SECTION ONE - GENERAL
1 Object and scope
2 Characteristics of the test installation to be
   subjected to the tests
3 State of the test installation
4 Shape of the impulse waves
5 Calibration of impulse generator
SECTION TWO - WITHSTAND TESTS
6 Application of the impulses at the level specified
SECTION THREE - TESTS ABOVE THE WITHSTAND LEVEL
7 Application of impulse test above the specified withstand
   level and omission of power-frequency test
8 Procedure for tests above the withstand level

Lays down the conditions and procedure for carrying out impulse tests on cables and their accessories, with a view to rationalizing the practice in different laboratories, and thus to facilitate valid comparisons between the results obtained on cables made to different specifications. Notes: 1.This publication should be read in conjunction with EN 60060 and 60141. 2.For voltage measurements with sphere-gaps, see EN 60052.

Committee
CLC/TC 20
DevelopmentNote
Supersedes HD 48. (06/2002) Redesignated as EN IEC 60230. (03/2018)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NF EN 60230 : 2003 Identical
PN EN 60230 : 2003 Identical
VDE 0481-230 : 2003 Identical
CEI EN 60230 : 2006 Identical
SN EN 60230 : 2002 Identical
IEC 60230:1966 Identical
UNE-EN 60230:2002 Identical
BS EN 60230:2002 Identical
OVE/ONORM EN 60230 : 2003 Identical
NBN EN 60230 : 2002 Identical
DIN EN 60230 : 2003 Identical

BS EN 60229:2008 Electric cables. Tests on extruded oversheaths with a special protective function
CEI EN 60229 : 2010 ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
BS EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
I.S. EN 61442:2005 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
I.S. EN 60229:2008 ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
EN 60229:2008 Electric cables - Tests on extruded oversheaths with a special protective function
EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
ESPECIFICACION UNE 0051:2017 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3).
EA 0051:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
ESPECIFICACION UNE 0052:2017 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
CEI 20-60 : 1999 POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO INCLUDING 20,8/36 (42) KV
UNE-HD 620-10E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5).
UNE-HD 620-9E:2012 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5).
CEI EN 61442 : 2006 TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
EA 0052:2014 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3).
UNE 211632-1:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods
CEI 20-66 : 2010 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
CEI 20-56 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.