I.S. EN 61642:1999
Current
The latest, up-to-date edition.
INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS
Hardcopy , PDF
English
01-01-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
1.4 General considerations
1.4.1 AC harmonics
1.4.2 Reactive power
2 Resonance problems and solutions
2.1 Introduction
2.2 Supply impedance view, load-busbar impedance view
2.3 Example of series resonance
2.4 Example of parallel resonance
2.5 Solutions to avoid resonances
2.5.1 Capacitor-reactor connection: series resonance
2.5.2 Capacitor-reactor connection: parallel resonance
3 Shunt capacitors and filters for networks having a voltage
up to and including 1 000 V
3.1 Introduction
3.2 Shunt capacitors
3.3 Detuned filter
3.4 Tuned filter
3.5 Components selection
3.5.1 Capacitors
3.5.2 Reactors
3.5.3 Contactors and/or circuit-breakers
3.5.4 Short-circuit protection (fuses)
3.6 Disturbance of ripple control installations by shunt
capacitors and filters
3.6.1 Shunt capacitors
3.6.2 Detuned filter
3.6.3 Tuned filter
4 Shunt capacitors and filters for networks having a voltage
above 1 000 V
4.1 Introduction
4.2 Specific requirements
4.3 Choice of power factor correction installation
4.4 Type of filters
4.5 Filter components selection
4.5.1 Circuit-breaker
4.5.2 Capacitors
4.5.3 Reactors
4.5.4 Resistors
4.5.5 Relay protection
4.6 Disturbance of ripple control installations by shunt
capacitors and filters
Annex A - Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Covers guidance for the use of passive a.c. harmonic filters and shunt capacitors for the limitation of harmonics and power factor correction intended to be used in industrial applications, at low and high voltages.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
IEC 61642:1997 | Identical |
SN EN 61642 : 1997 | Identical |
DIN EN 61642 : 1998 | Identical |
BS EN 61642:1998 | Identical |
NF EN 61642 : 1998 | Identical |
EN 61642:1997 | Identical |
NBN EN 61642 : 1998 | Identical |
HD 525.2 : S1 AMD 1 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - ENDURANCE TESTING |
IEC 60252:1993 | A.C. motor capacitors |
IEC 60050-131:2002 | International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory |
EN 60252 : 94 AC 94 | A.C. MOTOR CAPACITORS |
IEC 60107-1:1997 | Methods of measurement on receivers for television broadcast transmissions - Part 1: General considerations - Measurements at radio and video frequencies |
EN 60265-2:1993/A2:1998 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
ENV 61000-2-2 : 1993 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
HD 597 S1:1992/corrigendum:1992 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS |
IEC 60265-2:1988 | High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 60282-1:2009+AMD1:2014 CSV | High-voltage fuses - Part 1: Current-limiting fuses |
IEC 60549:2013 | High-voltage fuses for the external protection of shunt capacitors |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
HD 207 : 200S1 | RECOMMENDATION FOR CAPACITORS FOR INDUCTIVE HEAT GENERATING PLANTS OPERATING AT FREQUENCIES BETWEEN 40 AND 24 000 HZ |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
EN 61049:1993 | Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements |
EN 60931-1:1996/A1:2003 | SHUNT POWER CAPACITORS OF THE NON-SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1 KV - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
EN 60289:1994/A11:2002 | REACTORS |
IEC 60291:1969 | Fuse definitions |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
IEC 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General |
EN 60831-1:2014/AC:2014 | SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION |
IEC 60143:1972 | Series capacitors for power systems |
HD 348 : 200S7 | HIGH-VOLTAGE ALTERNATING-CURRENT CIRCUIT-BREAKERS |
HD 355.1 : 200S3 | HIGH VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES ABOVE 1 KV AND LESS THAN 52 KV |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60831-1:2014 RLV | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation |
IEC 60050-436:1990 | International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors |
EN 60282-1:2009/A1:2014 | HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009) |
HD 525.1 : S1 AMD 1 | SHUNT CAPACITORS FOR A.C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY |
EN 60143 : 93 AC 94 | SERIES CAPACITORS FOR POWER SYSTEMS - GENERAL PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION |
HD 536 : 200S1 | TEST REQUIREMENTS FOR THE EVALUATION OF THE EMISSION OF IONIZED GASES DURING SHORT CIRCUIT TESTS OF RESIDUAL CURRENT OPERATED CIRCUIT BREAKERS FOR HOUSEHOLD AND SIMILAR USE |
IEC 60110:1973 | Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz |
IEC 60289:1988 | Reactors |
IEC TS 60871-2:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 2: Endurance testing |
IEC 60242:1967 | Standard frequencies for centralized network control installations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.