EN 62808:2016
Current
The latest, up-to-date edition.
Nuclear power plants - Instrumentation and control systems important to safety - Design and qualification of isolation devices
16-09-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 General principles for isolation devices
6 Isolation device design requirements
7 Qualification test requirements
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 62808:2015 establishes requirements for the design, analysis and qualification of isolation devices used to ensure electrical independence of redundant safety system circuits, or between safety and lower class circuits, as specified in IEC 60709. This standard includes guidance on the determination of the maximum credible fault that is applied to the isolation devices. The maximum credible fault can be used as a basis for the test levels used in testing based on other standards (e.g. IEC TS 61000-6-5 or IEC 62003).
Committee |
CLC/TC 45AX
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
NF EN 62808 : 2016 | Identical |
I.S. EN 62808:2016 | Identical |
NBN EN 62808 : 2016 | Identical |
PN EN 62808 : 2017 | Identical |
VDE 0491-9-3 : 2017 | Identical |
UNE-EN 62808:2016 | Identical |
CEI EN 62808 : 1ED 2017 | Identical |
BS EN 62808:2016 | Identical |
SN EN 62808 : 2016 | Identical |
DIN EN 62808 : 2017 | Identical |
NEN EN IEC 62808 : 2016 | Identical |
IEC 62808:2015+AMD1:2018 CSV | Identical |
PNE-FprEN 62808:2016 | Identical |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 62138:2004 | Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions |
IEC 62003:2009 | Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC TS 61000-6-5:2001 | Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments |
IEC 60880:2006 | Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 60709:2004 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
EN 61513:2013 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
EN 60709:2010 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.