I.S. EN 50327:2003
Current
The latest, up-to-date edition.
RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
Hardcopy , PDF
English
01-01-2003
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Introduction
1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
3.1 Basic connections of converter groups
3.2 Symbols
3.3 Definitions
4 Service conditions
5 General requirements for converter groups
5.1 Voltage requirements
5.2 Current demand
5.3 Short circuit requirements
5.4 Insulation levels
6 Relationships among parameters of the items of a
converter group
6.1 General
6.2 Theoretical relationships
7 Tests suitable to verify the correct performance of
the converter group
7.1 General
7.2 Performance of tests
7.3 Test schedule
7.4 Loss determination for the converter group
7.5 Power factor measurement
7.6 Measurement of the inherent voltage drop
7.7 Short circuit test
Annex A (informative) Short circuit currents
Annex B (informative) Examples of power factors of
converter groups with d.c. output
Annex C (informative) Interbridge reactor
Bibliography
Covers requirements for some type tests which are significant only when made on the entire group.
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
BS EN 50327:2003 | Identical |
NBN EN 50327 : 2003 AMD 1 2006 | Identical |
EN 50327 : 2003 AMD 1 2005 | Identical |
NF EN 50327 : 2005 AMD 1 2005 | Identical |
DIN EN 50327 : 2006 | Identical |
NEN EN 50327 : 2003 AMD 1 2005 | Identical |
SN EN 50327 : 2003 | Identical |
UNE-EN 50327:2004 | Identical |
EN 50152-3-3:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems - Voltage transformers |
EN 60044-2:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
HD 464 : S1 AMD 5 2002 | DRY-TYPE POWER TRANSFORMERS |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
EN 60076-4:2002 | Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors |
EN 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60044-6 : 1999 | INSTRUMENT TRANSFORMERS - REQUIREMENTS FOR PROTECTIVE CURRENT TRANSFORMERS FOR TRANSIENT PERFORMANCE |
EN 50152-3-2:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
EN 60044-3:2003 | Instrument transformers - Part 3: Combined transformers |
EN 60044-7:2000 | Instrument transformers - Part 7: Electronic voltage transformers |
EN 60289:1994/A11:2002 | REACTORS |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
EN 50123-7-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide |
EN 50121-5:2017 | Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 50328 : 2003 COR 2006 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS |
EN 50123-7-2:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.