Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General notes on tests
5 Classification
5.1 Classification according to the load
5.2 Classification according to output voltage
6 Marking
6.1 Mandatory marking
6.2 Optional marking
7 Output voltage and current
7.1 Open-circuit voltage
7.2 Voltage during operation
7.3 Voltage surges during switching and operation
7.4 Voltage waveform
7.5 Inrush current
8 Total circuit power
9 Circuit power factor
10 Supply current
11 Impedance at audio-frequencies
12 Operational tests for abnormal conditions
13 Endurance
Annex A (normative) Tests
Annex B (informative) A guide to quoting product life and
failure rate
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Bibliography
This International Standard specifies performance requirements for electronic step-down convertors for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with tungsten halogen lamps as specified in EN 60357 and other filament lamps.
Committee |
CLC/TC 34
|
DevelopmentNote |
To be read in conjunction with EN 61347-1 and EN 61347-2-2. (11/2004)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NEN EN IEC 61047 : 2004 | Identical |
SN EN 61047 : 1992 AMD 2 2001 | Identical |
I.S. EN 61047:2004 | Identical |
IEC 61047:2004 | Identical |
DIN EN 61047 : 2005 | Identical |
NF EN 61047 : 2005 | Identical |
VDE 0712-25 : 2005 | Identical |
BS EN 61047:2004 | Identical |
NBN EN 61047 : 2005 | Identical |
CEI EN 61047 : 2005 | Identical |
UNE-EN 61047:2005 | Identical |
PN EN 61047 : 2005 | Identical |
NEN 11047 : 93 AMD 1 1996 | Identical |
PREN 12665 : DRAFT 2009 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
I.S. EN 61347-2-2:2012 | LAMP CONTROLGEAR - PART 2-2: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS (IEC 61347-2-2:2011 (EQV)) |
CEI EN 61347-2-2 : 2012 | LAMP CONTROLGEAR - PART 2-2: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC STEPDOWN CONVERTORS FOR FILAMENT LAMPS |
DIN EN 12665:2016-09 (Draft) | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
09/30185891 DC : 0 | BS EN 12665 - LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
BS EN 62442-3:2014 | Energy performance of lamp controlgear Controlgear for halogen lamps and LED modules. Method of measurement to determine the efficiency of the controlgear |
BS EN 61347-2-2:2012 | Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
I.S. EN 62442-3:2014 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 3: CONTROLGEAR FOR HALOGEN LAMPS AND LED MODULES - METHOD OF MEASUREMENT TO DETERMINE THE EFFICIENCY OF THE CONTROLGEAR |
UNI EN 12665 : 2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
UNE-EN 12665:2012 | Light and lighting - Basic terms and criteria for specifying lighting requirements |
BS EN 12665:2011 | Light and lighting. Basic terms and criteria for specifying lighting requirements |
UNE-EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
EN 62442-3:2014/A11:2017 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 3: CONTROLGEAR FOR HALOGEN LAMPS AND LED MODULES - METHOD OF MEASUREMENT TO DETERMINE THE EFFICIENCY OF THE CONTROLGEAR |
I.S. EN 12665:2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
IEC 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.