• Shopping Cart
    There are no items in your cart

EN ISO 1452-3:2010

Current

Current

The latest, up-to-date edition.

Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings (ISO 1452-3:2009, corrected version 2010-03-01)

Published date

06-10-2010

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviated terms
4 Material
5 General characteristics
6 Geometrical characteristics
7 Classification and operating conditions
8 Mechanical characteristics
9 Physical characteristics
10 Sealing rings
11 Adhesives
12 Performance requirements
13 Marking
Annex A (normative) - Imperial (inch)-sized fittings
Bibliography

ISO 1452-3:2009 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.In conjunction with ISO 1452-1, ISO 1452-2 and ISO 1452-5, it is applicable to PVC‑U fittings and to joints with components of PVC‑U, other plastics and non-plastics materials intended to be used for the following:- water mains and services buried in the ground;- conveyance of water above ground for both outside and inside buildings;- buried and above ground drainage and sewerage under pressure.It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to components for the conveyance of water and waste water up to and including 45 °C.

Committee
CEN/TC 155
DevelopmentNote
Supersedes EN 1456-1 and EN 1452-3. (01/2010) Supersedes PREN ISO 1452-3. (11/2010)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

11/30239906 DC : 0 BS EN 15014 - PLASTICS PIPING SYSTEMS - BURIED AND ABOVE GROUND PIPING COMPONENTS FOR WATER AND OTHER LIQUIDS UNDER PRESSURE - REQUIREMENTS AND TEST/ASSESSMENT METHODS FOR PIPES AND FITTINGS
17/30363930 DC : 0 BS EN 17176-5 - PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM
17/30363921 DC : 0 BS EN 17176-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
UNI CEN/TS 1452-7 : 2014 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
PREN 17176-3 : DRAFT 2017 PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 3: FITTINGS
UNI EN 14364 : 2013 PLASTICS PIPING SYSTEMS FOR DRAINAGE AND SEWERAGE WITH OR WITHOUT PRESSURE - GLASS-REINFORCED THERMOSETTING PLASTICS (GRP) BASED ON UNSATURATED POLYESTER RESIN (UP) - SPECIFICATIONS FOR PIPES, FITTINGS AND JOINTS
PREN 15014 : DRAFT 2014 PLASTICS PIPING SYSTEMS - BURIED AND ABOVE GROUND PIPING COMPONENTS FOR WATER UNDER PRESSURE - REQUIREMENTS AND TEST/ASSESSMENT METHODS FOR PIPES AND FITTINGS
UNI EN 1796 : 2013 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY WITH OR WITHOUT PRESSURE - GLASS-REINFORCED THERMOSETTING PLASTICS (GRP) BASED ON UNSATURATED POLYESTER RESIN (UP)
DIN EN 12842:2012-11 Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods
DIN EN 14364:2013-05 Plastics piping systems for drainage and sewerage with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) - Specifications for pipes, fittings and joints
I.S. EN 12842:2012 DUCTILE IRON FITTINGS FOR PVC-U OR PE PIPING SYSTEMS - REQUIREMENTS AND TEST METHODS
DIN EN 1796:2013-05 Plastics piping systems for water supply with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP)
I.S. EN 1796:2013 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY WITH OR WITHOUT PRESSURE - GLASS-REINFORCED THERMOSETTING PLASTICS (GRP) BASED ON UNSATURATED POLYESTER RESIN (UP)
I.S. EN 14364:2013 PLASTICS PIPING SYSTEMS FOR DRAINAGE AND SEWERAGE WITH OR WITHOUT PRESSURE - GLASS-REINFORCED THERMOSETTING PLASTICS (GRP) BASED ON UNSATURATED POLYESTER RESIN (UP) - SPECIFICATIONS FOR PIPES, FITTINGS AND JOINTS
DIN CEN/TS 1452-7;DIN SPEC 19675:2014-05 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
PREN 17176-2 : DRAFT 2017 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 2: PIPES
EN 1796:2013 Plastics piping systems for water supply with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP)
UNE-EN 12842:2013 Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods
UNI EN 12842 : 2012 DUCTILE IRON FITTINGS FOR PVC-U OR PE PIPING SYSTEMS - REQUIREMENTS AND TEST METHODS
PD CEN/TS 1452-7:2014 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC-U) Guidance for the assessment of conformity
S.R. CEN/TS 1452-7:2014 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
UNE-EN 1796:2014 Plastics piping systems for water supply with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP)
BS EN 1796:2013 Plastics piping systems for water supply with or without pressure. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP)
UNE-EN 14364:2015 Plastics piping systems for drainage and sewerage with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) - Specifications for pipes, fittings and joints
BS EN 14364:2013 Plastics piping systems for drainage and sewerage with or without pressure. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). Specifications for pipes, fittings and joints
EN 12842:2012 Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods
17/30363924 DC : 0 BS EN 17176-1 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 1: GENERAL
PREN 17176-1 : DRAFT 2017 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 1: GENERAL
EN 14364:2013 Plastics piping systems for drainage and sewerage with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) - Specifications for pipes, fittings and joints
17/30363927 DC : 0 BS EN 17176-3 - PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 3: FITTINGS
14/30297465 DC : 0 BS EN 15014 - PLASTICS PIPING SYSTEMS - BURIED AND ABOVE GROUND PIPING COMPONENTS FOR WATER UNDER PRESSURE - REQUIREMENTS AND TEST/ASSESSMENT METHODS FOR PIPES AND FITTINGS
PREN 17176-5 : DRAFT 2017 PLASTIC PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE GROUND DRAINAGE, SEWERAGE AND IRRIGATION UNDER PRESSURE - ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM
BS EN 12842:2012 Ductile iron fittings for PVC-U or PE piping systems. Requirements and test methods
CEN/TS 1452-7:2014 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 7: Guidance for the assessment of conformity

ISO 580:2005 Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating
ISO 2507-2:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
ISO 2507-1:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method
ISO 1452-1:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: General
ISO 1452-5:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system
ENV 1452-7:2000 Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 7: Guidance for the assessment of conformity
CEN/TR 15438:2007 Plastics piping systems - Guidance for coding of products and their intended uses
EN 802:1994 Plastics piping and ducting systems - Injection-moulded thermoplastics fittings for pressure piping systems - Test method for maximum deformation by crushing
ISO 3126:2005 Plastics piping systems Plastics components Determination of dimensions
ISO 13783:1997 Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure
ISO 7-1:1994 Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes
ISO 1167-3:2007 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 3: Preparation of components
ISO 1183-1:2012 Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method
ISO/TR 4191:2014 Plastics piping systems for water supply Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) Guidance for installation
ISO 7686:2005 Plastics pipes and fittings — Determination of opacity
ISO 1167-1:2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 1: General method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.