• EN 60099-5:2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Surge arresters - Part 5: Selection and application recommendations

    Available format(s): 

    Superseded date:  01-03-2018

    Language(s): 

    Published date:  16-08-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General principles for the application of surge
      arresters
    5 Surge arrester fundamentals and applications issues
    6 Insulation coordination and surge arrester
      applications
    7 Surge arresters for special applications
    8 Asset management of surge arresters
    Annex A (informative) - Determination of temporary
            overvoltages due to earth faults
    Annex B (informative) - Current practice
    Annex C (informative) - Arrester modelling techniques
            for studies involving insulation coordination
            and energy requirements
    Annex D (informative) - Diagnostic indicators of
            metal-oxide surge arresters in service
    Annex E (informative) - Typical data needed from arrester
            manufacturers for proper selection of surge
            arresters
    Annex F (informative) - Typical maximum residual
            voltages for metal-oxide arresters without gaps
            according to IEC 60099-4
    Annex G (informative) - Steepness reduction of
            incoming surge with additional line terminal
            surge capacitance
    Annex H (informative) - End of life and replacement
            of old gapped SiC-arresters
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    IEC 60099-5:2013(E) is not a mandatory standard but provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure - rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex H, some aspects regarding the old type of SiC gapped arresters are discussed. This second edition cancels and replaces the first edition published in 1996 and its amendment 1 published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Expanded discussion of different types of arresters and their application, including additions of discussion on transmission of line arresters, arresters for shunt capacitor switching arresters for series capacitor protection, application of arresters between phases connecting arresters in parallel; - Addition of section on asset management, including: managing surge arresters in the power grid, arrester maintenance, significantly expanded discussion of performance diagnostic tools, end-of-life considerations; - New annexes dealing with: arrester modelling for system studies, example of data needed for specifying arresters. Key words: selection and application of surge arrestors, nominal voltages above 1 kV

    General Product Information - (Show below) - (Hide below)

    Development Note Redesignated as EN IEC 60099-5. (03/2018)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 61400-24:2011 Wind turbines - Part 24: Lightning protection
    CEI CLC/TS 50544 : 2011 LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS
    UNE-EN 60099-4:2016 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 60071-5:2015 Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations
    CLC/TS 50544:2010 Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters
    S.R. CLC/TS 50544:2010 LOW VOLTAGE D.C. SURGE PROTECTIVE DEVICE FOR TRACTION SYSTEMS - SELECTION AND APPLICATION RULES FOR SURGE ARRESTERS
    DD CLC/TS 50544:2010 Low voltage d.c. surge protective device for traction systems. Selection and application rules for surge arresters
    S.R. CLC/TS 61643-12:2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES
    DD CLC/TS 61643-12:2009 Low-voltage surge protective devices Surge protective devices connected to low-voltage power distribution systems. Selection and application principles
    BS EN 60071-5:2015 Insulation co-ordination Procedures for high-voltage direct current (HVDC) converter stations
    CEI EN 61400-24 : 2011 WIND TURBINES - PART 24: LIGHTNING PROTECTION
    UNE-CLC/TS 61643-12:2012 Low-voltage surge protective devices -- Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
    CEI EN 60071-2 : 1998 INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE
    BS EN 61400-24:2010 Wind turbines Lightning protection
    I.S. EN 61400-24:2010 WIND TURBINES - PART 24: LIGHTNING PROTECTION
    BS EN 60071-2:1997 Insulation co-ordination Application guide
    EN 61400-24:2010 Wind turbines - Part 24: Lightning protection
    CLC/TS 61643-12 : 2009 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
    IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
    EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    IEC 60099-6:2002 Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
    EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
    EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
    IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective