I.S. EN 62040-5-3:2017
Current
The latest, up-to-date edition.
UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
5 Electrical conditions, performance and declared values
6 DC UPS tests
Annex A (informative) - DC UPS configurations
Annex B (informative) - Topologies - DC UPS
Annex C (informative) - Purchaser specification guidelines
Annex D (normative) - Input mains failure - Test method
Annex E (informative) - Dynamic output performance - Measurement
techniques
Annex F (normative) - DC UPS efficiency - Methods of
measurement
Annex G (informative) - Climatic test
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines performance and test requirements of a complete DC UPS and not of individual DC UPS functional units.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (03/2017)
|
DocumentType |
Standard
|
Pages |
148
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 62040-5-3:2017 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60034-22:2009 | Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC TR 60721-4-0:2002 | Classification of environmental conditions - Part 4-0: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Introduction |
IEC TR 60721-4-3:2001+AMD1:2003 CSV | Classification of environmental conditions - Part 4-3: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Stationary use at weatherprotected locations |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60146-2:1999 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN ISO 7779:2010 | Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment (ISO 7779:2010) |
EN 60146-2:2000 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 62040-2:2006/corrigendum:2006 | |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
ISO 7779:2010 | Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.