Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr |