Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)

Published date

23-08-2006

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Procedure for preparing the calibration gas mixture
7 Calculation of the volume fraction of the calibration
   component in the gas mixture
8 Determination of the uncertainty in the concentration
   of the calibration component in the gas mixture
Annex A (informative) Example of an apparatus
        suitable for the preparation of calibration gas
        mixtures by the static volumetric method
Annex B (informative) Example of determination
        of the volume of metering syringes
Annex C (informative) Example of the determination
        of the uncertainty in the concentration of a
        calibration gas mixture prepared by the static
        volumetric method
Annex D (informative) Example of the determination
        of the stability, as a function of time, of prepared
        calibration gas mixtures
Bibliography

ISO 6144:2003 specifies a method for the preparation of calibration gas mixtures by a static volumetric method and provides a procedure for calculating the volumetric composition of the mixture. It can be used either with binary gas mixtures (containing one calibration component in a complementary gas, which is usually nitrogen or air) or with mixtures containing more than one component in the complementary gas. This International Standard also specifies how the expanded uncertainty in the volume fraction of each calibration component in the mixture is determined by a rigorous evaluation of all the measurement uncertainties involved, including those associated with the apparatus used for the preparation of the gas mixture and those associated with the experimental procedure itself.

Committee
CEN/TC 238
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

BS EN 61207-1:2010 Expression of performance of gas analyzers General
BS EN 50545-1 : 2011 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
I.S. EN 50545-1:2011 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
BS EN 14626:2012 Ambient air. Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy
I.S. EN 838:2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
EN 61207-1:2010 Expression of performance of gas analyzers - Part 1: General
EN 1076:2009 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods
EN 60079-29-4:2010 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
BS EN 15483:2008 Ambient air quality. Atmospheric measurements near ground with FTIR spectroscopy
DIN EN 1076:2010-04 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods
DIN EN 14212:2012-11 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
DIN EN 14211:2012-11 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
DIN EN 14662-3:2016-02 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATIONS - PART 3: AUTOMATED PUMPED SAMPLING WITH IN SITU GAS CHROMATOGRAPHY
DIN EN 14626:2012-12 Ambient air - Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy
BS EN 14211:2012 Ambient air. Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
UNE-EN 14662-3:2016 Ambient air - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography
I.S. EN 14211:2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE
I.S. EN 14626:2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF CARBON MONOXIDE BY NON-DISPERSIVE INFRARED SPECTROSCOPY
I.S. EN 14212:2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE
I.S. EN 14662-3:2015 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATIONS - PART 3: AUTOMATED PUMPED SAMPLING WITH IN SITU GAS CHROMATOGRAPHY
UNI EN 838 : 2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
VDI 2100 Blatt 3:2011-10 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on adsorbents - Thermal desorption
UNI EN 15483 : 2009 AMBIENT AIR QUALITY - ATMOSPHERIC MEASUREMENTS NEAR GROUND WITH FTIR SPECTROSCOPY
BS EN 60079-29-4:2010 Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases
I.S. EN 15483:2008 AMBIENT AIR QUALITY - ATMOSPHERIC MEASUREMENTS NEAR GROUND WITH FTIR SPECTROSCOPY
BS EN 1076:2009 Workplace exposure. Procedures for measuring gases and vapours using pumped samplers. Requirements and test methods
EN 14662-3:2015 Ambient air - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography
UNI EN 1076 : 2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING PUMPED SAMPLERS - REQUIREMENTS AND TEST METHODS
UNI EN 14626 : 2012 AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF CARBON MONOXIDE BY NONDISPERSIVE INFRARED SPECTROSCOPY
UNI EN 14211 : 2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE
DIN EN 15483:2009-02 AMBIENT AIR QUALITY - ATMOSPHERIC MEASUREMENTS NEAR GROUND WITH FTIR SPECTROSCOPY
UNE-EN 50545-1:2012 Electrical apparatus for the detection and measurement of toxic and combustible gases in car parks and tunnels - Part 1: General performance requirements and test methods for the detection and measurement of carbon monoxide and nitrogen oxides
DIN EN 838:2010-05 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
UNE-EN 14626:2013 Ambient air - Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy
BS EN 14662-3:2015 Ambient air. Standard method for the measurement of benzene concentrations Automated pumped sampling with in situ gas chromatography
UNE-EN 14211:2013 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
BS EN 838:2010 Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods
UNE-EN 14212:2013 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
I.S. EN 1076:2009 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING PUMPED SAMPLERS - REQUIREMENTS AND TEST METHODS
EN 15483:2008 Ambient air quality - Atmospheric measurements near ground with FTIR spectroscopy
EN 14626:2012 Ambient air - Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy
EN 14211:2012 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
BS EN 14212:2012 Ambient air. Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
EN 50545-1:2011/A1:2016 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES
NS-EN 14662-1:2023 Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography

ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
ISO 7504:2015 Gas analysis Vocabulary

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.