I.S. EN 50090-2-2:1998
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS
Hardcopy , PDF
15-01-2010
English
18-12-1998
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 Scope
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 Topology, cabling and power supply
4.1 Topology
4.2 Cabling
4.3 Power supply
5 Safety
5.1 General
5.2 Electrical safety requirements
5.3 Functional safety
6 Environmental conditions
6.1 General
6.2 Classification of climatic environmental conditions
6.3 Basic requirements and tests based on IEC 68
7 Electromagnetic compatibility requirements for devices
connected to Twisted Pair or coaxial media
7.1 Application area
7.2 Performance criteria
7.3 Immunity test requirements
8 Reliability
Annex A (informative) Certification
Describes the general technical requirements of a Home and Building Electronic System (HBES) based on SELV or PELV.
DevelopmentNote |
1998 Edition is Partially Superseded by I.S. EN 50491-3, I.S. EN50491-5-1, I.S. EN 50491-5-2 & I.S. EN 50491-5-3. (07/2017)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
NF EN 50090-2-2 : 97 AMD 2 2009 | Identical |
EN 50090-2-2:1996/A2:2007 | Identical |
DIN EN 50090-2-2 : 2007 | Identical |
NEN EN 50090-2-2 : 1997 AMD 2 2007 | Identical |
UNE-EN 50090-2-2:1998 | Identical |
BS EN 50090-2-2 : 1997 | Identical |
SN EN 50090-2-2 : 1996 AMD 1 2002 | Identical |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
ENV 61000-2-2 : 1993 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 45011:1998 | General requirements for bodies operating product certification systems (ISO/IEC Guide 65:1996) |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 50090-2-3:2005 | Home and Building Electronic Systems (HBES) - Part 2-3: System overview - General functional safety requirements for products intended to be integrated in HBES |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
EN 45011 : 1998 | GENERAL REQUIREMENTS FOR BODIES OPERATING PRODUCT CERTIFICATION SYSTEMS |
EN 50065-2-1 : 2003 AMD 1 2005 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
HD 21.1 : 200S4 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS |
HD 323.2.30 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2: TESTS - TEST DB AND GUIDANCE: DAMP HEAT, CYCLIC (12 + 12-HOUR CYCLE) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 384.4.43 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PROTECTION FOR SAFETY - CHAPTER 43: PROTECTION AGAINST OVERCURRENT |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
HD 384.5.523 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SECTION 523: CURRENT-CARRYING CAPACITIES IN WIRING SYSTEMS |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 60189-2:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 61196-1:2005 | Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 50090-9-1:2004 | Home and Building Electronic Systems (HBES) - Part 9-1: Installation requirements - Generic cabling for HBES Class 1 Twisted Pair |
HD 21-2 : S3 AMD 1 2002 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - TEST METHODS |
EN 50090-2-1:1994 | Home and Building Electronic Systems (HBES) - Part 2-1: System overview - Architecture |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 29646-1:1992/AC:1994 | INFORMATION TECHNOLOGY - OPEN SYSTEMS INTERCONNECTION - CONFORMANCE TESTING METHODOLOGY AND FRAMEWORK - PART 1: GENERAL CONCEPTS |
EN 45001 : 1989 | GENERAL CRITERIA FOR THE OPERATION OF TESTING LABORATORIES |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.