CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
01-05-2011
12-01-2013
1 Scope
2 Single core non-sheathed cable with rigid conductors
for general purposes
3 Single core non-sheathed cable with flexible conductors
for general purposes
4 Single core non-sheathed cable with rigid conductor
for internal wiring
5 Single core non-sheathed cable with flexible conductor
for internal wiring
Annex A (normative) Normative references
Annex B (normative) Requirements for halogens
Annex C (normative) Determination of halogens - Elemental
test
Bibliography
Provides the specifications for single core halogen-free non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V.
Committee |
TC 20
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN VDE 0282-9 : 2007 | Identical |
SN HD 22.9 : 200S3 | Identical |
CEI 20-19/9 V1 : 1999 | Identical |
CEI 20-19/9 : 2008 | Identical |
NBN HD 022.9 : 2007 | Identical |
NEN 3622 : 2001 AMD 1 2004 | Identical |
VDE 0282-9 : 2007 | Identical |
NEN HD 22-9 : 2007 | Identical |
I.S. HD 22.9:2007 | Identical |
PN HD 22.9 : 2007 | Identical |
NFC 32 102-9 : 2007 | Identical |
I.S. EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS IEC 60092-306:2009 | Electrical installations in ships Equipment. Luminaires and lighting accessories |
UNE-IEC 60092-306:2010 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
BS 7211:1998 | Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire |
08/30186163 DC : DRAFT JULY 2008 | BS IEC 60092-306 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 306: EQUIPMENT - LUMINAIRES AND LIGHTING ACCESSORIES |
EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
IEC 60092-306:2009 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
EN 45510-2-9 : 2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
BS EN 45510-2-9:2008 | Guide for procurement of power station equipment Electrical equipment. Cabling systems |
EN 50363-5 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
EN 60332-2-2:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
EN 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
EN 50264-2-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
IEC 60332-2-2:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
EN 50267-2-2:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.