EN 50399 : 2011 AMD 1 2016
Current
The latest, up-to-date edition.
COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS
17-06-2016
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Qualification of test apparatus
6 Test procedure
7 Determination of parameters derived from the test
8 Test report
Annex A (normative) - Calculation of heat release
Annex B (normative) - Smoke production
Annex C (informative) - Additional information on Reynolds
number in Figure 5
Annex D (normative) - Flow distribution inside the duct
Annex E (normative) - Commissioning calibrations
Annex F (informative) - Guidance for calibration procedures
for specific measuring equipment
Annex G (normative) - Calculation of HRR[av], SPR[av]
and FIGRA
Annex H (informative) - Guidance on the choice of test
equipment
Annex I (informative) - Guidance on the file format for
data from the test
Annex J (normative) - Rounding of numbers
Bibliography
This amendment consists of a modification to Subclauses 6.4 and 6.5 to cover the testing of non circular cables and to improve the repeatability and reproducibility of testing of bundles (for cables with a diameter less than or equal to 5,0 mm) and some further improvements based on wider operating experience.
Committee |
CLC/TC 20
|
DocumentType |
Test Method
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 50399 : 2012 AMD 1 2016 | Identical |
NBN EN 50399 : 2011 AMD 1 2016 | Identical |
NEN EN 50399 : 2011 AMD 1 2016 | Identical |
I.S. EN 50399:2011 | Identical |
PN EN 50399 : 2011 AMD 1 2016 | Identical |
DIN EN 50399:2017-02 | Identical |
VDE 0482-399:2017-02 | Identical |
CEI EN 50399/A1:2016 | Identical |
SN EN 50399:2011+A1:2016 | Identical |
UNE-EN 50399:2012 | Identical |
BS EN 50399:2011 | Identical |
15/30329860 DC : 0 | Identical |
ONORM OVE EN 50399 : 2017 | Identical |
S.R. CLC/TS 50576:2016 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
BS EN 50575 : 2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
UNI EN 13501-6 : 2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
UNE-EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
EN 50575:2014/A1:2016 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
I.S. EN 60695-8-2:2017 | FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
CEI CLC/TS 50576 : 2015 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
EN 13501-6:2014 | Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables |
UNE-CLC/TS 50576:2017 | Electric cables - Extended application of test results for reaction to fire |
PREN 50575 : DRAFT 2012 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
IEC TR 60695-8-2:2008 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
I.S. EN 60695-9-2:2014 | FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS |
CEI EN 60695-6-2 : 2013 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS |
PD IEC/TR 62222:2012 | Fire performance of communication cables installed in buildings |
TS 103 247 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); SINGLEMODE OPTICAL FIBRE SYSTEM SPECIFICATIONS FOR HOME CABLING |
17/30361394 DC : 0 | BS EN 50174-1 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
I.S. EN 50575:2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
BS EN 13501-6:2014 | Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables |
PREN 13501-6 : DRAFT 2017 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
I.S. EN 13501-6:2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
I.S. EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
UNE-EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
TS 101 573 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); GENERAL ENGINEERING OF OPTICAL BUILDING CABLING |
17/30348256 DC : 0 | BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
PD CLC/TS 50576:2016 | Electric cables - Extended application of test results for reaction to fire |
DIN EN 13501-6:2014-07 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
12/30259025 DC : 0 | BS EN 50575 - POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
PREN 50174-1 : DRAFT 2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
BS EN 60695-8-2:2017 | Fire hazard testing Heat release. Summary and relevance of test methods |
IEC TR 62222:2012 | Fire performance of communication cables installed in buildings |
12/30252461 DC : DRAFT JAN 2012 | BS EN 13501-6 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
UNE-EN 50575:2015 | Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements |
UNE-EN 60695-6-2:2012 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
13/30277762 DC : 0 | BS EN 60695-8-2 IEC 60695-8-2 ED 1.0 - FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
BS EN 60695-6-2:2011 | Fire hazard testing Smoke obscuration. Summary and relevance of test methods |
PD IEC/TR 60695-8-2:2008 | Fire hazard testing Heat release. Summary and relevance of test methods |
EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
CLC/TS 50576:2016 | Electric cables - Extended application of test results for reaction to fire |
EN ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003) |
ISO 9705:1993 | Fire tests Full-scale room test for surface products |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2003) |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
EN 60332-3-10:2009 | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
EN 14390:2007 | Fire test - Large-scale room reference test for surface products |
EN 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
ISO 3966:2008 | Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.