FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
Hardcopy , PDF
15-05-2016
English
19-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Classification and designation
7 Marking, Labelling and Packaging
Annex A (normative) - Smoke tunnel for smoke response
values
Annex B (normative) - Test aerosol for smoke response
value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Gas test chamber for CO response
threshold value and crosssensitivity to chemical agents
Annex E (normative) - Heat tunnel for heat response value
Annex F (normative) - Measuring instruments for CO
Annex G (informative) - Establishing exposure levels of
chemical agents
Annex H (normative) - Apparatus for dazzling test
Annex I (informative) - Apparatus for impact test
Annex J (normative) - Fire test room
Annex K (normative) - Open wood fire (TF1)
Annex L (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex M (normative) - Glowing smouldering cotton fire (TF3)
Annex N (normative) - Open plastics (polyurethane) fire (TF4)
Annex O (normative) - Liquid (heptane) fire (TF5)
Annex P (normative) - Low temperature black smoke
(decalene) liquid fire (TF8)
Annex Q (informative) - Information concerning the
construction of the smoke tunnel
Annex R (informative) - Information concerning the
construction of the gas test chamber
Annex S (informative) - Construction of the heat tunnel
Annex T (informative) - Information concerning test
procedures and requirements for response to slowly
developing fires, aging and contamination
Annex U (informative) - Information concerning the
construction of the measuring ionization chamber
Bibliography
Defines requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings, incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena.
DevelopmentNote |
2014 Edition Re-Issued in May 2016 & incorporates AMD 1 2016. (05/2016)
|
DocumentType |
Standard
|
Pages |
112
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
EN 54-31:2014+A1:2016 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 54-26:2015 | Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.