I.S. EN 61325:1997
Current
The latest, up-to-date edition.
INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
Hardcopy , PDF
English
01-01-1997
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
SECTION 1: GENERAL
1 Scope
2 Normative references
3 Definitions
SECTION 2: INSULATORS
4 Insulator classes and type
5 Insulating materials
6 Specified characteristics and features of a d.c. insulator unit
7 Identification of insulators
SECTION 3: CLASSIFICATION OF TESTS, SAMPLING RULES AND PROCEDURES
8 Classification of tests
8.1 Type Tests
8.2 Sample Tests
8.3 Routine tests
9 Quality assurance
10 Procedures for type and sample tests
10.1 Insulator selection for type tests
10.2 Sampling rules and procedures for sample tests
10.3 Re-test procedure for the sample tests
SECTION 4: TEST PROCEDURES FOR ELECTRICAL TESTS
11 General requirements for high-voltage tests
12 Standard atmospheric conditions and correction factors
for electrical tests
12.1 Standard reference atmosphere
12.2 Correction factors for atmospheric conditions
13 Mounting arrangements for electrical tests
14 Lightning impulse voltage tests
14.1 Test procedure
14.2 Acceptance criteria
15 Dry d.c. voltage tests
15.1 Test procedure
15.2 Acceptance criteria
16 SF6 puncture withstand test
16.1 Test method
16.2 Acceptance criteria
17 Impulse overvoltage puncture withstand test
18 Ion migration test
18.1 Reference conditions used to calculate the expected charge
18.2 Test validity
18.3 Test procedure
18.4 Acceptance criteria
19 Electrical body resistance test
19.1 Test procedure
19.2 Acceptance criteria
20 Thermal runaway test
20.1 Duration
20.2 Procedure
20.3 Acceptance criteria
21 Routine electrical test
SECTION 5: TEST PROCEDURES FOR MECHANICAL AND OTHER TESTS
22 Verification of the dimensions
23 Electromechanical failing load test
23.1 Test procedure
23.2 Acceptance criteria
23.3 Coefficient for type tests
23.4 Coefficients for sample tests
24 Mechanical failing load test
24.1 Test procedure
24.2 Acceptance criteria
25 Thermal-mechanical performance test
25.1 Test procedure
25.2 Acceptance criteria
26 Residual mechanical strength test
26.1 Previous tests
26.2 Preparation of the test pieces
26.3 Test procedure
26.4 Test results
26.5 Acceptance criteria for the type test
26.6 Acceptance criteria for the sample test
26.7 Comparison between type and sample test results
27 Verification of the axial, radial and angular displacements
27.1 Test procedure
27.2 Acceptance criteria for cap and pin insulators
27.3 Acceptance criteria for long rod insulators
28 Verification of the locking system
28.1 Conformity of the locking device
28.2 Verification of locking
28.3 Position of the locking device
28.4 Procedure for the operation test
28.5 Acceptance criteria for the operation test
29 Temperature cycle test
29.1 Test procedure for string insulator units composed
of ceramic material
29.2 Special test procedure for insulators with thick
sections or very large insulators
29.3 Complementary specifications
29.4 Acceptance criteria
30 Thermal shock test
30.1 Test procedure
30.2 Acceptance criteria
31 Porosity test
31.1 Test procedure
31.2 Acceptance criteria
32 Galvanizing test
32.1 Test procedures
32.2 Acceptance criteria
33 Routine visual inspection
33.1 Insulators with ceramic insulating parts
33.2 Insulators with glass insulating parts
34 Routine mechanical test
35 Zinc sleeve test
35.1 General requirements concerning the zinc sleeve
35.2 Type test procedure
35.3 Sample test procedure
36 Zinc collar test
36.1 General requirements for zinc collar
36.2 Type and sample test procedure
SECTION 6: TESTS ON STRING INSULATOR UNITS
37 General
Tables
Figures
Annexes
A - Method of comparison of the results of the electromechanical
or mechanical failing load type and sample tests
B - Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Applies to string insulator units of ceramic material or glass for use on d.c. overhead power lines with a nominal voltage greater than 1000 V.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
104
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
BS EN 61325:1996 | Identical |
DIN EN 61325 : 1996 | Identical |
NBN EN 61325 : 1996 | Identical |
NF EN 61325 : 1995 | Identical |
SN EN 61325 : 1995 | Identical |
UNE-EN 61325:1997 | Identical |
EN 61325:1995 | Identical |
IEC 61325:1995 | Identical |
ISO 9004-1:1994 | Quality management and quality system elements Part 1: Guidelines |
IEC 60305:1995 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type |
ISO 3951:1989 | Sampling procedures and charts for inspection by variables for percent nonconforming |
ISO 9004-3:1993 | Quality management and quality system elements — Part 3: Guidelines for processed materials |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 60383-1:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 60672-3:1997 | Ceramic and glass-insulating materials - Part 3: Specifications for individual materials |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC 61211:2004 | Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1 000 V - Impulse puncture testing in air |
IEC TR 60797:1984 | Residual strength of string insulator units of glass or ceramic material for overhead lines after mechanical damage of the dielectric |
ISO 9004-2:1991 | Quality management and quality system elements Part 2: Guidelines for services |
HD 474 : 200S1 | DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS |
ISO 9000-2:1997 | Quality management and quality assurance standards — Part 2: Generic guidelines for the application of ISO 9001, ISO 9002 and ISO 9003 |
IEC 60437:1997 | Radio interference test on high-voltage insulators |
ISO 1459:1973 | Metallic coatings — Protection against corrosion by hot dip galvanizing — Guiding principles |
IEC TS 61245:2015 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems |
IEC 60372:1984 | Locking devices for ball and socket couplings of string insulator units - Dimensions and tests |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
ISO 9003:1994 | Quality systems Model for quality assurance in final inspection and test |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
IEC 60433:1998 | Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60120:1984 | Dimensions of ball and socket couplings of string insulator units |
ISO 2064:1996 | Metallic and other inorganic coatings — Definitions and conventions concerning the measurement of thickness |
ISO 9000-1:1994 | Quality management and quality assurance standards — Part 1: Guidelines for selection and use |
IEC 60383-2:1993 | Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria |
IEC 60672-1:1995 | Ceramic and glass insulating materials - Part 1: Definitions and classification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.