FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols, abbreviated terms and
conventions
4 Overview of SDCI (IO-Link[TM])
5 Physical Layer (PL)
6 Standard Input and Output (SIO)
7 Data link layer (DL)
8 Application layer (AL)
9 System management (SM)
10 Device
11 Master
Annex A (normative) - Codings, timing constraints,
and errors
Annex B (normative) - Parameter and commands
Annex C (normative) - ErrorTypes (ISDU errors)
Annex D (normative) - EventCodes (diagnosis information)
Annex E (normative) - Data types
Annex F (normative) - Structure of the Data Storage
data object
Annex G (normative) - Master and Device conformity
Annex H (informative) - Residual error probabilities
Annex I (informative) - Example sequence of an ISDU
transmission
Annex J (informative) - Recommended methods for detecting
parameter changes
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes a single-drop digital communication interface technology for small sensors and actuators SDCI (commonly known as IO-Link[TM]2), which extends the traditional digital input and digital output interfaces as defined in IEC 61131-2 towards a pointto-point communication link.
| DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
584
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Current
|
| SupersededBy |
| Standards | Relationship |
| EN 61131-9:2013 | Identical |
| BS EN 61131-9:2013 | Equivalent |
| EN 61076-2-101:2012 | Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking |
| IEC 61158-2:2014 | Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition |
| ISO/IEC 7498-1:1994 | Information technology — Open Systems Interconnection — Basic Reference Model: The Basic Model |
| ISO/IEC 10646:2014 | Information technology — Universal Coded Character Set (UCS) |
| EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
| IEC 61131-1:2003 | Programmable controllers - Part 1: General information |
| EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
| EN 61131-1:2003 | Programmable controllers - Part 1: General information |
| IEC TR 62453-61:2009 | Field device tool interface specification - Device Type Manager (DTM) Styleguide for common object model |
| IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
| IEC TR 62390:2005 | Common automation device - Profile guideline |
| ISO/IEC 2022:1994 | Information technology — Character code structure and extension techniques |
| EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| ISO/IEC 10731:1994 | Information technology — Open Systems Interconnection — Basic Reference Model — Conventions for the definition of OSI services |
| EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
| EN 60947-5-2:2007/A1:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-2: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - PROXIMITY SWITCHES (IEC 60947-5-2:2007/A1:2012) |
| EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
| EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
| IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
| ISO 1177:1985 | Information processing — Character structure for start/stop and synchronous character oriented transmission |
| ISO/IEC 646:1991 | Information technology — ISO 7-bit coded character set for information interchange |
| IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
| EN 61000-4-4:2012 | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
| IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
| IEC 61076-2-101:2012 | Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking |
| IEC 60870-5-1:1990 | Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats |
| IEEE 754-2008 REDLINE | IEEE Standard for Floating-Point Arithmetic |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.