GR 1398 CORE : ISSUE 1 REV 1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
GENERIC REQUIREMENTS FOR COAXIAL DROP CABLE
01-06-2014
12-01-2013
Preface
1 Introduction
1.1 Purpose and Scope
1.2 Organization
2 General Information
2.1 Description of Product
2.2 Ordering Options
2.2.1 User Considerations
2.3 Requirements Terminology
2.4 Reference Documents
2.5 Safety Considerations
2.6 Units and Tolerances
2.7 Quality Assurance Programs
3 General Requirements
3.1 Packaging Requirements
3.2 End Sealing
3.3 Marking
3.3.1 Package, Coil, and Reel Marking
3.3.2 Jacket Marking
3.3.3 Length Marking
3.3.4 Jacket Marking Durability
3.4 Compatibility with Hardware
4 Mechanical Design and Test Requirements
4.1 Center Conductor
4.1.1 Copper-Clad Steel Wire
4.1.2 Tensile Strength of Composite Conductor
4.1.3 Elongation of Composite Conductor
4.1.4 Adhesion of Copper
4.1.5 Copper Ductility
4.1.6 Joints
4.2 Dielectric
4.2.1 Material
4.2.2 Shrinkback
4.2.3 Thermal Oxidative Stability - OIT Test
4.2.4 Adhesion
4.2.5 Patching
4.2.6 Insulation Imperfections
4.3 Overall Shield
4.3.1 Laminated Shielding Tape
4.3.2 Braid Wire
4.4 Flooding Compound Under Jacket
4.4.1 Compound Flow
4.4.2 Corrosion Resistance
4.5 Cable Jacket
4.5.1 Jacket Tensile Strength and Elongation
4.5.2 Thermal Oxidative Stability - OIT Test (PE Only)
4.5.3 Ultraviolet Light Stability
4.5.4 Jacket Porosity (PVC Only)
4.5.5 Plasticizer Compatibility (PVC Only)
4.5.6 Jacket Thickness
4.5.7 Jacket Eccentricity
4.5.8 Diameter Over Jacket
4.6 Integral Messenger (IM)
4.6.1 Joints
4.6.2 Messenger Wire Separation
4.7 Gopher Protected (GP) Armor
4.7.1 Armor Construction
4.7.2 Armor
4.7.3 Gopher Resistance Test
4.8 Outer Jacket
5 Completed Cable Physical Tests
5.1 Cold Bend
5.2 Cable Impact Test
5.3 Jacket Longitudinal Shrinkage
5.4 Adhesion of Dielectric to Shield
5.5 Flammability
5.6 Abrasion Resistance
5.7 Compression Resistance
5.8 Water Penetration (Buried Cables Only)
5.9 National Electrical Code Listing
6 Completed Cable Electrical Requirements
6.1 Continuity and Shorts
6.2 Conductor Resistance
6.3 Impedance
6.4 Structural Return Loss (SRL)
6.5 Shielding Effectiveness
6.6 Attenuation
6.7 Dielectric Strength Between Conductors
6.8 Jacket Leakage Test
6.9 Insulation Resistance
Appendix A: Durability of Printing and Marking Test
References
Gives Telcordia's view of generic requirements for coaxial drop cable intended for outdoor use in aerial, underground and buried applications. Coaxial drop cable is constructed with a copper-clad steel center conductor insulated with a suitable polyolefin dielectric material. The satisfactory performance of a coaxial drop cable depends on electrical transmission, physical and environmental conditions, immunity from signal leakage at the wire and connector interface, corrosion-free conditions at the interface, etc.
DevelopmentNote |
Supersedes TR NWT 001398 (03/2004) Incorporated into GR 3175 CORE. (07/2014)
|
DocumentType |
Standard
|
PublisherName |
Telcordia Technologies
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
GR 1503 CORE : ISSUE 1 | GENERIC REQUIREMENTS FOR COAXIAL CONNECTORS (SERIES 59,6,7 AND 11) |
GR 950 CORE : ISSUE 3 | GENERIC REQUIREMENTS FOR OPTICAL NETWORK UNIT (ONU) CLOSURES |
GR 356 CORE : ISSUE 2 | GENERIC REQUIREMENTS FOR OPTICAL CABLE INNERDUCT, ASSOCIATED CONDUIT, AND ACCESSORIES |
GR 2949 CORE : ISSUE 1 | GENERIC REQUIREMENTS FOR BURIED HYBRID COAXIAL/TWISTED PAIR CABLE |
GR 49 CORE : ISSUE 3 | GENERIC REQUIREMENTS FOR OUTDOOR TELEPHONE NETWORK INTERFACE DEVICES (NIDS) |
ASTM D 3349 : 2017 : REDLINE | Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black |
ASTM D 4730 : 2013 : REDLINE | Standard Specification for Flooding Compounds for Telecommunications Wire and Cable |
TR NWT 000421 : ISSUE 3 REV 1 | GENERIC REQUIREMENTS FOR METALLIC TELECOMMUNICATIONS CABLES |
ASTM B 224 : 2016 : REDLINE | Standard Classification of Coppers |
TA NWT 000909 : ISSUE 2 | GENERIC REQUIREMENTS AND OBJECTIVES FOR FIBER IN THE LOOP SYSTEMS |
ASTM A 505 : 2016 : REDLINE | Standard Specification for Steel, Sheet and Strip, Alloy, Hot-Rolled and Cold-Rolled, General Requirements for |
ASTM D 1248 : 2016 : REDLINE | Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable |
GR 1399 CORE : ISSUE 1 REV 1 | GENERIC REQUIREMENTS FOR COAXIAL DISTRIBUTION CABLE |
ASTM D 4566 : 2014 : REDLINE | Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable |
ASTM B 557 : 2015 : REDLINE | Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy Products |
ASTM D 1603 : 2014 : REDLINE | Standard Test Method for Carbon Black Content in Olefin Plastics |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
ASQ Q90:1987 | Quality Management And Quality Assurance Standards - Guidelines For Selection And Use |
ASQ Q94:1987 | Quality Management And Quality System Elements - Guidelines |
ASTM E 8 : 2004 | Standard Test Methods for Tension Testing of Metallic Materials |
GR 492 CORE : ISSUE 2 | GENERIC REQUIREMENTS FOR METALLIC TELECOMMUNICATION WIRE |
ASTM B 193 : 2016 : REDLINE | Standard Test Method for Resistivity of Electrical Conductor Materials |
ASTM D 4565 : 2015 : REDLINE | Standard Test Methods for Physical and Environmental Performance Properties of <brk/>Insulations and Jackets for Telecommunications Wire and Cable |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
ASTM B 479 : 2006 | Standard Specification for Annealed Aluminum and Aluminum-Alloy Foil for Flexible Barrier, Food Contact, and Other Applications (Withdrawn 2015) |
ASTM D 746 : 2014 : REDLINE | Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.