EN 14042:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents
31-10-2003
02-04-2003
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement objectives and strategy
4.1 General
4.2 EN 689
4.3 EN 482
4.4 Other tasks
5 Selection of the measurement procedure or device
5.1 General
5.2 Selection flow chart
5.3 Selectivity requirements
5.4 The influence of environmental parameters
5.5 Fitness for purpose
6 Operating principles and characteristics
6.1 General
6.2 Measurement of chemical agents
6.3 Measurement of airborne micro-organisms and endotoxin
7 Operation of the measuring devices
7.1 Guidance for use of measuring procedures and personal,
portable and transportable measuring devices
7.2 Guidance for use of fixed measuring devices
8 Recommendations on the use of sampling pumps
8.1 General
8.2 Factors influencing the flow rate stability of a pump
8.3 Flow rate calibration
8.4 Calculation of flow rates and sampling volumes
9 Maintenance and calibration
10 Disposal of measuring devices
11 Requirements for training
12 Quality assurance
Bibliography
This European Standard provides guidance on the selection of procedures, and the installation, use and maintenance of devices for the determination of concentrations of chemical or biological agents in workplace atmospheres.This European Standard is based on the guidance given in EN 689 and the requirements of EN 482.Where appropriate, this European Standard specifies additional requirements specific to particular procedures or devices, or classes thereof.It is the user's primary responsibility to choose appropriate procedures or devices that meet the requirements of relevant European Standards. One way of doing this is to obtain information or confirmation from the manufacturer. Type testing, or more generally, the assessment of performance criteria of procedures or devices, can be undertaken by the manufacturer, user, test house or research and development laboratory, as is most appropriate.Although this Standard specifically addresses workplace air, many of the procedures or devices are also relevant to the assessment of air quality in ambient or indoor air.Specific guides exist for electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours in workplace atmospheres (EN 45544-4) and for diffusive samplers for the determination of gases and vapours in ambient air (prEN 13528-3).
Committee |
CEN/TC 137
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DIN EN 14042:2003-07 | Identical |
UNI EN 14042 : 2005 | Identical |
NEN EN 14042 : 2003 | Identical |
SN EN 14042 : 2003 | Identical |
NF EN 14042 : 2003 | Identical |
UNE-EN 14042:2004 | Identical |
I.S. EN 14042:2003 | Identical |
BS EN 14042:2003 | Identical |
PN EN 14042 : 2010 | Identical |
NBN EN 14042 : 2003 | Identical |
NS EN 14042 : 1ED 2003 | Identical |
I.S. CEN/TR 15230:2005 | WORKPLACE ATMOSPHERES - GUIDANCE FOR SAMPLING OF INHALABLE, THORACIC AND RESPIRABLE AEROSOL FRACTIONS |
CEN/TR 15230:2005 | Workplace atmospheres - Guidance for sampling of inhalable, thoracic and respirable aerosol fractions |
PD CEN/TR 15230:2005 | Workplace atmospheres. Guidance for sampling of inhalable, thoracic and respirable aerosol fractions |
ISO 6144:2003 | Gas analysis — Preparation of calibration gas mixtures — Static volumetric method |
EN 12919:1999 | Workplace atmospheres - Pumps for the sampling of chemical agents with a volume flow rate of over 5 l/min - Requirements and test methods |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
ENV 13936 : DRAFT 2001 | WORKPLACE ATMOSPHERES - MEASUREMENT OF CHEMICAL AGENTS PRESENT AS MIXTURES OF AIRBORNE PARTICLES AND VAPOUR - REQUIREMENTS AND TEST METHODS |
ISO 6145-7:2009 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers |
EN 1076:2009 | Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 13890:2009 | Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods |
ISO 6147:1979 | Gas analysis Preparation of calibration gas mixtures Saturation method |
ISO 6143:2001 | Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures |
EN 13098:2000 | Workplace atmosphere - Guidelines for measurement of airborne micro-organisms and endotoxin |
ISO 6879:1995 | Air quality — Performance characteristics and related concepts for air quality measuring methods |
EN 45544-4 : 2016 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4 - GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
ISO 6145-10:2002 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method |
ISO 6145-2:2014 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 2: Piston pumps |
EN 13205:2001 | Workplace atmospheres - Assessment of performance of instruments for measurement of airborne particle concentrations |
ISO 6145-5:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
EN 1231:1996 | Workplace atmospheres - Short term detector tube measurement systems - Requirements and test methods |
ISO 6145-9:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 9: Saturation method |
EN 1540:2011 | Workplace exposure - Terminology |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
EN 1232:1997 | Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods |
EN 45544-4:2016 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 4: Guide for selection, installation, use and maintenance |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.