IEC 60331-3:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-09-2022

Language(s)

English - French

Published date

19-05-2009

€155.95
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Test specimen (electric power and control cables with
   rated voltage up to and including 600 V/1000 V)
7 Test procedure (electric power and control cables
   with rated voltage up to and including 600 V/1000 V)
8 Performance requirements (electric power and control
   cables with rated voltage up to and including 600 V/1000 V)
9 Retest procedure
10 Test report (electric power and control cables with rated
   voltage up to and including 600 V/1000 V)
Annex A (normative) - Verification procedure for the
        source of heat
Annex B (informative) - Guidance on the choice of recommended
        test apparatus (burner And venturi)
Bibliography

IEC 60331-3:2009 specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which are required to maintain circuit integrity when tested in a metal enclosure and when subject to fire and mechanical shock under specified conditions. This standard describes the means of sample preparation, the continuity checking arrangements, the electrical testing procedure, the method of burning the cables and the method of shock production and gives requirements for evaluating test results. NOTE All cables assessed by this method should first have been assessed against the test of IEC 60331-1 or IEC 60331-2. Such performance may be recognized by the marking according to Clause 11 of IEC 60331-1 or Clause 11 of IEC 60331-2. Annex A provides the method of verification of the burner and control system used for the test. It has the status of a horizontal standard in accordance with IEC Guide 104.

Committee
TC 20
DevelopmentNote
Stability Date: 2023. (04/2018)
DocumentType
Standard
Pages
49
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
AS/NZS IEC 60331.3:2017 Identical
GOST IEC 60331-3 : 2013 Identical

BS EN 50553 : 2012 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 5266-1:2016 Emergency lighting Code of practice for the emergency lighting of premises
11/30227604 DC : 0 BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY ESCAPE LIGHTING OF PREMISES
I.S. EN 50553:2012 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
15/30325295 DC : 0 BS 8592 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED, FIRE-RESISTANT, SINGLE CORE NON-SHEATHED CABLES OF RATED VOLTAGE 450/750 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
BS 5266-1:2011 Emergency lighting Code of practice for the emergency escape lighting of premises
NF EN 50553 : 2012 AMD 1 2017 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
BS 8592:2016 Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification
16/30331553 DC : 0 BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY LIGHTING OF PREMISES
C22.2 NO. 245-17 Marine shipboard cable
EN 50553 : 2012 AMD 1 2016 RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

IEC 60331-2:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
IEC 60331-1:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
IEC 61034-1:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.