I.S. EN 62209-2:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODYMOUNTED WIRELESS COMMUNICATION DEVICES - HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES - PART 2: PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE (SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ)
Hardcopy , PDF
24-07-2019
English
01-01-2010
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Measurement system specifications
6 Protocol for SAR evaluation
7 Uncertainty estimation
8 Measurement report
Annex A (informative) - Phantom rationale
Annex B (normative) - SAR measurement system verification
Annex C (informative) - Fast SAR testing
Annex D (informative) - Standard sources and phantoms
for system validation
Annex E (informative) - Example recipes for phantom
tissue-equivalent liquids
Annex F (normative) - SAR correction for deviations of
complex permittivity from targets
Annex G (informative) - Hands-free kit testing
Annex H (informative) - Skin enhancement factor
Annex I (informative) - Tissue-equivalent liquid dielectric
property measurements and measurement uncertainty
estimation
Annex J (informative) - Testing compliance for the exposure
of the hand
Annex K (informative) - Test reduction
Annex L (normative) - Power scaling procedure
Annex M (informative) - Rationale for probe parameters
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
118
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 62209-2:2010 | Identical |
EN 62209-2:2010 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
IEC 62479:2010 | Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEEE 1528-2013 REDLINE | IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques |
IEC 62311:2007 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
EN 62209-1:2016 | Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |