EN 50131-2-8:2016
Current
The latest, up-to-date edition.
Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors
16-12-2016
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Standard test material
Annex B (normative) - Dimensions and requirements
of the standardized interference test magnets
Annex C (normative) - General Testing Matrix
Annex D (normative) - Spring operated Hammer
Annex E (informative) - Example list of small tools
Annex F (normative) - Minimum performance requirements
gross and shock integration attack tests
Annex G (normative) - Immunity test: Small objects
hit sensitivity
Annex H (normative) - Immunity test: Hard objects
hit sensitivity
Annex I (normative) - Immunity test: Static pressure
sensitivity
Annex J (normative) - Immunity test: Dynamic pressure
sensitivity
Bibliography
This European Standard is for Shock Detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).It specifies four security Grades 1-4 (in accordance with EN 50131-1), specific or non-specific wired or wire-free detectors and uses environmental Classes I-IV (in accordance with EN 50130-5).This European Standard does not include requirements for detectors intended to detect penetration attacks on safes and vaults for example by drilling, cutting or thermal lance.This European Standard does not include requirements for shock detectors intended for use outdoors.A detector needs to fulfil all the requirements of the specified grade.Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions.This European Standard does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130-4.This European Standard does not apply to system interconnections.
Committee |
CLC/TC 79
|
DevelopmentNote |
Supersedes CLC/TS 50131-2-8. (12/2016)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 50131-2-8 : 2017-06 | Identical |
NEN EN 50131-2-8 : 2017 | Identical |
I.S. EN 50131-2-8:2016 | Identical |
SN EN 50131-2-8 : 2016 | Identical |
PN EN 50131-2-8 : 2017 | Identical |
NF EN 50131-2-8 : 2017 | Identical |
BS EN 50131-2-8:2016 | Identical |
VDE 0830-2-2-8 : 2017-06 | Identical |
CEI EN 50131-2-8 : 1ED 2017 | Identical |
UNE-EN 50131-2-8:2017 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN ISO 527-2:2012 | Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:2012) |
ISO 2039-1:2001 | Plastics — Determination of hardness — Part 1: Ball indentation method |
EN ISO 527-1:2012 | Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:2012) |
ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
ISO 2039-2:1987 | Plastics — Determination of hardness — Part 2: Rockwell hardness |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN ISO 2039-1:2003 | Plastics - Determination of hardness - Part 1: Ball indentation method (ISO 2039-1:2001) |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN ISO 2039-2:1999 | Plastics - Determination of hardness - Part 2: Rockwell hardness (ISO 2039-2:1987) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
ISO 527-1:2012 | Plastics Determination of tensile properties Part 1: General principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.