I.S. EN 61076-4-103:1999
Current
The latest, up-to-date edition.
CONNECTORS FOR USE IN D.C. LOW-FREQUENCY ANALOGUE AND DIGITAL HIGH SPEED DATA APPLICATIONS - PART 4-103: PRINTED BOARD CONNECTORS WITH ASSESSED QUALITY - DETAIL SPECIFICATION FOR TWO-PART CONNECTORS WITH SHIELDING AND A BASIC GRID OF 2.5 MM
Hardcopy , PDF
English
01-01-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 General data
1.1 Recommended method of mounting
1.1.1 Number of contacts and contact cavities
1.2 Ratings and characteristics
1.3 Normative references
1.4 Marking
1.5 IEC type designation
1.6 Ordering information
2 Technical data
2.1 Definitions
2.1.1 Mechanical features
2.1.2 Contacts and terminations
2.1.3 Engagement sequence
2.1.4 Mechanical coding
2.2 Survey of styles and variants
2.2.1 Styles of connectors
2.2.2 Survey of termination variants
2.2.3 Survey of cable diameters
2.3 Information of application
2.3.1 Complete connectors (pairs)
2.3.2 Fixed board connectors
2.3.3 Free cable connectors
2.3.4 Coding device
2.3.5 Shielding and grounding
2.4 Survey of contact arrangements
3 Dimensional information
3.1 General
3.2 Isometric view and common features
3.2.1 Common features
3.2.2 Reference system
3.2.3 Height dimensions
3.2.4 Width dimensions
3.2.5 Depth dimensions
3.3 Mating information
3.3.1 Engaging direction
3.3.2 Perpendicular to the engaging direction
3.3.3 Inclination
3.4 Fixed board connectors
3.4.1 Dimensions of connector shrouds
3.4.2 Dimensions of contacts
3.4.3 Terminations
3.5 Free cable connectors
3.5.1 Dimensions of cable connectors
3.5.2 Dimensions of contacts
3.5.3 Terminations
3.6 Accessories
3.6.1 Default coding configuration
3.7 Mounting information for fixed board connectors
3.8 Gauges
3.8.1 Sizing gauges and retention force gauges
3.8.2 Test gauge for first contact point
3.8.3 Test gauge for static load
4 Characteristics
4.1 Climatic category
4.2 Electrical characteristics
4.2.1 Creepage and clearance distances
4.2.2 Voltage proof
4.2.3 Current-carrying capacity
4.2.4 Contact resistance
4.2.5 Insulation resistance
4.3 Mechanical characteristics
4.3.1 Mechanical operation
4.3.2 Engaging and separating forces
4.3.3 Contact retention in insert
4.3.4 Static load, transverse
4.3.5 Gauge retention force
4.3.6 Vibration (sinusoidal)
4.3.7 Shock
4.3.8 Polarizing method
4.3.9 Robustness and effectiveness of coding devices
4.3.10 Insert retention in housing (axial)
4.3.11 Cable clamp resistance to cable rotation
4.3.12 Effectiveness of connector coupling devices
4.3.13 Shielding contact spring holding force
4.4 Electromagnetic compatibility (EMC)
4.4.1 Shielding effectiveness of connectors
4.4.2 Electrostatic discharge (ESD)
5 Test schedule
5.1 General
5.1.1 Arrangement for contact resistance measurements
5.1.2 Arrangement for dynamic stress tests
5.1.3 Arrangement for testing static load, transverse
5.1.4 Arrangement for voltage proof and polarization voltage
5.1.5 Arrangement for flammability test
5.1.6 Arrangement for shielding effectiveness test
5.1.7 Arrangement for electrostatic discharge test
5.2 Test schedule tables
5.2.1 Group P - Preliminary
5.2.2 Group A - Dynamic/climatic
5.2.3 Group B - Mechanical endurance
5.2.4 Group C - Moisture
5.2.5 Group D - Electrical load
5.2.6 Group E - Mechanical resistivity
5.2.7 Group F - Chemical resistivity
5.2.8 Group G - Connections
6 Quality assessment procedures
6.1 Qualification approval testing
6.1.1 Method 1
6.1.2 Method 2
6.2 Quality conformance inspection
6.2.1 Lot-by-lot tests
6.2.2 Periodic tests
6.3 Delayed delivery, re-inspection
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Gives the number QC 480301XX0004 which is the specification number in the IEC Quality Assessment System for Electronic Components (IECQ).
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
142
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
SN EN 61076-4-103 : 1999 | Identical |
EN 61076-4-103:1999 | Identical |
BS EN 61076-4-103:1999 | Identical |
DIN EN 61076-4-103:1999-08 | Identical |
IEC 61076-4-103:1999 | Identical |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60917-2-2:1996 | Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Section 2: Detail specification - Dimensions for subracks, chassis, backplanes, front panels and plug-in units |
IEC 60512-8:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 8: Connector tests (mechanical) and mechanical tests on contacts and terminations |
IEC 61076-4-100:2001 | Connectors for electronic equipment - Part 4-100: Printed board connectors with assessed quality - Detail specification for two-part connector modules having a grid of 2,5 mm for printed boards and backplanes |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60512-7:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests |
EN 61076-4:1996 | Connectors with assessed quality, for use in d.c., low frequency analogue and in digital high-speed data applications - Part 4: Sectional specification - Printed board connectors |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 61076-4-100:2001 | Connectors for electronic equipment - Part 4-100: Printed board connectors with assessed quality - Detail specification for two-part connector modules having a grid of 2,5 mm for printed boards and backplanes |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60352-5:2012/AC:2014 | SOLDERLESS CONNECTIONS - PART 5: PRESS-IN CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE (IEC 60352-5:2012) |
ISO 468:1982 | Surface roughness — Parameters, their values and general rules for specifying requirements |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
IEC 61076-4:1995 | Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications - Part 4: Sectional specification - Printed board connectors |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60512-4:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 4: Dynamic stress tests |
EN 60917:1990/A1:1994 | MODULAR ORDER FOR THE DEVELOPMENT OF MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT PRACTICES |
IEC 60917-2-2:1994 | Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Section 2: Detail specification - Dimensions for subracks, chassis, backplanes, front panels and plug-in units |
IEC 60512-9:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 9: Miscellaneous tests |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60512-23-3:2000 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 23-3: Test 23c: Shielding effectiveness of connectors and accessories |
IEC 60512-3:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 3: Current-carrying capacity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.