I.S. EN 50438:2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
REQUIREMENTS FOR MICRO-GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH PUBLIC LOW-VOLTAGE DISTRIBUTION NETWORKS
Hardcopy , PDF
01-02-2022
English
01-01-2013
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Technical requirements
5 Operation and safety of the micro-generator
6 Commissioning
Annex A (informative) - National settings and requirements
Annex B (informative) - Loss of Mains and overall system
security
Annex C (informative) - Example notification sheets
Annex D (informative) - Compliance type testing
Annex E (informative) - Example test results sheet
Annex F (informative) - Commissioning
Annex G (normative) - Countries allowing extension of the
scope > 16 A
Annex H (informative) - Abbreviations
Annex I (informative) - A-deviations
Bibliography
Defines technical requirements for the protection functions and the operational capabilities of micro-generating plants, designed for operation in parallel with public low-voltage distribution networks.
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NEN EN 50438 : 2013 | Identical |
BS EN 50438:2013 | Identical |
NF EN 50438 : 2014 | Identical |
EN 50438:2013 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC TR 60725:2012 | Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase |
IEC TS 62282-1:2013 | Fuel cell technologies - Part 1: Terminology |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 60255-151:2009 | Measuring relays and protection equipment - Part 151: Functional requirements for over/under current protection |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
IEC 62116:2014 | Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
IEC TR 61000-3-15:2011 | Electromagnetic compatibility (EMC) - Part 3-15: Limits - Assessment of low frequency electromagnetic immunity and emission requirements for dispersed generation systems in LV network |
EN 62116:2014 | Utility-interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60255-127:2010 | Measuring relays and protection equipment - Part 127: Functional requirements for over/under voltage protection |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 60255-151:2009 | Measuring relays and protection equipment - Part 151: Functional requirements for over/under current protection |
HD 60364-5-551:2010/A11:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 50524:2009 | Data sheet and name plate for photovoltaic inverters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.