• Shopping Cart
    There are no items in your cart

EN 15269-5:2014+A1:2016

Current

Current

The latest, up-to-date edition.

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows

Published date

12-10-2016

Sorry this product is not available in your region.

This European Standard covers hinged and pivoted steel (any kind) and aluminium based framed, glazeddoorsets or openable windows.This European Standard prescribes the methodology for extending the application of test results obtainedfrom resistance to fire test(s) conducted in accordance with EN 1634-1.Subject to the completion of the appropriate test or tests selected from those identified in Clause 4 theextended application may cover all or some of the following examples: - integrity (E), integrity/radiation (EW) or integrity/insulation (EI1 or EI2) classifications; - doorsets and openable windows; - door / window leaf (leaves); - glazing and non-glazed panels in doorset and openable window; - items of building hardware; - decorative finishes; - intumescent, smoke, draught or acoustic seals; - alternative supporting construction(s).

Committee
CEN/TC 127
DevelopmentNote
Supersedes PREN 15269-5. (06/2014) 2014 Edition Re-Issued in October 2016 & incorporates AMD 1 2016. (10/2016)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

16/30340523 DC : 0 BS EN 17020-4 - EXTENDED APPLICATION OF TEST RESULTS ON DURABILITY OF SELFCLOSING FOR DOORSETS AND OPENABLE WINDOWS - PART 4: DURABILITY OF SELF-CLOSING OF FIRE RESISTANCE HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
I.S. EN 13501-2:2016 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
15/30302476 DC : 0 BS EN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
BS EN 13501-2 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
PREN 13501-2 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES

ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1634-2:2008 Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 15269-1:2010 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.