I.S. EN 61347-2-2:2012
Current
The latest, up-to-date edition.
LAMP CONTROLGEAR - PART 2-2: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS (IEC 61347-2-2:2011 (EQV))
Hardcopy , PDF
English
01-01-2012
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Transformer heating
16 Construction
17 Creepage distances and clearances
18 Screws, current-carrying parts and connections
19 Resistance to heat, fire and tracking
20 Resistance to corrosion
Annex A (normative) - Test to establish whether a
conductive part is a live part which may
cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means of
protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected
lamp controlgear
Annex E (normative) - Use of constant S other than
4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation
of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Particular additional requirements
for SELV d.c. or a.c. supplied electronic
step-down convertors for filament lamps
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1000 V at 50 Hz or 60 Hz and rated output voltage <= 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps.
DevelopmentNote |
Together with I.S. EN 61347-1 and parts 2-1, 2-3, 2-4, 2-5, 2-6, 2-7, 2-8 and 2-9 of I.S. EN 61347 supersedes I.S. EN 60920, I.S. EN 60922, I.S. EN 60924, I.S. EN 60926, I.S. EN 60928 & I.S. EN 61046. (07/2005) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
19
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 61347-2-2 : 2012 | Identical |
SN EN 61347-2-2 : 2001 AMD 2 2006 | Identical |
BS EN 61347-2-2:2012 | Identical |
EN 61347-2-2:2012 | Identical |
UNE-EN 61347-2-2:2012 | Identical |
NF EN 61347-2-2 : 2012 | Identical |
IEC 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61558-2-16:2009/A1:2013 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013) |
EN 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 61558-2-13:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers |
IEC 61558-2-16:2009+AMD1:2013 CSV | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.