• There are no items in your cart

EN 61663-1 : 1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1 - FIBRE OPTIC INSTALLATIONS

Withdrawn date

01-04-2010

Published date

12-01-2013

Sorry this product is not available in your region.

1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Construction characteristics of the cable
      5.1 General
      5.2 Failure current for buried cables
      5.3 Failure current for aerial cables
6 Need for protection
7 Protective measures
      7.1 General
      7.2 Dielectric or metal-free cables
      7.3 Choice of cable characteristics for both
             buried and aerial installations
      7.4 Use of shield wire for buried cables
      7.5 Route redundancy
Annex A (normative) Frequency of primary failures, Fp for
                    buried and aerial cables and for cables
                    entering a structure exposed to direct
                    lightning strokes
Annex B (normative) Sheath breakdown current ls for both
                    buried and aerial cables
Annex C (normative) Shielding factor values
Annex D (normative) Route redundancy for both buried and
                    aerial cables
Annex E (informative) Damage correction factor Kd
Annex F (informative) Tolerable frequency of primary
                      failures Fa
Annex G (normative) Tests for surge current resistibility
Annex H (informative) Procedure for determining the failure
                      current
Annex I (informative) Bibliography
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Concerned with the lightning protection of telecommunication lines in fibre optic installations. Limits the number of possible primary failures that occur in the optical fibre cable in a specific installation to within values not exceeding the limit value, defined as the tolerable frequency of primary failures.

Committee
TC 81X
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn

EN 50289-4-14:2003 Communication cables - Specifications for test methods - Part 4-14: Environmental test methods - Lightning
I.S. CLC/TR 50450:2006 RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
02/209118 DC : DRAFT SEP 2002 PREN 50289-4-14 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-14: ENVIRONMENTAL TEST METHODS - LIGHTNING
BS EN 187105:2002 Single mode optical cable (duct/direct buried installation)
PD CLC/TR 50450:2006 Resistibility requirements for equipment having (a) telecommunication port(s)
CEI EN 50174-3 : 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
UNE-HD 60364-4-444:2013 Low-voltage electrical installations -- Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
12/30260552 DC : 0 BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
BS EN 50289-4-14:2003 Communication cables. Specifications for test methods. Environmental test methods Lightning
BS EN 61663-2:2001 Lightning protection. Telecommunication lines Lines using metallic conductors
CEI EN 61663-2 : 2003 LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 2: LINES USING METALLIC CONDUCTORS
CLC/TR 50450:2006 Resistibility requirements for equipment having (a) telecommunication port(s)
PREN 50174-3 : DRAFT 2012 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
I.S. EN 50174-3:2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
I.S. HD 60364-4-444:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES
CEI CLC/TR 50450 : 2006 RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
02/637047 DC : DRAFT APR 2002 BS EN 50174-3 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
I.S. EN 187105:2002 SINGLE MODE OPTICAL CABLE (DUCT/DIRECT BURIED INSTALLATION)
I.S. EN 50289-4-14:2003 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-14: ENVIRONMENTAL TEST METHODS - LIGHTNING
BS EN 50174-3 : 2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
EN 187105:2002 Single mode optical cable (duct/direct buried installation)
HD 60364-4-444:2010/AC:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES

IEC 61024-1-1:1993 Protection of structures against lightning - Part 1: General principles - Section 1: Guide A: Selection of protection levels for lightning protection systems
IEC 61024-1:1990 Protection of structures against lightning - Part 1: General principles
IEC 61312-1:1995 Protection against lightning electromagnetic impulse - Part 1: General principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.