EN 14154-3:2005+A2:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Water meters - Part 3: Test methods and equipment
01-06-2014
06-04-2011
Foreword
1 Scope
2 Normative references
3 Reference conditions
4 Administrative and external examination for
approval programme
5 Performance tests for approval programme
6 Performance tests related to influence quantities
Annex A (normative) - Irregularity in water velocity
field
Annex B (informative) - Examples of methods and
components used for testing Concentric Water
Meters
Annex C (normative) - Equipment and method used to
determine meter error
Annex D (informative) - Equipment and methods for pressure
loss test
Annex E (informative) - Characteristics of reference devices
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 22/2004/EC on Measuring Instruments
Bibliography
This document applies to water meters intended for residential, commercial, light industrial and industrial use, and specifies the test parameters and the test methods for water meters, irrespective of the design technologies, as specified in EN 14154-1:2005+A2, used to meter the actual volume of clean cold potable water or heated water, flowing through a fully charged, closed conduit. These water meters shall incorporate devices, which indicate the integrated volume.In the case where water meters having a value of Q3 > 160 m3/h, the test schedule may make provisions for modification of the Reference Conditions, to meet individual test laboratory limitations, when testing specifically for endurance or for performance under Influence Quantities.Meters thus tested shall be marked so as to unambiguously indicate part compliance with this document. To augment this marking the meter manufacturer shall, in addition, be obliged to fully disclose the specific non compliance(s) due to the test laboratory limitations.
Committee |
CEN/TC 92
|
DevelopmentNote |
2005 Edition Re-Issued in April 2011 & incorporates AMD 2 2011. (05/2011)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NBN EN 14154-3 : 2005 + A2 2011 | Identical |
UNI EN 14154-3 : 2011 | Identical |
NS EN 14154-3 : 2005 + A2 2011 | Identical |
I.S. EN 14154-3:2005 | Identical |
NF EN 14154-3 : 2005 + A2 2012 | Identical |
UNE-EN 14154-3:2005 | Identical |
NEN EN 14154-3 : 2005 + A2 2011 | Identical |
BS EN 14154-3 : 2005 | Identical |
SN EN 14154-3 : 2005 + A2 2011 | Identical |
PN EN 14154-3 : 2007 + A2 2011 | Identical |
DIN EN 14154-3 E : 2011 | Identical |
BS EN 14154-3:2005+A2:2011 | Identical |
UNE-EN 14154-3:2005+A2:2012 | Identical |
DIN EN 14154-3:2011-06 | Identical |
14/30291768 DC : 0 | BS EN 1434-4 - HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
I.S. EN 14154-4:2014 | WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES |
DIN EN 14154-2:2011-06 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
DIN EN 14154-4:2015-02 | Water meters - Part 4: Additional functionalities |
DIN EN 14268:2005-11 | IRRIGATION TECHNIQUES - METERS FOR IRRIGATION WATER |
BS EN 14154-2 : 2005 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
BS EN 14154-4:2014 | Water meters Additional functionalities |
PREN 1434-4 : DRAFT 2014 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
UNE-EN 14154-1:2005 | Water meters - Part 1: General requirements |
UNE-EN 14154-2:2005 | Water meters - Part 2 : Installation and conditions of use |
UNI EN 14268 : 2006 | IRRIGATION TECHNIQUES - METERS FOR IRRIGATION WATER |
UNI EN 14154-2 : 2011 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
UNI EN 14154-1 : 2011 | WATER METERS - PART 1: GENERAL REQUIREMENTS |
ISO 20456:2017 | Measurement of fluid flow in closed conduits — Guidance for the use of electromagnetic flowmeters for conductive liquids |
BS EN 14268:2005 | Irrigation techniques. Meters for irrigation water |
BS EN 14154-1 : 2005 | WATER METERS - PART 1: GENERAL REQUIREMENTS |
EN 14154-2:2005+A2:2011 | Water meters - Part 2: Installation and conditions of use |
EN 14154-4:2014 | Water meters - Part 4: Additional functionalities |
UNE-EN 14154-4:2015 | Water meters - Part 4: Additional functionalities |
CSA C900.4 : 2013 | HEAT METERS - PART 4: PATTERN APPROVAL TESTS |
UNI EN 14154-4 : 2015 | WATER METERS - PART 4: ADDITIONAL FUNCTIONALITIES |
EN 14154-1:2005+A2:2011 | Water meters - Part 1: General requirements |
DIN EN 14154-1:2011-06 | WATER METERS - PART 1: GENERAL REQUIREMENTS |
EN 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
EN 14154-1:2005+A2:2011 | Water meters - Part 1: General requirements |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
2004/22/EC : 2004 | DIRECTIVE 2004/22/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 31 MARCH 2004 ON MEASURING INSTRUMENTS |
EN 60068-2-64:2008 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO 4064-3:2014 | Water meters for cold potable water and hot water — Part 3: Test report format |
ISO 4064-2:2014 | Water meters for cold potable water and hot water Part 2: Test methods |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 14154-2:2005+A2:2011 | Water meters - Part 2: Installation and conditions of use |
OIML R 49-1 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
OIML R 49-2 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-3-4:2001 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
ISO 4064-1:2014 | Water meters for cold potable water and hot water Part 1: Metrological and technical requirements |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.