EN 303-7:2006

Current

Current

The latest, up-to-date edition.

Heating boilers - Part 7: Gas-fired central heating boilers equipped with a forced draught burner of nominal heat output not exceeding 1 000 kW

Published date

11-10-2006

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Constructional and operational requirements
  4.1 General principles
  4.2 Operational requirements
5 Test methods
  5.1 General principles
  5.2 External tightness of the gas line
  5.3 Heat input rates
  5.4 Gas pressure governor
  5.5 Safety of operation
  5.6 Control and safety equipments
  5.7 Combustion
  5.8 Useful efficiencies
  5.9 Condensation
6 Marking and instructions
  6.1 Marking
  6.2 Instructions
  6.3 Presentation
Annex A (informative) Diameters of combustion products
                      evacuation ducts marketed in the
                      various countries
Annex B (informative) Practical method of calibrating the
                      test rig to enable determination of
                      heat loss D[p]
Annex C (informative) Determination of the heat losses from
                      the test rig of the indirect method
                      and the contributions of the
                      circulating pump of the test rig
Annex D (informative) Determination of the operating time at
                      full rate prior to modulation
Annex E (normative) Determination of the combustion
                      characteristics - Carbon monoxide and
                      nitrogen oxides
Annex F (normative) Case of a forced draught burner complying
                      with EN 676
Annex G (informative) Main symbols and abbreviations used
Annex H (informative) A-deviations
Annex ZA (informative) Clauses of this European Standard
                       addressing essential requirements or
                       other provisions of EU Directives
Bibliography

This European Standard specifies the requirements and test methods for the construction, the safety and the rational energy usage for gas-fired central heating boilers equipped with a forced draught burner. These boilers are formed of the assembly of a boiler body and a forced draught gas burner achieved on the production site of the manufacturer, the whole being designed and marketed as a complete boiler. The boiler body shall be in accordance with EN 303-1. The construction of the forced draught gas burner shall be in accordance with EN 676.

Committee
CEN/TC 109
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
NS EN 303-7 : 1ED 2007 Identical
NF EN 303-7 : 2006 Identical
UNI EN 303-7 : 2008 Identical
PN EN 303-7 : 2008 Identical
NBN EN 303-7 : 2007 Identical
NEN EN 303-7 : 2006 Identical
I.S. EN 303-7:2006 Identical
SN EN 303-7 : 2007 Identical
UNE-EN 303-7:2008 Identical
BS EN 303-7:2006 Identical
DIN EN 303-7:2007-05 Identical

S.R. CEN/TR 15316-6-4:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 6-4: EXPLANATION AND JUSTIFICATION OF EN 15316-4-1, MODULE M3-8-1, M8-8-1
PREN 15316-4-1 : DRAFT 2014 HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
S.R. CEN/TR 16787:2014 INDUSTRIAL GAS INSTALLATION - GUIDELINE
EN 15316-4-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1
CEN/TR 16787:2014 Industrial Gas Installation - Guideline
14/30311499 DC : 0 BS EN 15316-4-1 - HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS)
I.S. EN 14394:2006 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
PD CEN/TR 16787:2014 Industrial Gas Installation. Guideline
ISO 13675:2013 Heating systems in buildings — Method and design for calculation of the system energy performance — Combustion systems (boilers)
DIN EN 14394:2008-12 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
UNI EN 14394 : 2008 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREES C
PD CEN/TR 15316-6-4:2017 Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1
CEN/TR 15316-6-4:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 6-4: Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1
BS EN 14394 : 2005 HEATING BOILERS - HEATING BOILERS WITH FORCED DRAUGHT BURNERS - NOMINAL HEAT OUTPUT NOT EXCEEDING 10 MW AND MAXIMUM OPERATING TEMPERATURE OF 110 DEGREE C
BS EN 13836:2006 Gas fired central heating boilers. Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1000 kW
EN 14394:2005+A1:2008 Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C
EN 13836:2006 Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW
DIN EN 15316-4-1:2008-09 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1
12/30239784 DC : 0 BS ISO 13675 - HEATING AND COOLING SYSTEMS IN BUILDINGS - METHOD AND DESIGN FOR CALCULATION OF THE SYSTEM ENERGY PERFORMANCE - COMBUSTION SYSTEMS (BOILERS)
BS ISO 13675:2013 Heating systems in buildings. Method and design for calculation of the system energy performance. Combustion systems (boilers)
I.S. EN 15316-4-1:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1
DIN EN 13836:2007-06 Gas-fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1000 kW

EN 303-1:2017 Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking
EN ISO 3166-1:2014 Codes for the representation of names of countries and their subdivisions - Part 1: Country codes (ISO 3166-1:2013)
EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
EN 334:2005+A1:2009 Gas pressure regulators for inlet pressures up to 100 bar
CEN/TR 1749:2014 European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types)
ISO 3166-1:2013 Codes for the representation of names of countries and their subdivisions Part 1: Country codes
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
EN 88:1991/A1:1996 PRESSURE GOVERNORS FOR GAS APPLIANCES FOR INLET PRESSURE UP TO 200 MBAR

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.