1 Introduction
1.1 Scope
1.2 Object
1.3 Normative references
1.4 Definitions
2 Emission
2.1 General requirements
2.2 Classification of UPS
2.3 General measurement conditions
2.4 Conducted emissions
2.5 Radiated emissions
3 Immunity
3.1 General requirements and performance criteria
3.2 Immunity to electrostatic discharges
3.3 Immunity to radiated electromagnetic fields
3.4 Immunity to fast transients
3.5 Immunity to surges
3.6 Immunity to low frequency signals
Annexes
A (normative) Electromagnetic emission (test methods)
B (informative) Electromagnetic emission - limits
of magnetic field
C (informative) Electromagnetic emission - limits
of signal ports
D (normative) Electromagnetic immunity - test methods
E (normative) Attenuation test method - (under
consideration)
F (informative) Relationship with EU mandate(s)
directive
Applicable to UPS units or UPS systems which include a number of interconnected UPS and associated control/switchgear to form a single power system, for installation in any operator accessible area or in separated electrical locations which are connected to either industrial or public low voltage supply networks. Takes precedence over all aspects of the generic standards and requires no additional testing.
Committee |
TC 22X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
BS EN 50091-2:1996 | Similar to |
VDE 0558-520 : 2006 COR 1 2007 | Identical |
SN EN 50091-2 : 1995 | Identical |
NF EN 50091-2 : 1995 | Similar to |
DIN EN 50091-2 : 1996 | Identical |
I.S. EN 50091-2:1996 | Identical |
NBN EN 50091-2 : 1996 | Identical |
CEI EN 50091-2 : 1ED 1996 | Identical |
NEN EN 50091-2 : 1995 C1 1998 | Identical |
UNE-EN 50091-2 CORR:1999 | Identical |
DD ENV 50091-3:1999 | Specification for uninterruptible power systems (UPS) Performance requirements and test methods |
EN 50091-1-1:1996/corrigendum Aug. 2004 | |
CEI CWA 50487 : 2006 | SMARTHOUSE CODE OF PRACTICE |
CEI UNI EN 45510-2-4 : 2000 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-4: ELECTRICAL EQUIPMENT - HIGH POWER STATIC CONVERTORS |
VDI/VDE 2185 Blatt 1:2007-09 | Radio based communication in industrial automation |
BS IEC 62003:2009 | Nuclear power plants. Instrumentation and control important to safety. Requirements for electromagnetic compatibility testing |
DIN EN 50091-1-1 : 1997 | |
I.S. EN 50091-1-2:2003 | |
EN 45510-2-2:1999 | Guide for procurement of power station equipment - Part 2-2: Electrical equipment - Uninterruptible power supplies |
BS EN 50091-1-2:1999 | General and safety requirements for UPS used in restricted access locationsSpecification for uninterruptible power systems (UPS) |
DIN V ENV 50091-3 : 2000 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: PERFORMANCE REQUIREMENTS |
I.S. EN 50091-1:1993 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - GENERAL AND SAFETY REQUIREMENTS |
BS EN 45510-2-4:2000 | Guide for the procurement of power station equipment Electrical equipment. High power static convertors |
CEI UNI EN 45510-2-3 : 2000 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-3: ELECTRICAL EQUIPMENT - STATIONARY BATTERIES AND CHARGERS |
EN 45510-2-4:2000 | Guide for procurement of power station equipment - Part 2-4: Electrical equipment - High power static convertors |
BS EN 50091-1-1:1997 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
CEI UNI EN 45510-2-2 : 1999 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-2: ELECTRICAL EQUIPMENT - UNINTERRUPTIBLE POWER SUPPLIES |
I.S. EN 50091-1-1:2004 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1-1: GENERAL AND SAFETY REQUIREMENTS FOR UPS USED IN OPERATOR ACCESS AREAS |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
BS EN 45510-2-2:1999 | Guide for the procurement of power station equipment. Electrical equipment Uninterruptible power supplies - Uninterruptible power supplies for power plants |
ENV 50091-3 : 98 AMD 1 99 | UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS |
EN 45510-2-2 : 1999 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2: ELECTRICAL EQUIPMENT - SECTION 2: UNINTERRUPTIBLE POWER SUPPLIES |
EN 50091-1-2 : 98 COR 1 99 |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
EN 60555-2 : 1987 | DISTURBANCES IN SUPPLY SYSTEMS CAUSED BY HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL EQUIPMENT - HARMONICS |
CISPR 16:1987 | CISPR specification for radio interference measuring apparatus and measurement methods |
IEC 60801-1:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment. Part 1: General introduction |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60801-3:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements |
EN 60555-3:1987/A1:1991 | DISTURBANCES IN SUPPLY SYSTEMS CAUSED BY HOUSEHOLD APPLIANCES AND SIMILAR ELECTRICAL EQUIPMENT - VOLTAGE FLUCTUATIONS |
EN 60555-1:1987 | Disturbances in supply systems caused by household appliances and similar electrical equipment - Part 1: Definitions |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.