I.S. EN 62621:2016
Current
The latest, up-to-date edition.
RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
Hardcopy , PDF
English
01-01-2016
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Characteristics of composite insulators
for overhead contact line systems
5 Testing
6 Identification
7 Transport, storage, installation and maintenance
Annex A (informative) - Purchaser requirements
Annex B (informative) - Principles of the damage limit,
load coordination and testing
Annex C (informative) - Guidance on non-standard
mechanical stresses and dynamic mechanical loading
Annex D (informative) - Determination of the equivalent
bending moment caused by combined loads
Bibliography
Annex ZA (normative) - Normative references to
international publicationswith their
corresponding European publications
Annex ZZ (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 2008/57/EC
Defines characteristics for composite insulators of electric traction overhead contact line systems for railways, as defined in IEC 60913.
DevelopmentNote |
Supersedes I.S. EN 50151. (04/2016) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 62621:2016/A1:2016 | Identical |
IEC 60826:2017 | Design criteria of overhead transmission lines |
IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
ISO 34-1:2015 | Rubber, vulcanized or thermoplastic Determination of tear strength Part 1: Trouser, angle and crescent test pieces |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 60913:2013 | Railway applications - Fixed installations - Electric traction overhead contact lines |
EN 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
IEC 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
ISO 37:2017 | Rubber, vulcanized or thermoplastic — Determination of tensile stress-strain properties |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
EN 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
EN 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
EN 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.