• Shopping Cart
    There are no items in your cart

I.S. EN 62209-2:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODYMOUNTED WIRELESS COMMUNICATION DEVICES - HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES - PART 2: PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE (SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ)

Available format(s)

Hardcopy , PDF

Superseded date

24-07-2019

Language(s)

English

Published date

01-01-2010

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€149.00
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Measurement system specifications
6 Protocol for SAR evaluation
7 Uncertainty estimation
8 Measurement report
Annex A (informative) - Phantom rationale
Annex B (normative) - SAR measurement system verification
Annex C (informative) - Fast SAR testing
Annex D (informative) - Standard sources and phantoms
        for system validation
Annex E (informative) - Example recipes for phantom
        tissue-equivalent liquids
Annex F (normative) - SAR correction for deviations of
        complex permittivity from targets
Annex G (informative) - Hands-free kit testing
Annex H (informative) - Skin enhancement factor
Annex I (informative) - Tissue-equivalent liquid dielectric
        property measurements and measurement uncertainty
        estimation
Annex J (informative) - Testing compliance for the exposure
        of the hand
Annex K (informative) - Test reduction
Annex L (normative) - Power scaling procedure
Annex M (informative) - Rationale for probe parameters
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Pertains to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
118
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
IEC 62209-2:2010 Identical
EN 62209-2:2010 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
ISO/IEC Guide 51:2014 Safety aspects — Guidelines for their inclusion in standards
IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
IEC 62311:2007 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
EN 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.