EN 60317-46:2014
Current
The latest, up-to-date edition.
Specifications for particular types of winding wires - Part 46: Aromatic polyimide enamelled round copper wire, class 240
14-02-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative reference
3 Terms, definitions, general notes and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion (nominal conductor diameters from
0,250 mm up to and including 2,500 mm)
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 60317-46:2013 specifies the requirements of enamelled round copper winding wire of class 240 with a sole coating of aromatic polyimide resin. The range of nominal conductor diameters covered by this standard is: - grade 1: 0,020 mm up to and including 2,000 mm; - grade 2: 0,020 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - deletion of the 'in some countries' statement in the scope; - new subclause containing general notes on winding wire, formerly a part of the scope; - new subclause containing requirements for appearance; - revision to the notes in Clause 19, Dielectric dissipation factor; - new Clause 23, Pin-hole test. Keywords: requirements of enamelled round copper winding wire, class 240, sole coating of aromatic polyimide resin
Committee |
CLC/TC 55
|
DevelopmentNote |
To be read in conjunction with EN 60317-0-1. (02/2014)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN EN IEC 60317-46 : 2014 | Identical |
PN EN 60317-46 : 2014 | Identical |
CEI EN 60317-46 : 2014 | Identical |
SN EN 60317-46:2014 | Identical |
DIN EN 60317-46:2014-09 | Identical |
NF EN 60317-46 : 2014 | Identical |
IEC 60317-46:2013 | Identical |
NBN EN 60317-46 : 2014 | Identical |
BS EN 60317-46:2014 | Identical |
I.S. EN 60317-46:2014 | Identical |
SN EN 60317-46 : 1997 | Identical |
UNE-EN 60317-46:2014 | Identical |
DS EN 60317-46 : 2014 | Identical |
I.S. EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
CEI EN 60317-50 : 2013 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200 |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
BS EN 61858-1:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS |
BS EN 61858:2008 | Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS |
I.S. EN 60317-50:2012 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200 (IEC 60317-50:2012 (EQV)) |
I.S. EN 61858-1:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 1: WIRE-WOUND WINDING EIS |
UNE-EN 60317-50:2013 | Specifications for particular types of winding wires - Part 50: Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200 |
BS EN 60317-50:2012 | Specifications for particular types of winding wires Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200 |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN 61858-1:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS |
EN 60317-50 : 2012 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 50: GLASS-FIBRE WOUND SILICONE RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED ROUND COPPER WIRE, TEMPERATURE INDEX 200 |
EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
EN 60317-0-1:2014 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
IEC 60317-0-1:2013 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.