INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Heating of built-in and independent starting devices
16 Pulse voltage of ignitors
17 Mechanical strength
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annex A (normative) - Test to establish whether a conductive
part is a live part which may cause an electric shock
Annex B (normative) - Particular requirements for thermally
protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
lamp controlgear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the
heating tests of thermally protected lamp
controlgear
Annex E (normative) - Use of constant S other than 4500 in t[w]
tests
Annex F (normative) - Draught-proof enclosure
Annex G (informative) - Explanation of the derivation of the
values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Mechanical strength testing
Annex J (normative) - Precautions to be observed when measuring
with sphere-gaps
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps.
| DevelopmentNote |
Together with I.S. EN 61347-1 and parts 2-2, 2-3, 2-4, 2-5, 2-6, 2-7, 2-8 and 2-9 of I.S. EN 61347 supersedes I.S. EN 60920, I.S. EN 60922, I.S. EN 60924, I.S. EN 60926, I.S. EN 60928 and I.S. EN 61046. (07/2005) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
78
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| BS EN 61347-2-1 : 2001 | Identical |
| EN 61347-2-1:2001/A2:2014 | Identical |
| NF EN 61347-2-1 : 2001 AMD 2 2014 | Identical |
| DIN EN 61347-2-1 : 2014 | Identical |
| UNE-EN 61347-2-1:2002 | Identical |
| IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
| EN 60052:2002 | Voltage measurement by means of standard air gaps |
| EN 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
| EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
| EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| IEC 60730-2-3:2006 | Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps |
| IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
| IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
| IEC 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
| IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
| EN 61199:2011/A2:2015 | SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61199:2011/A2:2014) |
| IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
| IEC 60929:2011+AMD1:2015 CSV | AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements |
| IEC 60695-2-10:2000 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
| EN 60255-8:1998 | Electrical relays - Part 8: Thermal electrical relays |
| IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
| IEC 61167:2015 | Metal halide lamps - Performance specification |
| IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
| IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
| IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
| IEC 60317-0-1:2013 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
| EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60691:2015 | Thermal-links - Requirements and application guide |
| IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
| ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
| IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
| IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
| IEC 60255-8:1990 | Electrical relays - Part 8: Thermal electrical relays |
| IEC 60052:2002 | Voltage measurement by means of standard air gaps |
| EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
| IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
| IEC 60155:1993 | Glow-starters for fluorescent lamps |
| IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
| ISO 3864:1984 | Safety colours and safety signs |
| IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
| EN 61195:1999/A2:2015 | DOUBLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61195:1999/A2:2014) |
| IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
| IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-