EN 61427-2:2015

Current

Current

The latest, up-to-date edition.

Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications

Published date

20-11-2015

Sorry this product is not available in your region.

IEC 61427-2:2015 relates to secondary batteries used in on-grid Electrical Energy Storage (EES) applications and provides the associated methods of test for the verification of their endurance, properties and electrical performance in such applications. The test methods are essentially battery chemistry neutral, i.e. applicable to all secondary battery types. On-grid applications are characterized by the fact that batteries are connected, via power conversion devices, to a regional or nation- or continent-wide electricity grid and act as instantaneous energy sources and sinks to stabilize the grids performance when randomly major amounts of electrical energy from renewable energy sources are fed into it.Related power conversion and interface equipment is not covered by this part of IEC 61427.

Committee
CLC/TC 21X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

IEC 61025:2006 Fault tree analysis (FTA)
EN 60812:2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA)
IEC 62620:2014 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications
IEC 62675:2014 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-metal hydride prismatic rechargeable single cells
EN 62675:2014 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-metal hydride prismatic rechargeable single cells
IEC 62259:2003 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination
IEC 60896-11:2002 Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests
EN 61427-1 : 2013 SECONDARY CELLS AND BATTERIES FOR RENEWABLE ENERGY STORAGE - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: PHOTOVOLTAIC OFF-GRID APPLICATION (IEC 61427-1:2013)
EN 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures
EN 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
IEC 60812:2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA)
IEC 60896-21:2004 Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
EN 62259:2004 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination
EN 62485-3:2014 Safety requirements for secondary batteries and battery installations - Part 3: Traction batteries
IEC 62619:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62485-3:2014 Safety requirements for secondary batteries and battery installations - Part 3: Traction batteries
IEC TR 62060:2001 Secondary cells and batteries - Monitoring of lead acid stationary batteries - User guide
IEC 60896-22:2004 Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements
EN 61025:2007 Fault tree analysis (FTA)
EN 60896-11:2003 Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests
EN 62619:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
EN 62620:2015 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications
EN 60896-22:2004 Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements
IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
IEC 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
EN 60896-21:2004 Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
IEC 62485-2:2010 Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
EN 60730-1:2016 Automatic electrical controls - Part 1: General requirements
IEC 61427-1:2013 Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application
IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements
EN 62133:2013 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.