Foreword
444 Measures against electromagnetic influences
444.0 Introduction
444.1 Scope
444.2 Normative references
444.3 Definitions
444.4 Mitigation of electromagnetic interference (EMI)
444.5 Earthing and equipotential bonding
444.6 Segregation of circuits
444.7 Cable management systems
444.Z1 Installations
Annex ZA (normative) Special national conditions
Bibliography
Gives requirements and recommendations for electrical installations in order to avoid or reduce the impact of electromagnetic disturbances.
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
HD 60364-4-444:2010/AC:2012 | Identical |
EN 60446:2007 | Basic and safety principles for man-machine interface, marking and identification - Identification of conductors by colours or alphanumerics |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
IEC 61663-1:1999 | Lightning protection - Telecommunication lines - Part 1: Fibre optic installations |
EN 61558-2-4:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers |
EN 60297-3-105:2009 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-105: Dimensions and design aspects for 1U high chassis |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN 62020:1998/A1:2005 | ELECTRICAL ACCESSORIES - RESIDUAL CURRENT MONITORS FOR HOUSEHOLD AND SIMILAR USES (RCMS) |
IEC 61558-2-15:2011 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61558-2-4:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60297-3-105:2008 | Mechanical structures for electronic equipment - Dimensions of mechanical structures of the 482,6 mm (19 in) series - Part 3-105: Dimensions and design aspects for 1U high chassis |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
EN 61558-2-15:2012 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations |
HD 60364-5-51:2009/A12:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 61663-1 : 1999 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1 - FIBRE OPTIC INSTALLATIONS |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
IEC 62020:1998+AMD1:2003 CSV | Electrical accessories - Residual current monitors for household and similar uses (RCMs) |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 300 253 : 2.2.1 | ENVIRONMENTAL ENGINEERING (EE); EARTHING AND BONDING OF ICT EQUIPMENT POWERED BY -48 VDC IN TELECOM AND DATA CENTRES |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
EN 50117-4-1 : 2008 AMD 1 2013 | COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.