• There are no items in your cart

EN 61223-3-5:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment

Superseded date

02-02-2022

Superseded by

EN IEC 61223-3-5:2019

Published date

23-09-2004

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 General aspects of ACCEPTANCE TESTS
5 Test methods for CT SCANNERS
Annex A (normative) - Terminology - Index of defined terms
Annex B (informative) - Recommended criteria for test results
Annex C (informative) - Visual Method for LOW CONTRAST RESOLUTION
Annex D (informative) - Accuracy of the gantry tilt
Annex E (informative) - DOSE PROFILE
Annex F (informative) - Alternate test methods for
        SPATIAL RESOLUTION
Annex G (informative) - TOMOGRAPHIC SECTION
        THICKNESS for helical scanning
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

This standard - defines the essential parameters which describe the performance of the CT scanners with regard to image quality, patient dose and positioning; - defines the methods of testing the essential parameters; - evaluates compliance with the tolerances of the parameters specified by the accompanying documents. These methods rely mainly on non-invasive measurements, using appropriate test equipment, performed during the installation or after it has been completed. Signed statements covering steps in the installation procedure may be used as part of the acceptance test report. This part of EN 61223 is intended to assist in performing the acceptance tests on a CT scanner. The aim is to verify compliance of the installation with specifications affecting the image quality, patient dose and positioning.

Committee
CLC/TC 62
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

I.S. EN 61223-2-6:2007 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
BS EN 60601-2-68:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
UNE-EN 60601-2-44:2010 Medical electrical equipment -- Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
EN 60601-2-68:2015 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
I.S. EN 60601-2-44:2009 MEDICAL ELECTRICAL EQUIPMENT - PART 2-44: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY
EN 60601-2-44:2009/A2:2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-44: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY (IEC 60601-2-44:2009/A2:2016)
BS EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
BS EN 60601-2-44 : 2009 MEDICAL ELECTRICAL EQUIPMENT - PART 2-44: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY (IEC 60601-2-44:2009)
I.S. EN 60601-2-68:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment

ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
IEC 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60522:1999 Determination of the permanent filtration of X-ray tube assemblies
ISO 5725-3:1994 Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method
ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
ISO 5725-4:1994 Accuracy (trueness and precision) of measurement methods and results Part 4: Basic methods for the determination of the trueness of a standard measurement method
ISO 2092:1981 Light metals and their alloys Code of designation based on chemical symbols
IEC 60601-2-28:2017 Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
IEC 60601-2-32:1994 Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment
ASTM E 1695 : 1995 Standard Test Method for Measurement of Computed Tomography (CT) System Performance
IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments ­ - Part 2­-6: Constancy tests ­ imaging performance of computed tomography X-ray equipment
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras
IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
EN 60601-2-44:2009/A2:2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-44: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY (IEC 60601-2-44:2009/A2:2016)
IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.