• Shopping Cart
    There are no items in your cart

EN 60966-1:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods

Superseded date

11-02-2022

Superseded by

EN IEC 60966-1:2019

Published date

02-06-1999

Sorry this product is not available in your region.

1 Scope
2 Normative References
3 Definitions
4 Design and Manufacturing Requirements
      4.1 Cable design and construction
      4.2 Connector design and construction
      4.3 Outline and interface dimensions
5 Workmanship, marking and packaging
      5.1 Workmanship
      5.2 Marking
      5.3 End caps
      5.4 Packaging and labelling
6 Quality Assessment
7 Test Methods - General
      7.1 Standard atmospheric conditions for testing
      7.2 Visual inspection
      7.3 Dimensions inspection
8 Electrical Tests
      8.1 Reflection properties
      8.2 Uniformity of impedance
      8.3 Insertion loss
      8.4 Insertion loss stability
      8.5 Propagation time
      8.6 Stability of electrical length
      8.7 Phase difference
      8.8 Phase variation with temperature
      8.9 Screening effectiveness
      8.10 Voltage proof
      8.11 Insulation resistance
      8.12 Inner and outer Conductor continuity
      8.13 Void
      8.14 Power rating
      8.15 Intermodulation level measurement
9 Mechanical Robustness Tests
      9.1 Tensile
      9.2 Flexure
      9.3 Flexing endurance
      9.4 Cable assembly crushing
      9.5 Torque
      9.6 Multiple bending
      9.7 Abrasion test of cable assembly
      9.8 Vibrations, shocks and impact
      9.9 Mechanical endurance
10 Environmental Tests
      10.1 Recommended severities
      10.2 Vibration, bumps and shock
      10.3 Climatic sequence
      10.4 Damp heat, steady state
      10.5 Rapid change of temperature
      10.6 Solvents and contaminating fluids
      10.7 Water immersion
      10.8 Salt mist and sulphur dioxide tests
      10.9 Dust tests
      10.10 Flammability
11 Specialized Test Methods
12 Test Schedules
Annex A (normative) Test Methods for Insertion Loss
                    Determination
      A.1 - Purpose
      A.2 - Test Methods
            A.2.1 - Test Method 1
            A.2.2 - Test Method 2
            A.2.3 - Test Method 3
      A.3 - Correction for Characteristic Impedance
            Differences
Annex B (informative) Measuring Methods for Propagation Time
      B.1 - Resonance Method for Propagation Time Measurement
      B.2 - Time Domain Method for Propagation Time Measurement
Annex C (informative) Measurement Method for Screening
                      Effectiveness
      C.1 - Introduction
      C.2 - Test Method
Annex D (informative) Recommended Severities for Environmental
                      Tests
      D.1 - Introduction to the Relationship between
            Environmental Conditions and Test Severities
            D.1.1 - General
            D.1.2 - Environmental Conditions
            D.1.3 - Environmental Testing
      D.2 - Severities for Environmental Testing
            D.2.1 - Vibration
            D.2.2 - Bump
            D.2.3 - Shock
            D.2.4 - Climatic Sequence
            D.2.5 - Damp Heat, Steady State
            D.2.6 - Rapid Change of Temperature
            D.2.7 - Salt Mist
            D.2.8 - Sulphur Dioxide Test
            D.2.9 - Dust Test
Annex E (normative) Quality Assessment
      E.1 - Object
      E.2 - General
            E.2.1 - Related Documents
            E.2.2 - Standards and Preferred Values
            E.2.3 - Marking of the Cable Assembly and
                    Packaging
            E.2.4 - Terminology
      E.3 - Quality Assessment Procedures
            E.3.1 - Procedures for Qualification Approval
            E.3.2 - Procedures for Capability Approval
            E.3.3 - Quality Conformance Inspection
      E.4 - Capability Manual and Approval
            E.4.1 - Responsibilities
            E.4.2 - Contents of the Capability Manual
            E.4.3 - Criteria for Capability Limits
Annex ZA (normative) Normative References to International
                     Publications with their corresponding
                     European Publications
Table D.1 - Relationship between Displacement and Acceleration
Table D.2 - Relationship between Peak Acceleration and Velocity
            Change
Table E.1 - Example of Capability Limits for Cable Assemblies
Table E.2 - Example of Capability Limits for Flexible Cables
Table E.3 - Example of Capability Limits for Connectors
Table E.4 - Example of Flow Chart
Figure 1 - Bending Test: U Shape Assembly
Figure 2 - Bending Test: Straight Assembly
Figure 3 - Twisting Test: U Shape Assembly
Figure 4 - Fixture for Cable Assembly Flexure Test
Figure 5 - Apparatus for Cable Assembly Flexing Endurance Test
Figure 6 - Fixture for Cable Crushing Test
Figure 7 - Multiple Bending Test
Figure 8 - Dust Measuring Device
Figure A.1 - Circuit for the Determination of Insertion Loss
Figure A.2 - Circuit for the Determination of Insertion Loss
Figure A.3 - Alternative Circuit for the Determination of
             Insertion Loss
Figure A.4 - Double-Pass Circuit for the Determination of
             Insertion Loss
Figure B.1 - Arrangement of Test Equipment
Figure C.1 - Line Injection Test Circuit for Coaxial Cable
             Assemblies
Figure C.2 - Schematic Transfer Functions of a Coaxial Cable
             Assembly
Figure C.3 - Complete Installation for Practical Screening
             Effectiveness Measurements
Figure D.1 - Description of Action Needed for the Preparation
             of the Environmental Test Specification

Establishes uniform requirements for testing the electrical, mechanical and climatic properties of r.f. and coaxial cable assemblies composed of cables and connectors operating in the transverse electromagnetic mode (TEM). Tests are described in IEC 61196-1 and IEC 61169-1 respectively.

Committee
CLC/TC 46X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

BS EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
CEI EN 60966-2-6 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
CEI EN 60966-2-3 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-3: DETAIL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-8 CONNECTORS
UNE-EN 50083-2:2013 Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment
EN 60728-4:2008 Cable networks for television signals, sound signals and interactive services - Part 4: Passive wideband equipment for coaxial cable networks
EN 60966-3:2009 Radio frequency and coaxial cable assemblies - Part 3: Sectional specification for semi-flexible coaxial cable assemblies
EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
EN 60966-2-4:2016 Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
EN 60966-4:2003 Radio frequency and coaxial cable assemblies - Part 4: Sectional specification for semi-rigid coaxial cable assemblies
EN 50083-2:2012/A1:2015 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT
BS EN 50529-2:2010 EMC network standard Wire-line telecommunications networks using coaxial cables
I.S. EN 60966-2-6:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
BS EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
I.S. EN 60966-2-1:2009 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-1: SECTIONAL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES
BS EN 60966-2-3:2009 Radio frequency and coaxial cable assemblies Detail specification for flexible coaxial cable assemblies. Frequency range 0 MHz to 1000 MHz, IEC 61169-8 connectors
I.S. EN 60966-2-3:2009 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-3: DETAIL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-8 CONNECTORS
CEI EN 50083-2 : 2012 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT
BS EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors
BS EN 60728-4:2008 Cable networks for television signals, sound signals and interactive services Passive wideband equipment for coaxial cable networks
BS EN 60966-3:2009 Radio frequency and coaxial cable assemblies Sectional specification for semi-flexible coaxial cable assemblies
BS EN 60966-4:2003 Radio frequency and coaxial cable assemblies Sectional specification for semi-rigid coaxial cable assemblies
CEI EN 60966-3 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 3: SECTIONAL SPECIFICATION FOR SEMI-FLEXIBLE COAXIAL CABLE ASSEMBLIES
I.S. EN 50529-2:2010 EMC NETWORK STANDARD - PART 2: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING COAXIAL CABLES
BS EN 60966-2-1:2009 Radio frequency and coaxial cable assemblies Sectional specification for flexible coaxial cable assemblies
CEI EN 60966-2-1 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-1: SECTIONAL SPECIFICATION FOR FLEXIBLE COAXIAL CABLE ASSEMBLIES
BS EN 60966-2-4:2009 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
CEI EN 60966-2-4 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 50083-2:2012 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT
I.S. EN 60966-2-5:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
CEI EN 50529-2 : 2013 EMC NETWORK STANDARD - PART 2: WIRE-LINE TELECOMMUNICATIONS NETWORKS USING COAXIAL CABLES
BS EN 50083-2 : 2012 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT
I.S. EN 60966-2-4:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
CEI EN 60728-4 : 2008 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 4: PASSIVE WIDEBAND EQUIPMENT FOR COAXIAL CABLE NETWORKS
I.S. EN 60966-2-7:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-7: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-47 CONNECTORS
CEI EN 60966-2-5 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 60966-3:2003 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 3: SECTIONAL SPECIFICATION FOR SEMI-FLEXIBLE COAXIAL CABLE ASSEMBLIES
TR 102 864 : 1.1.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); ASSESSMENT OF CABLE EQUIPMENT WITH DIGITAL DIVIDEND; NEW ELECTRONIC COMMUNICATION NETWORKS (ECN) OPERATING IN THE UHF BAND 790 MHZ TO 862 MHZ
TR 102 994 : 1.1.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); IN HOME CABLING FOR INTEGRATED BROADBAND CABLE AND TELEVISION SERVICES
I.S. EN 60728-4:2008 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 4: PASSIVE WIDEBAND EQUIPMENT FOR COAXIAL CABLE NETWORKS
EN 60966-2-1:2009 Radio frequency and coaxial cable assemblies - Part 2-1: Sectional specification for flexible coaxial cable assemblies
EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
EN 60966-2-3:2009 Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors
EN 50529-2:2010 EMC Network Standard - Part 2: Wire-line telecommunications networks using coaxial cables
EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors

IEC 60068-2-68:1994 Environmental testing - Part 2-68: Tests - Test L: Dust and sand
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
ISO 9002:1994 Quality systems — Model for quality assurance in production, installation and servicing
IEC 61169-1:2013 Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
IEC 60068-2-29:1987 Environmental testing. Part 2: Tests. Test Eb and guidance: Bump
IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
IEC 60512-5:1992 Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.