1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Principle of the test methods
5 Significance and use of the test methods
6 Test apparatus
7 Precautions
8 Specimen preparation
9 Calibration
10 Test apparatus care and maintenance
11 Test procedures
12 Interpretation of results
13 Test report
Annex A (normative) Measurement of char length
Annex B (informative) Logistic regression technique
Annex C (informative) Heat attenuation factor
Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
IEC 61482-1-1:2009 specifies test methods to measure the arc thermal performance value of materials intended for use in heat- and flame-resistant clothing for workers exposed to the thermal effects of electric arcs and the function of garments using these materials. These test methods measure the arc thermal performance value of materials which meet the following requirements: less than 100 mm char length and less than 2 s afterflame after removal from flame, when tested in accordance with ISO 15025, procedure B (bottom-edge ignition) on the outer material, and the char length measured using a modified ISO method as described in Annex A. These methods are used to measure and describe the properties of materials, products, assemblies or garments, in response to convective and radiant energy generated by an electric arc in open air under controlled laboratory conditions. The materials used in these methods are in the form of flat specimens for method A and garments for method B. Method A is used to determine the arc rating of materials and material assemblies when tested in a flat configuration. Method B is used to measure garment response, not arc rating, to an arc exposure including all the garment findings, sewing thread, fastenings, fabrics and other accessories when tested on a male mannequin torso. Method B is also used for accident replication.
Committee |
CLC/TC 78
|
DevelopmentNote |
Supersedes CLC/TS 61482-1. (07/2009)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 61482-1-1 : 2010 | Identical |
CEI EN 61482-1-1 : 2010 | Identical |
NBN EN 61482-1-1 : 2009 | Identical |
NF EN 61482-1-1 : 2009 | Identical |
IEC 61482-1-1:2009 | Identical |
PN EN 61482-1-1 : 2009 | Identical |
UNE-EN 61482-1-1:2010 | Identical |
NEN EN IEC 61482-1-1 : 2009 | Identical |
I.S. EN 61482-1-1:2009 | Identical |
VDE 0682-306-1-1 : 2010 | Identical |
DIN EN 61482-1-1 : 2010 | Identical |
BS EN 61482-1-1:2009 | Identical |
BS EN IEC 60794-2-50:2020 | Identical |
I.S. EN 50110-1:2013 | OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
EN 61482-1-2:2014 | Live working - Protective clothing against the thermal hazards of an electric arc - Part 1-2: Test methods - Method 2: Determination of arc protection class of material and clothing by using a constrained and directed arc (box test) |
BS EN 61482-1-2:2014 | Live working. Protective clothing against the thermal hazards of an electric arc Test methods. Method 2: Determination of arc protection class of material and clothing by using a constrained and directed arc (box test) |
CEI EN 50110-1 : 2014 | OPERATION OF ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
UNE-EN 50110-1:2014 | Operation of electrical installations - Part 1: General requirements |
BS EN 50110-1:2013 | Operation of electrical installations General requirements |
EN 50110-1:2013 | Operation of electrical installations - Part 1: General requirements |
ISO 3175-2:2010 | Textiles Professional care, drycleaning and wetcleaning of fabrics and garments Part 2: Procedure for testing performance when cleaning and finishing using tetrachloroethene |
ISO 6330:2012 | Textiles Domestic washing and drying procedures for textile testing |
ISO 13688:2013 | Protective clothing — General requirements |
EN 61482-1-2:2014 | Live working - Protective clothing against the thermal hazards of an electric arc - Part 1-2: Test methods - Method 2: Determination of arc protection class of material and clothing by using a constrained and directed arc (box test) |
IEC 61482-1-2:2014 | Live working - Protective clothing against the thermal hazards of an electric arc - Part 1-2: Test methods - Method 2: Determination of arc protection class of material and clothing by using a constrained and directed arc (box test) |
ISO 9151:2016 | Protective clothing against heat and flame Determination of heat transmission on exposure to flame |
EN ISO 5077:2008 | Textiles - Determination of dimensional change in washing and drying (ISO 5077:2007) |
ISO 15025:2016 | Protective clothing Protection against flame Method of test for limited flame spread |
IEC 60050-121:1998 | International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism |
EN ISO 15025:2016 | Protective clothing - Protection against flame - Method of test for limited flame spread (ISO 15025:2016) |
EN ISO 6330:2012 | Textiles - Domestic washing and drying procedures for textile testing (ISO 6330:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.