Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Determination of the field of extended application
5 Extended application report
6 Classification report
Annex A (normative) - Construction parameter variations
Annex B (normative) - Arrangements for doorsets
        incorporating side and/or over panels
Annex C (informative) - Figures

This European Standard covers single and double leaf, hinged and pivoted, steel based doorsets. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:-integrity (E), integrity/radiation (EW) or integrity/insulation (EI1 or EI2) classification;-door leaf;-ventilation grilles and/or louvres-wall/ceiling fixed elements (frame/suspension system);-glazing for door leaf, side, transom and flush over panels;-items of building hardware;-decorative finishes;-intumescent, smoke, draught or acoustic seals;-alternative supporting construction(s).

Committee
CEN/TC 127
DevelopmentNote
Supersedes PREN 15269-2. (10/2012)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

15/30302476 DC : 0 BS EN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
I.S. EN 13501-2:2016 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
BS EN 13501-2 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
PREN 13501-2 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES

ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1634-2:2008 Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 15269-1:2010 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements
EN 15254-4:2008+A1:2011 Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions